1. Introducció
1.1 Producte acabatview
The Watt Stopper DT-300 is a dual technology ceiling occupancy sensor designed to automatically control lighting based on occupancy detection. It integrates both Passive Infrared (PIR) and Ultrasonic technologies to provide comprehensive coverage and reliable performance. This sensor is suitable for various commercial and institutional applications, ensuring energy savings by turning lights off when spaces are unoccupied.

Figure 1: Watt Stopper DT-300 Ceiling Occupancy Sensor, front view.
1.2 Característiques clau
- Tecnologia dual: Combines PIR and Ultrasonic for enhanced detection accuracy.
- Cobertura de 360 graus: Provides wide area detection from a ceiling mount.
- Pro baixfile Disseny: Architecturally appealing and unobtrusive appearance.
- SmartSet Technology: Automatically selects optimal settings for various spaces.
- Manual-On Capability: Accepts low voltage switch input for manual activation.
- Depluggable Terminal Wiring: Facilitates quick and easy installation.
- Mode de recorregut: Increases energy savings potential.
- Isolated Relay: Allows interface with Building Control Systems (BAS) and HVAC systems.
- Certificacions: UL and cUL listed for safety and performance.
2. Instal·lació i configuració
2.1 Components
The DT-300 sensor typically consists of the sensor head and a power pack (e.g., BZ-50). Ensure all components are present before beginning installation.

Figure 2: DT-300 Sensor (left) and BZ-50 Power Pack (right).

Figura 3: posterior view of the DT-300 sensor showing the depluggable terminal block, alongside the BZ-50 power pack.
2.2 Esquema de cablejat
Proper wiring is crucial for the sensor's functionality. Refer to the diagram below for connecting the DT-300 sensor to its power pack and the lighting load. Always ensure power is disconnected before performing any wiring.

Figure 4: Detailed wiring diagram for the BZ-50 Power Pack, illustrating connections to the DT-300 sensor, lighting load, and power source.
2.3 Instruccions de muntatge
- Seleccioneu la ubicació: Choose a central ceiling location within the desired coverage area (up to 1000 sq ft). Avoid placing near HVAC vents or direct sunlight, which can affect sensor performance.
- Preparació de l'obertura: Create an appropriate opening in the ceiling for the sensor and power pack.
- Connecteu el cablejat: Follow the wiring diagram (Figure 4) to connect the sensor to the power pack and the power pack to the building's electrical system and lighting load.
- Muntatge del sensor: Secure the DT-300 sensor into the ceiling opening.
- Mount Power Pack: Secure the power pack in an accessible location, typically above the ceiling or in a junction box.
- Restaura l'alimentació: Un cop totes les connexions estiguin segures i verificades, restableu l'alimentació del circuit.
3. Funcionament
3.1 Dual Technology Detection
The DT-300 sensor utilizes both PIR and Ultrasonic technologies. Lighting will turn on when tots dos technologies detect occupancy. Once the lights are on, detection by tampoc technology is sufficient to keep the lights on. This dual detection method helps minimize false triggers and ensures reliable occupancy sensing.
3.2 Manual-On Operation
The sensor supports manual-on operation via a low voltage switch. If a switch is connected, users can manually turn on the lights. The sensor will then maintain the lights based on occupancy detection, turning them off after the set time delay when no occupancy is detected.
3.3 Time Delay and Walk-Through Mode
The sensor features an adjustable time delay, which determines how long the lights remain on after the last detected occupancy. The Walk-Through Mode is an energy-saving feature that reduces the time delay if a person quickly enters and exits the space, preventing the lights from staying on unnecessarily.
4. Manteniment
4.1 Neteja
To ensure optimal performance, periodically clean the sensor lens and housing with a soft, dry cloth. Avoid using abrasive cleaners or solvents, as these can damage the sensor's components.
4.2 Sensor Checks
Regularly verify the sensor's detection capabilities by walking through the coverage area. If the sensor is not responding as expected, refer to the troubleshooting section. No specific calibration is typically required for this model under normal operating conditions.
5. Solució De Problemes
5.1 Problemes comuns i solucions
| Problema | Causa possible | Solució |
|---|---|---|
| Lights do not turn on with occupancy. | No power to sensor/power pack; incorrect wiring; sensor lens obstructed; sensitivity too low. | Check circuit breaker; verify wiring connections; clear obstructions; adjust sensor sensitivity. |
| Lights remain on despite no occupancy. | Time delay set too long; constant motion in coverage area; sensor detecting HVAC movement. | Adjust time delay setting; ensure no constant motion sources; reposition sensor if necessary. |
| Lights turn off too quickly. | Time delay set too short; sensor sensitivity too low; Walk-Through Mode active. | Increase time delay; adjust sensor sensitivity; review Walk-Through Mode settings. |
6. Especificacions tècniques
6.1 Especificacions generals
- Model: DT-300
- Marca: Watt Stopper
- Tecnologia: Dual (Passive Infrared & Ultrasonic)
- Tipus de muntatge: Muntatge al sostre
- Àrea de cobertura: Up to 1000 sq ft (360 degrees)
- Font d'alimentació: Corded Electric (requires compatible power pack)
- Color: Blanc
- Dimensions del producte: 4.5"D x 4.5"W x 1.02"H (114.3mm diameter x 25.9mm deep)
- Pes de l'article: 6.4 unces
- Certificacions: Llistat UL, cUL
- Dispositius compatibles: Lighting Controls, Building Automation Systems (BAS), HVAC Systems
- UPC: 754182913824
6.2 Ambiental
- Temperatura de funcionament: 32 Degrees Fahrenheit (Note: This value typically represents a minimum; refer to full product datasheet for complete range.)
7. Garantia i atenció al client
7.1 Informació de la garantia
The Watt Stopper DT-300 Ceiling Occupancy Sensor comes with a Garantia limitada de cinc anys from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the official warranty documentation provided with your product or visit the manufacturer's weblloc.
7.2 Informació de contacte
For technical assistance, warranty claims, or further product information, please contact Watt Stopper customer support:
- Weblloc: www.wattstopper.com
- Telèfon: 800-879-8585