1. Introducció
This user manual provides comprehensive instructions for the installation, operation, and maintenance of your Danfoss RET electronic thermostat. Designed for 230V fan coil units, this thermostat offers precise temperature control with hot/cold switching capabilities.
Please read this manual carefully before installation and use to ensure safe and efficient operation of the device.
2. Producte acabatview

Figure 2.1: Danfoss RET Electronic Thermostat
This image displays the front of the Danfoss RET electronic thermostat. It features a prominent central rotary dial for setting the desired temperature, marked with numerical values (e.g., 10, 20, 30) and small dots indicating intermediate settings. To the left of the dial, there are symbols for heating (snowflake/star), off (circle), and fan speed (three wavy lines). To the right, there are symbols for fan speed control (three fan icons with horizontal lines). The Danfoss logo is visible at the bottom center. The thermostat is white with grey markings.
Característiques principals:
- Designed for 3-speed fan coil units.
- Powered output for 230V speed control and electrothermal head.
- Integrated Hot / Off / Cold switch for mode selection.
- Model Type: RET230CO3.
- Power Supply: 230V AC Mains.
3. Especificacions tècniques
| Característica | Especificació |
|---|---|
| Marca | Danfoss |
| Número de model | 087N7032 (RET230CO3) |
| Voltage | 230 Volts |
| Llum de fons | Sí |
| ASIN | B007C1SAA2 |
| Codi Internacional d'Articles (EAN) | 05013567873272 |
4. Instal·lació i configuració
Important: Installation must be carried out by a qualified electrician and in accordance with all local electrical codes and regulations. Ensure the main power supply is disconnected before commencing any installation work.
4.1 Ubicació de muntatge
- Mount the thermostat on an interior wall, approximately 1.5 meters (5 feet) above the floor.
- Eviteu llocs propers a fonts de calor (per exemple, llum solar directa,amps, appliances) or drafts (e.g., windows, doors, air vents) that could affect temperature readings.
- Ensure adequate air circulation around the thermostat.
4.2 Instruccions de cablejat
Refer to the wiring diagram provided with the product packaging for specific connections. General wiring steps include:
- Disconnect power to the fan coil unit circuit at the main breaker.
- Remove the front cover of the thermostat.
- Connect the 230V AC mains supply to the designated terminals (L and N).
- Connect the fan speed control wires (typically Low, Medium, High) and the electrothermal head control wire to their respective terminals as per the diagram.
- Secure all wiring connections firmly.
- Torneu a col·locar la tapa frontal.
- Resta l'alimentació del circuit.
5. Funcionament
5.1 Mode Selection (Hot / Off / Cold Switch)
The thermostat features a three-position switch on the side or front for selecting the operating mode:
- Hot (Heating Mode): Select this position for heating. The thermostat will activate the heating function when the room temperature falls below the setpoint.
- Apagat: Select this position to turn off both heating and cooling functions. The fan may still operate depending on the fan speed setting.
- Cold (Cooling Mode): Select this position for cooling. The thermostat will activate the cooling function when the room temperature rises above the setpoint.
5.2 Ajust de temperatura
Adjust the desired room temperature using the large central rotary dial. Rotate the dial clockwise to increase the setpoint temperature and counter-clockwise to decrease it. The numbers on the dial indicate temperature in degrees Celsius.
5.3 Control de velocitat del ventilador
The thermostat allows control of the fan coil unit's fan speed. Use the fan speed selector (usually a switch or buttons) to choose between:
- Velocitat baixa
- Velocitat mitjana
- Alta Velocitat
- Auto (if available): The thermostat automatically adjusts fan speed based on the temperature difference.
6. Manteniment
The Danfoss RET thermostat requires minimal maintenance. Regular cleaning can help ensure optimal performance.
6.1 Neteja
- Before cleaning, ensure the power supply to the thermostat is disconnected.
- Netegeu l'exterior del termostat amb un drap suau i sec.amp tela.
- Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the surface or internal components.
- Assegureu-vos que no entri humitat als components interns del termòstat.
6.2 Cura del sensor
Keep the thermostat's vents and openings clear of dust and debris to ensure accurate temperature sensing. Do not obstruct the airflow around the unit.
7. Solució De Problemes
If you experience issues with your Danfoss RET thermostat, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| El termòstat no s'encén. | No power supply; loose wiring; tripped circuit breaker. | Check circuit breaker. Ensure wiring is secure. Consult a qualified electrician if issues persist. |
| Heating/Cooling not activating. | Incorrect mode selected (Hot/Off/Cold); temperature setpoint not met; fan coil unit issue. | Verify mode switch position. Adjust setpoint. Check fan coil unit's power and operation. |
| Lectura de temperatura inexacta. | Thermostat located near heat source/draft; obstructed sensor. | Relocate thermostat if possible. Clear any obstructions around the unit. |
| Fan not operating at selected speed. | Incorrect fan speed setting; fan coil unit fan motor issue. | Ensure correct fan speed is selected. Consult fan coil unit manual or technician. |
If the problem persists after attempting these solutions, please contact Danfoss customer support or a qualified service technician.
8. Garantia i Suport
Specific warranty information for the Danfoss RET230CO3 thermostat is typically provided with the product packaging or can be found on the official Danfoss weblloc web. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.
For technical support, spare parts, or service inquiries, please visit the official Danfoss website or contact their customer service department. Contact details can usually be found on the product packaging or the Danfoss weblloc.