1. Introducció
The Hanna Instruments HI9147-04 is a water-resistant dissolved oxygen (DO) meter designed for aquaculture applications. It provides accurate measurements of dissolved oxygen in water, crucial for monitoring water quality and supporting aquatic life.
Key features include automatic temperature compensation, manual salinity and altitude compensation, a backlit LCD screen for clear readings, and a galvanic DO probe with a 4-meter cable that requires no conditioning time, allowing for quick measurements.

Image shows the Hanna Instruments HI9147-04 dissolved oxygen meter. The main unit is black with a digital display showing '10.0 mg/L', '60.8 °F', and '9.7 g/L Salinity'. Below the display are six circular buttons: On/Off, CAL, %, BL ▲, SAL, mg/L, and °C/°F ▼. A galvanic probe with a 4-meter cable is connected to the right side of the meter.
2. Què hi ha a la caixa
Upon unpacking your HI9147-04 Dissolved Oxygen Meter, please verify that all items are present and in good condition:
- HI9147-04 Dissolved Oxygen Meter
- HI 76409/4 probe with 4m (13’) cable
- (2) Spare membranes
- HI 7042S electrolyte solution (30 mL bottle)
- (3) Bateries AAA de 1.5 V
- HI 710016 shockproof rubber boot
- Tornavís
- Manual d'instruccions
3. Configuració
3.1 Instal·lació de la bateria
The meter operates on three 1.5V AAA batteries. To install or replace batteries:
- Localitzeu el compartiment de la bateria a la part posterior del mesurador.
- Obriu la tapa del compartiment de la bateria.
- Introduïu les tres piles AAA d'1.5 V, assegurant-vos de la polaritat correcta tal com s'indica a l'interior del compartiment.
- Tanqueu de manera segura la tapa del compartiment de la bateria.
3.2 Connexió de la sonda
Connect the galvanic DO probe to the designated port on the top right side of the meter. Ensure a secure connection to prevent water ingress and ensure proper electrical contact.
3.3 Calibratge inicial
Before first use and periodically, calibrate the meter for accurate readings. Calibration should be performed in air.
- Enceneu el comptador.
- Premeu el botó CAL button. The '%' indicator on the display will blink.
- With the probe exposed to air (not immersed in water), turn the trimmer (usually a small screw on the meter) until the display reads 100%.
- Premeu el botó CAL button again to confirm the calibration. The meter is now calibrated.
4. Funcionament
4.1 Engegada/apagada
Premeu el botó On/Off button located on the meter's keypad to power the device on or off.
4.2 Prendre mesures
To take a dissolved oxygen measurement:
- Assegureu-vos que el mesurador estigui calibrat.
- Submergeix la sonda al sample water. Ensure the membrane is fully submerged and there are no air bubbles trapped around it.
- Allow sufficient time for the reading on the display to stabilize before recording the measurement.
4.3 Compensation Settings
The HI9147-04 offers compensation features for accurate readings in various conditions:
- Compensació de salinitat: Premeu el botó SAL button to manually adjust for salinity. Refer to your sample's known salinity for accurate readings.
- Compensació d’altitud: The meter features manual altitude compensation. Adjust this setting based on your operating altitude for precise measurements. Consult the full manual for detailed instructions on setting altitude.
- Compensació de temperatura: The meter automatically compensates for temperature variations, ensuring accurate DO readings across different temperatures.
4.4 Selecció d'unitats
You can switch between different measurement units:
- Premeu el botó mg/L button to toggle between dissolved oxygen concentration in mg/L (parts per million, ppm) and % saturation.
- Premeu el botó °C/°F ▼ button to toggle between Celsius and Fahrenheit temperature units.
5. Manteniment
5.1 Cura de la sonda
To ensure the longevity and accuracy of your DO probe:
- Keep the probe membrane clean and free from debris.
- Rinse the probe with distilled or deionized water after each use.
- Store the probe properly, typically with the protective cap filled with electrolyte solution, to keep the membrane hydrated.
5.2 Membrane Replacement
The probe membrane should be replaced periodically or if it becomes damaged, scratched, or fouled. Refer to the included spare membranes and the detailed instructions provided with the probe for proper replacement procedures.
5.3 Electrolyte Solution Refill
Ensure the probe is filled with the HI 7042S electrolyte solution. The electrolyte solution needs to be replaced when the membrane is changed or if it becomes contaminated. Refill as needed, following the specific instructions for the probe.
5.4 Neteja del mesurador
Wipe the meter's exterior with a damp cloth. Do not use abrasive cleaners, solvents, or immerse the meter in water, as it is water-resistant but not fully submersible.
6. Solució De Problemes
If you encounter issues with your HI9147-04 meter, refer to the following common problems and solutions:
- Lectures inexactes o inestables:
- Ensure the probe is clean and properly calibrated.
- Check the electrolyte solution level and membrane condition; replace if necessary.
- Verify that salinity and altitude compensation settings are correct for your sample.
- Allow sufficient time for the probe to stabilize in the sample.
- Difficulty Calibrating:
- Confirm the probe is in air during calibration.
- Ensure the trimmer is adjusted correctly to reach 100%.
- If issues persist, check the probe membrane and electrolyte solution for contamination or depletion.
- Meter Not Powering On:
- Comproveu la instal·lació de les piles i assegureu-vos que no estiguin esgotades. Substituïu les piles si cal.
- Assegureu-vos que el compartiment de la bateria estigui ben tancat.
- Damaged Cable:
- Inspect the probe cable for any visible damage, kinks, or breaks.
- A damaged cable may require probe replacement to restore functionality.
7. Especificacions
| Paràmetre | Valor |
|---|---|
| Interval | 0.0 to 50.0 mg/L (ppm) O2, 0 to 600% O2, -5.0 to 50.0 °C |
| Resolució | 0.1 mg/L or 1% (O2) / 0.1 °C |
| Precisió | ±1% of reading (O2) / ±0.2 °C |
| Font d'alimentació | Three 1.5V AAA batteries (included) |
| Dimensions | 164 x 76 x 45mm / 6.5 x 3.0 x 1.8 inches (H x W x D) |
| Weight (with HI 76409/4 probe) | 511 g / 1.12 lliures |
| Número de model de l'article | HI9147-04 |
| ASIN | B0085X2GZ6 |
| Fabricant | Hanna Instruments |
8. Informació de la garantia
This Hanna Instruments product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, including duration and coverage details, please refer to the warranty documentation included with your product or visit the official Hanna Instruments weblloc web. Conserveu el comprovant de compra per a reclamacions de garantia.
9. Suport i informació de contacte
For further assistance, technical support, or to purchase accessories and replacement parts, please visit the official Hanna Instruments weblloc web o poseu-vos en contacte amb el seu departament d'atenció al client:
Hanna Instruments Store: Visit Hanna Instruments Store on Amazon
For direct support, please refer to the contact information provided in your product's packaging or on the main Hanna Instruments corporate weblloc.