1. Introducció
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vortice Record Extractor Fan M10/4T 100mm with Timer. This unit is designed for intermittent or continuous ventilation in small to medium domestic or commercial premises, such as bathrooms, utility rooms, or kitchens. Please read these instructions thoroughly before installation and use, and retain them for future reference.

Figura 1: Davant view of the Vortice Record Extractor Fan M10/4T 100mm with Timer. This image displays the fan's white casing and central circular grille.
2. Informació de seguretat
ADVERTIMENT: Per reduir el risc d'incendi, descàrrega elèctrica o lesions a les persones, observeu el següent:
- Installation must be carried out by a qualified electrician in accordance with all local and national wiring regulations.
- Always disconnect the power supply before performing any installation, maintenance, or cleaning.
- Aquest aparell no està pensat per ser utilitzat per persones (inclosos nens) amb capacitats físiques, sensorials o mentals reduïdes, o amb manca d'experiència i coneixements, tret que hagin rebut la supervisió o instruccions sobre l'ús de l'aparell per una persona responsable de la seva seguretat.
- Els nens han de ser supervisats per assegurar-se que no juguin amb l'aparell.
- No utilitzeu aquest ventilador amb cap dispositiu de control de velocitat d’estat sòlid.
- Ensure that the air discharge is not obstructed.
- The fan must not be installed in areas where the ambient temperature exceeds 40°C (104°F).
3. Contingut del paquet
Carefully unpack the product and check for any damage. If any components are missing or damaged, contact your retailer immediately.
- Vortice Record Extractor Fan M10/4T unit
- Manual d'instruccions
- Materials de muntatge (cargols, tacs de paret)
- Power cord (may not be included depending on regional regulations or specific model variant)
4. Especificacions
The following table outlines the key technical specifications for the Vortice Record Extractor Fan M10/4T 100mm with Timer.
| Característica | Especificació |
|---|---|
| Marca | Vòrtice |
| Nom del model | M10/4T (11630) |
| Disseny de ventilador elèctric | Ventilador d'escapament |
| Font d'alimentació | Cable elèctric |
| Voltage | 240 Volts |
| Wattage | 16 watts |
| Capacitat de cabal d'aire | 85 Cubic Meters Per Hour (approx. 50 CFM) |
| Nivell de soroll | 39 decibels |
| Longitud de la fulla | 100 mil·límetres |
| Pes de l'article | 0.43 quilograms (aproximadament 15.1 unces) |
| Dimensions del paquet | 18.4 L x 7.6 H x 13.0 W (centimeters) / 7.6 x 5.39 x 3.23 (inches) |
| Tipus d'instal·lació | Muntatge de paret |
| Tipus d'habitació | Bany |
| Característica especial | Funció de temporitzador |
| Mètode de control | Touch (likely referring to external switch) |
| Tipus d'acabat | Metàl·lic |
| Certificació | Aprovat CE |

Figura 2: Technical data and energy label for the Vortice Record Extractor Fan. Key data points include a maximum flow rate of 82 m³/h, total electrical power consumption of 14.3 W at maximum flow, and a sound power level (LWA) of 51 dB(A).
5. Instal·lació
Installation should only be performed by a qualified professional to ensure compliance with electrical safety standards and optimal performance.
5.1. Triar una ubicació
Select a suitable wall-mount location, typically in a bathroom or utility area, ensuring adequate space for the fan and ducting. Avoid locations directly above heat sources or where the fan might be exposed to direct water spray.

Figura 3: Example of a Vortice extractor fan installed on a wall in a room, demonstrating typical placement for ventilation.
5.2. Muntatge i cablejat
- Prepara l'obertura: Create an appropriate opening in the wall for the fan's ducting, typically 100mm in diameter. Refer to the dimensional drawing for precise measurements.
- Assegura el ventilador: Mount the fan unit securely to the wall using the provided mounting hardware. Ensure it is level and stable.
- Connexió elèctrica: Connect the fan to the main electrical supply. The M10/4T model includes a timer function, which requires specific wiring to a switched live and permanent live supply. Consult the wiring diagram provided with the product packaging or a qualified electrician for correct connection.
- Conductes: Connect appropriate ducting to the fan's outlet to direct extracted air outdoors. Ensure all connections are sealed to prevent air leakage.

Figura 4: Technical drawing illustrating the dimensions of the Vortice Extractor Fan, including overall width (A), height (B), depth (C), and duct diameter (E, F).
6. Funcionament
The Vortice Record Extractor Fan M10/4T is designed for simple operation, typically controlled via an external light switch or a dedicated fan switch.
6.1. Basic On/Off
When connected to a light switch, the fan will activate when the light is turned on. When connected to a dedicated fan switch, simply toggle the switch to turn the fan on or off.
6.2. Funció de temporitzador
The M10/4T model features an adjustable timer. After the fan is switched off (e.g., by turning off the light), the fan will continue to operate for a preset duration before automatically shutting down. This duration can typically be adjusted using a small potentiometer located within the fan unit (access usually requires removing the front cover and disconnecting power). Experiment with the timer setting to achieve the desired run-on time for effective ventilation.
7. Manteniment
Regular maintenance ensures optimal performance and longevity of your extractor fan. Always disconnect the power supply before any maintenance.
7.1. Neteja de l'exterior
Netegeu l'exterior del ventilador amb un drap suau iamp drap. No utilitzeu netejadors abrasius, dissolvents ni productes químics agressius, ja que poden danyar l'acabat.
7.2. Cleaning the Fan Blades
Periodically, dust and debris may accumulate on the fan blades, reducing efficiency. To clean:
- Desconnecteu l'alimentació: Ensure the fan's power supply is completely disconnected at the circuit breaker.
- Traieu la coberta: Traieu amb cura la reixeta frontal o la coberta del ventilador.
- Fulles netes: Gently clean the fan blades and surrounding areas with a soft brush or a vacuum cleaner with a brush attachment. Avoid bending the blades.
- Torneu a muntar: Once clean, reattach the cover securely.

Figura 5: Interna view of the Vortice Extractor Fan, showing the fan blades and motor housing, which may require periodic cleaning.
8. Solució De Problemes
If you encounter issues with your Vortice Extractor Fan, refer to the following common problems and solutions:
| Problema | Causa possible | Solució |
|---|---|---|
| El ventilador no s'encén | Sense font d'alimentació Cablejat defectuós Falla interna | Check circuit breaker and wall switch. Ensure correct wiring (consult electrician). If problem persists, contact support. |
| El ventilador fa excessivament sorollós | Muntatge solt Obstrucció a les pales del ventilador Problema motor | Ensure fan is securely mounted. Disconnect power and check for obstructions. If noise persists, contact support. |
| Extracció d'aire insuficient | Blocked ducting Pales de ventilador brutes Incorrect fan size for room | Check ducting for blockages. Clean fan blades as per maintenance section. Ensure fan is appropriately sized for the room volume. |
| El temporitzador no funciona correctament | Configuració incorrecta del temporitzador Problema de cablejat | Adjust the timer potentiometer. Verify timer wiring with an electrician. |
For issues not listed here or if solutions do not resolve the problem, please contact qualified technical support.
9. Garantia i Suport
9.1. Informació de la garantia
Please refer to the warranty card or documentation included with your purchase for specific warranty terms and conditions. Keep your proof of purchase for any warranty claims.
9.2. Atenció al client
For technical assistance, spare parts, or service, please contact your retailer or visit the official Vortice weblloc per obtenir informació de contacte d'assistència.