Producte acabatview
The 3M Cold Shrink QT-II Silicone Rubber Termination Kit 5614A is designed for non-shielded electrical applications, specifically for 5 kV and 8 kV systems with conductor sizes ranging from 350-1000 KCMIL. This kit provides a reliable and durable termination solution for electrical cables, utilizing cold shrink technology for easy and consistent installation without the need for heat or special tools.

Image: A single component of the 3M Cold Shrink QT-II Silicone Rubber Termination Kit, showing its cylindrical shape and grey silicone material.
Informació de seguretat
Always adhere to local electrical codes and safety regulations when installing or working with electrical components. Failure to do so may result in serious injury or property damage.
- Ensure power is disconnected and locked out before beginning any installation.
- Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi guants aïllants i ulleres de seguretat.
- Only qualified personnel should perform electrical installations.
- Inspect all kit components for damage before use. Do not use damaged components.
- Mantenir la zona de treball neta i lliure de residus.
Contingut del kit
Each 3M Cold Shrink QT-II Silicone Rubber Termination Kit 5614A typically includes the following components necessary for terminating three cables:
- Three (3) Cold Shrink Silicone Rubber Terminations
- Grounding components (e.g., copper braid, constant force springs)
- Mastic sealing tapes
- Instruccions d'instal·lació

Image: The complete 3M Cold Shrink QT-II Silicone Rubber Termination Kit, showing three cold shrink tubes and a box of Scotch self-fusing silicone electrical tape.
Muntatge i preparació
Preparació de l'àrea de treball
- Ensure the work area is clean, dry, and well-lit.
- Verify that the cable to be terminated is de-energized and properly grounded.
- Gather all necessary tools, including cable strippers, crimpers, cleaning solvents, and measuring tape.
Preparació del cable
- Measure and cut the cable to the required length, ensuring sufficient slack for termination.
- Remove the outer jacket of the cable according to the specific dimensions provided in the kit's detailed instructions (refer to the included manual for precise measurements).
- Prepare the cable insulation and conductor as per standard electrical practices and kit instructions, including cleaning and deburring.
- Install the appropriate lug or connector onto the conductor, ensuring a secure and proper crimp.
Operating Instructions: Installation Procedure
The cold shrink technology simplifies installation by eliminating the need for heat. Follow these general steps, always referring to the detailed instructions included with your kit for specific dimensions and techniques.
- Clean and Prepare: Thoroughly clean the prepared cable insulation and lug with an appropriate solvent and allow to dry.
- Position Termination: Carefully slide the cold shrink termination tube over the prepared cable end and onto the lug. Ensure the termination is correctly aligned and positioned over the stress cone area.
- Elimina el nucli: Locate the plastic core inside the cold shrink tube. Begin unwinding the core from one end, pulling it out slowly and steadily. As the core is removed, the silicone rubber tube will shrink tightly onto the cable and lug, forming a seal.
- Grounding (if applicable): Install any necessary grounding components (e.g., copper braid, constant force springs) as specified in the kit instructions.
- Segell (si escau): Apply any mastic sealing tapes or additional sealing materials as directed by the kit instructions to ensure a moisture-tight seal.
- Inspeccionar: Visually inspect the installed termination to ensure it is fully shrunk, properly seated, and free from any defects or voids.
This kit is specifically designed for splicing and terminating electrical cables, providing insulation and environmental sealing for medium voltage aplicacions.
Manteniment
The 3M Cold Shrink QT-II Silicone Rubber Termination Kit is designed for long-term, maintenance-free operation once properly installed. Regular maintenance is generally not required for the termination itself.
- Inspecció periòdica: Periodically inspect the installed terminations for any signs of physical damage, cracking, or environmental degradation.
- Factors ambientals: Ensure the termination area remains free from excessive moisture, dirt, or corrosive substances that could compromise its integrity over time.
- Neteja: If necessary, gently clean the exterior of the termination with a soft, damp tela. Eviteu utilitzar productes químics o materials abrasius.
Resolució de problemes
While cold shrink terminations are generally reliable, issues can arise from improper installation or environmental factors. Here are some common concerns:
- Incomplete Shrinkage: If the termination does not fully shrink, it may indicate that the plastic core was pulled too quickly or unevenly, or that the cable diameter is outside the specified range. Ensure slow, steady removal of the core.
- Voids or Gaps: Voids can occur if the cable preparation was not smooth or if the termination was not properly positioned. Re-installation may be necessary if voids compromise insulation.
- Damage During Installation: Avoid sharp objects or excessive force that could puncture or tear the silicone rubber. If damaged, the termination must be replaced.
- Environmental Degradation: Over time, extreme UV exposure or chemical contamination can affect the material. Ensure proper environmental protection if installed in harsh conditions.
For persistent issues, consult a qualified electrician or contact 3M technical support.
Especificacions
| Atribut | Detall |
|---|---|
| Fabricant | 3M |
| Número de part | 5614A |
| Número de model de l'article | 5614A |
| Pes de l'article | 1.4 lliures |
| Dimensions del producte | 7.5 x 12.5 x 4.5 polzades |
| Color | Negre |
| Acabar | Negre |
| Material | silici |
| Font d'alimentació | wired electric (Context: for the application, not the kit itself) |
| Quantitat de paquet d'articles | 1 (Kit contains multiple components for 3 terminations) |
| Nombre de peces | 1 (Refers to the kit as one unit) |
| Components inclosos | INDOOR AND OUTDOOR TERMINATION KIT |
| Necessites piles? | No |
| Voltage Classificació | 5 kV i 8 kV |
| Conductor Size Range | 350-1000 KCMIL |
Garantia i Suport
3M products are manufactured to high standards. For specific warranty information regarding the 3M Cold Shrink QT-II Silicone Rubber Termination Kit 5614A, please refer to the documentation included with your purchase or visit the official 3M weblloc.
For technical assistance, product inquiries, or support, please contact 3M customer service directly. You can often find contact information on the product packaging or on the 3M official weblloc.
While protection plans are available from third-party sellers, these are separate from the manufacturer's warranty. Examples include 3-Year Protection Plan and 4-Year Protection Plan options.
Recursos en línia:
- Visita el Botiga 3M a Amazon per a més productes i informació.