Pittsburgh 2.5 CFM 1/6 HP One Stage Bomba de buit

Pittsburgh 2.5 CFM 1/6 HP One Stage Manual d'usuari de la bomba de buit

Model: 2.5 CFM 1/6 HP One Stage Bomba de buit

Introducció

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump. Please read this manual thoroughly before operating the pump and retain it for future reference.

The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump is designed for deeper vacuum draw, pulling vacuum down to 75 microns. Its precision-machined one-stage pump effectively removes moisture from air conditioning systems, preparing them for safe refrigerant addition. This pump is ideal for automotive air conditioning, HVAC work, and other applications requiring high vacuum pull from a compact unit.

Informació important de seguretat

Always observe basic safety precautions when using this product to reduce the risk of personal injury and damage to equipment.

  • Llegiu totes les instruccions abans d'utilitzar.
  • Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi ulleres i guants de seguretat.
  • Assegureu-vos que la zona de treball estigui ben ventilada.
  • No feu funcionar la bomba en condicions humides ni l'exposeu a la pluja.
  • Desconnecteu l'alimentació abans de realitzar qualsevol manteniment o servei.
  • Use only with specified refrigerants (R134A, R12, R22).

Configuració

Before initial operation, ensure the vacuum pump is placed on a stable, level surface. Check the oil level and fill if necessary with appropriate vacuum pump oil.

Initial Oil Fill/Check

  1. Locate the oil fill cap and sight glass on the pump.
  2. Desenrosqueu el tap d'ompliment d'oli.
  3. Pour vacuum pump oil into the fill port until the oil level is visible in the sight glass, reaching the indicated fill line. Do not overfill.
  4. Torneu a col·locar el tap d'ompliment d'oli de manera segura.

Connecting to an HVAC System

The pump features dual ports for R134A and R12/R22 systems. Use appropriate manifold gauges and hoses for connection.

Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump connected to an HVAC system with manifold gauges.

Figura 1: The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump connected to an HVAC system. The image shows the vacuum pump on a wooden deck, connected via yellow and blue hoses to a manifold gauge set. The manifold gauge set is then connected to an outdoor HVAC unit. This setup illustrates a typical vacuuming process for an air conditioning system.

  1. Assegureu-vos que totes les vàlvules del conjunt de manòmetres del col·lector estiguin tancades.
  2. Connect the appropriate vacuum hose from the manifold gauge set to the vacuum pump's inlet port.
  3. Connect the manifold gauge set to the service ports of the HVAC system.
  4. Comproveu que totes les connexions estiguin ajustades per evitar fuites.

Instruccions de funcionament

Follow these steps for proper operation of the vacuum pump to evacuate an HVAC system.

  1. With the pump connected to the system and manifold gauges, open the manifold gauge valves to the system.
  2. Plug the vacuum pump into a grounded electrical outlet.
  3. Turn on the vacuum pump. The pump will begin to pull a vacuum on the system.
  4. Monitor the vacuum gauge on your manifold set. Allow the pump to run until the desired vacuum level (e.g., 75 microns or lower) is achieved and held steady for a specified period (e.g., 15-30 minutes) to ensure all moisture is removed.
  5. Once the desired vacuum is reached, close the manifold gauge valves to isolate the system from the pump.
  6. Turn off the vacuum pump and then disconnect it from the manifold gauges.
  7. Proceed with refrigerant charging as per HVAC system manufacturer's instructions.

Manteniment

Un manteniment regular garanteix la longevitat i el rendiment òptim de la bomba de buit.

Canvi d'oli

Vacuum pump oil should be changed frequently, especially after each use on a contaminated system or when the oil appears cloudy or discolored. Contaminated oil reduces the pump's ability to pull a deep vacuum.

  1. Ensure the pump is off and unplugged.
  2. Col·loqueu un recipient adequat sota el tap de drenatge d'oli.
  3. Traieu el tap de drenatge d'oli i deixeu que tot l'oli vell s'escorri completament.
  4. Substituïu el tap de drenatge d'oli de manera segura.
  5. Refill with new, clean vacuum pump oil as described in the "Initial Oil Fill/Check" section.

Neteja general

Keep the exterior of the pump clean and free of debris. Do not use harsh chemicals or solvents that could damage the housing.

Resolució de problemes

This section addresses common issues you might encounter with your vacuum pump.

ProblemaCausa possibleSolució
La bomba no arrencaNo power; Thermal overload tripped; Motor fault.Check power connection and outlet; Allow pump to cool down; Consult qualified technician.
La bomba no fa prou buitLow or contaminated oil; Leaks in system/hoses; Clogged inlet filter.Change oil; Check all connections for leaks; Clean/replace inlet filter.
Excés de soroll/vibracióLow oil level; Damaged internal components.Check and add oil; Contact customer support for service.

Especificacions

Key technical specifications for the Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump:

  • Aplicació: R134A, R12, R22 refrigerant
  • Caudal: 2.5 CFM
  • Horsepower (hp): 1 / 6 HP
  • Buit màxim: 75 micres (10 Pascals)
  • Alçada del producte: 9 polzades.
  • Durada del producte: 11-1/4 polzades.
  • Amplada del producte: 4-3/4 polzades.
  • Pes: 18.25 lliures.
  • Mida del fil: 1/4 in. SAE & 1/2 in.
  • Material de l'habitatge: Durable die cast aluminum
  • Protecció: Thermal and current overload protection

Garantia i Suport

Per obtenir informació sobre la garantia o assistència tècnica, consulteu el lloc web oficial del fabricant. weblloc web o poseu-vos en contacte amb el seu departament d'atenció al client. Conserveu el rebut de compra per a reclamacions de garantia.

Fabricant: Pittsburgh

ASIN: B006ZBAXSW

Data de primera disponibilitat: 4 de maig de 2014

Per obtenir ajuda addicional, podeu visitar el product page on Amazon.com.

Documents relacionats - 2.5 CFM 1/6 HP One Stage Bomba de buit

Preview Pittsburgh A/C Manifold Gauge Set Owner's Manual & Safety Instructions
This manual provides safety instructions, specifications, applications, operation, and maintenance for the Pittsburgh A/C Manifold Gauge Set. It details how to safely use the gauge set for automotive air conditioning systems, including procedures for diagnostic checks, recovery/evacuation, and charging.
Preview Manual del propietari i instruccions de seguretat del kit d'eines de doble abaixament de Pittsburgh
Aquest manual proporciona avisos de seguretat, procediments de muntatge, funcionament, inspecció, manteniment i neteja per al kit d'eines de doble abaixament Pittsburgh. Inclou especificacions, informació important de seguretat, instruccions de funcionament, pautes de manteniment i servei, i una llista de peces i un diagrama.
Preview Manual d'usuari i instruccions de seguretat del calibre digital compost PITTSBURGH de 6 polzades
Aquest manual proporciona avisos de seguretat, precaucions, procediments de muntatge, funcionament, inspecció, manteniment i neteja del calibre digital compost PITTSBURGH de 6 polzades. Inclou informació important de seguretat, descripcions dels components, instruccions de funcionament i detalls de la garantia.
Preview Inflador de pneumàtics Pittsburgh Dual Power Home 120V/Auto 12V amb llum LED: manual d'usuari i instruccions de seguretat
Manual d'usuari complet i instruccions de seguretat per a l'inflador de pneumàtics Pittsburgh Dual Power Home 120V/Auto 12V amb llum LED. Cobreix informació sobre el funcionament, el manteniment, la resolució de problemes i la garantia.
Preview Manual d'usuari i instruccions de seguretat de l'extractor de tres mordasses Pittsburgh de 8"
Manual del propietari i instruccions de seguretat per a l'extractor de tres mordasses Pittsburgh de 8 polzades (model 63952). Inclou informació sobre la configuració, el muntatge, els procediments d'operació, el manteniment, la llista de peces i la garantia de Harbor Freight Tools.
Preview Gato hidràulic de Pittsburgh: instruccions importants prèvies a l'operació
Llegiu aquestes instruccions crítiques prèvies al funcionament dels gats hidràulics de Pittsburgh per garantir un ús segur i correcte. Inclou dades de contacte per a l'assistència tècnica.