1. Introducció
This manual provides essential instructions for the installation, operation, and maintenance of your DSC TYCO Alarm System PC1832 with PK5501 Keypad. This system is designed to provide reliable security for your property. Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and safety.
2. Informació de seguretat
- Seguretat elèctrica: Ensure all power connections are made by qualified personnel. Disconnect power before servicing the system.
- Manipulació de la bateria: The system includes a 12V battery. Handle with care and dispose of old batteries according to local regulations. Do not short-circuit battery terminals.
- Col·locació del sistema: Install components in locations that are dry and free from extreme temperatures or direct sunlight.
- Instal·lació professional recomanada: While this manual provides guidance, professional installation is highly recommended for optimal system performance and compliance with local codes.
3. Components inclosos
Your DSC TYCO Alarm System kit includes the following components:
- DSC PC1832 Control Panel with Metal Box
- DSC PK5501 Keypad
- DSC LC-100-PI PIR Motion Detector
- DSC Siren
- DSC PTC1640U Transformer
- DSC 12V Battery
- Jack de telèfon

This image displays the complete kit for the DSC TYCO Alarm System PC1832. Visible components include the main control panel in a metal box, the PK5501 keypad with a digital display, a DSC LC-100-PI PIR motion detector, a 12V battery, a PTC1640U transformer, a DSC siren, and a phone jack.
4. Configuració
The DSC PC1832 alarm system requires careful installation. It supports 8 hardwired zones and is expandable up to 32 zones using PC5108 zone expanders or up to 32 wireless zones.
4.1 Control Panel Installation
- Muntatge: Securely mount the metal control panel box in a discreet, central location, away from moisture and extreme temperatures.
- Cablejat: Connect all hardwired zones (e.g., door/window contacts, motion detectors) to the appropriate terminals on the PC1832 panel. Refer to the detailed wiring diagrams in the installer manual for specific connections.
- Connexió d'alimentació: Connect the PTC1640U transformer to the panel's AC terminals. Connect the 12V battery to the battery terminals, ensuring correct polarity. The battery provides backup power during outages.
- Siren Connection: Connect the DSC siren to the designated siren output terminals.
- Phone Line Connection: If using a landline for monitoring, connect the phone jack to the panel's communication terminals.
4.2 Keypad (PK5501) Installation
- Mount the PK5501 keypad in a convenient location near an entry/exit point.
- Connect the keypad to the control panel's Keybus terminals (Red, Black, Yellow, Green).
4.3 Sensor Installation (LC-100-PI PIR)
- Mount the LC-100-PI PIR motion detector in a corner or on a wall, ensuring it covers the desired area without obstructions. Avoid aiming it at heat sources or windows.
- Connect the PIR to a designated zone on the control panel.
4.4 Programació inicial
After physical installation, the system requires programming. This typically involves defining zones, setting user codes, and configuring communication options. The default installer code is often 5555. To enter programming mode, press * aleshores 8, followed by the installer code.
5. Instruccions de funcionament
5.1 Armar el sistema
- Braç lluny: To arm the system when leaving the premises, ensure all zones are closed (no faults displayed on the keypad). Enter your 4-digit or 6-digit user code. The keypad will indicate 'Armed' and start the exit delay.
- Estada del braç: To arm the system while remaining inside (bypassing interior zones like motion detectors), press * aleshores 9, followed by your user code.
5.2 Desarmament del sistema
- Upon entering the premises, the keypad will begin the entry delay. Enter your 4-digit or 6-digit user code to disarm the system before the delay expires.
5.3 Bypassing Zones
To temporarily bypass a specific zone (e.g., a window left open), press * aleshores 1, enter the 2-digit zone number, and then your user code. The keypad will confirm the bypass. Bypassed zones are automatically unbypassed when the system is disarmed.
5.4 Changing User Codes
To change a user code, press * aleshores 5, enter your Master Code, then the 2-digit user number (01-32), and finally the new 4-digit or 6-digit code.
6. Manteniment
6.1 Substitució de la bateria
The 12V system battery should be replaced approximately every 3-5 years, or when a 'Low Battery' trouble condition is indicated on the keypad. Disconnect AC power before replacing the battery. Ensure the replacement battery is of the same type and rating.
6.2 Neteja del sensor
Periodically clean the lens of the LC-100-PI PIR motion detector with a soft, dry cloth to ensure optimal performance and prevent false alarms caused by dust or debris.
6.3 Prova del sistema
It is recommended to test your alarm system monthly. To perform a system test, refer to your installer manual or contact your alarm monitoring company for specific instructions. This typically involves arming the system and triggering each zone to ensure proper reporting.
7. Solució De Problemes
This section addresses common issues you might encounter with your DSC TYCO Alarm System.
- Keypad Displays 'Trouble': Premeu * aleshores 2 a view the trouble condition. Common troubles include low battery, AC failure, or zone faults.
- Falses alarmes: Check for open windows/doors, pets triggering motion detectors, or environmental factors like drafts or direct sunlight on sensors. Ensure motion detectors are clean.
- System Not Arming: Verify all zones are closed. The keypad will display open zones. Close them or bypass them if necessary.
- Lost Installer Code: If the installer code is lost and you cannot access programming, a factory reset might be required, which should only be performed by a qualified technician.
- No Dial Tone/Communication Failure: Check phone line connections and ensure the phone jack is properly installed.
For complex issues or programming difficulties, consult the full DSC PC1832 Installer Manual or contact a professional alarm technician.
8. Especificacions
| Marca | DSC |
| Número de model | ESM-ALAKIT-96 (PC1832 System) |
| Tecnologia de connectivitat | Wired, Wireless (expandable) |
| Font d'alimentació | Battery Powered (with AC transformer) |
| Voltage | 12 Volts |
| Composició de les cèl·lules de la bateria | Àcid de plom |
| Components inclosos | PC1832 Panel, PK5501 Keypad, LC-100-PI PIR, Siren, Transformer, 12V Battery, Phone Jack |
| Dispositius compatibles | Door/Window Contactor, Motion Detector Sensors, Glass Break Sensors, Carbon Monoxide Detectors, Smoke Detectors, Heat Detectors, Low/High Temperature Sensors |
9. Garantia i Suport
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your authorized DSC dealer or the seller directly. Keep your proof of purchase for warranty claims.