1. Introducció
This manual provides essential instructions for the safe and effective operation of the Amprobe AM-570 Industrial Digital Multimeter. The AM-570 is designed for professionals requiring accurate and reliable measurements in various electrical, HVAC/R, and industrial maintenance applications. Please read this manual thoroughly before using the device to ensure proper function and safety.
2. Informació de seguretat
To prevent electric shock or personal injury, and to avoid damage to the meter or the equipment under test, observe the following safety guidelines:
- Respecteu sempre els codis de seguretat locals i nacionals.
- El Amprobe AM-570 is rated for CAT IV 600 V and CAT III 1000 V. Do not exceed these ratings.
- Inspect test leads for damaged insulation or exposed metal before use. Replace damaged leads immediately.
- Assegureu-vos que l'interruptor de funció estigui en la posició correcta per a la mesura que s'està realitzant.
- No apliqueu més del volum nominaltage between terminals or between any terminal and ground.
- Tingueu precaució quan treballeu amb voltagper sobre de 30 V CA RMS, 42 V pic o 60 V CC. Aquests voltagsuposen un risc de xoc.
- Desconnecteu l'alimentació del circuit i descarregueu totes les emissions d'alt volumtage capacitors before performing resistance, continuity, diode, or capacitance tests.
- No feu funcionar el mesurador si sembla que està danyat o si no funciona correctament.
- Substituïu la bateria tan bon punt aparegui l'indicador de bateria baixa per garantir lectures precises.
- Quan feu servir el mesurador, utilitzeu només peces de recanvi especificades.
3. Contingut del paquet
Verify that all items listed below are present and undamaged:
- Amprobe AM-570 Industrial Digital Multimeter
- Test Leads (one pair, red and black)
- K-Type Thermocouple Probes (two)
- Maleta de transport
- Bateria de 9 V (preinstal·lada o inclosa per separat)
- Manual d'usuari (aquest document)

Imatge 3.1: El/La Amprobe AM-570 Digital Multimeter shown with its standard accessories, including test leads, two K-type thermocouple probes, and a soft carrying case.
4. Característiques del producte
El Amprobe AM-570 offers a comprehensive set of features for diverse electrical measurements:
- Mesures AC/DC Voltage fins a 1000 V
- Measures AC/DC Current
- Measures Resistance, Frequency, Capacitance, and Temperature
- Measures Duty Cycle
- True-RMS technology for accurate readings in non-linear loads
- Low Z mode to detect stray voltages and eliminate ghost readings
- Low Pass Filter for accurate voltage measurements on variable frequency drives (VFDs)
- Vol. Sense contactetage (NCV) detection for quick voltage presence checks
- Built-in flashlight for illumination in dimly lit areas
- Data Hold, MAX/MIN, and Peak Hold functions
- CAT IV 600 V / CAT III 1000 V safety rating

Imatge 4.1: El/La Amprobe AM-570 Digital Multimeter, showing its display, rotary dial, and function buttons. The display indicates a DC voltage reading of 119.4 V.

Imatge 4.2: Un angle view de la Amprobe AM-570 Digital Multimeter, highlighting the clear digital display, which currently shows a frequency reading of 0.000 kHz.
5. Configuració
5.1 Instal·lació de la bateria
- Assegureu-vos que el comptador estigui apagat.
- Localitzeu el compartiment de la bateria a la part posterior del mesurador.
- Feu servir un tornavís per afluixar el cargol que fixa la tapa de la bateria.
- Traieu la tapa de la bateria.
- Introduïu una pila nova de 9 V, respectant la polaritat correcta.
- Substituïu la tapa de la bateria i fixeu-la amb el cargol.
5.2 Connexió dels cables de prova
Always connect the black test lead to the COM (common) terminal. Connect the red test lead to the appropriate input terminal based on the measurement function:
- VΩHz: For voltage, resistance, frequency, capacitance, and diode/continuity measurements.
- mAµA: For milliampere i microampmesures actuals.
- 10A: For high current (up to 10A) measurements.

Imatge 5.1: El/La Amprobe AM-570 Digital Multimeter shown with its integrated kickstand extended, allowing for hands-free viewdurant el funcionament.
6. Instruccions de funcionament
The AM-570 features a rotary dial for selecting primary measurement functions and push buttons for secondary functions and settings.
6.1 Selecció de la funció
Turn the rotary dial to the desired measurement function. Use the SELECCIONA button to toggle between primary and secondary functions within a single dial position (e.g., AC/DC voltage, resistència/continuïtat/díode).
6.2 Funcions de mesura
- Voltage (V~ / V--): Select the V~ (AC) or V-- (DC) position. Connect test leads in parallel with the circuit.
- Current (10A / mAµA): Select the 10A or mAµA position. Connect the meter in series with the circuit. Ensure correct terminal connection.
- Resistència (Ω): Select the Ω position. Ensure power is off and capacitors are discharged. Connect test leads across the component.
- Continuity ())): Select the Ω position and press SELECCIONA until the continuity symbol appears. A continuous beep indicates continuity.
- Diode Test (→|): Select the Ω position and press SELECCIONA until the diode symbol appears. Connect leads across the diode.
- Capacitat (F): Select the F position. Ensure power is off and capacitors are discharged. Connect leads across the capacitor.
- Frequency (Hz) / Duty Cycle (%): Select the Hz% position. Connect leads to the signal source. Press SELECCIONA to toggle between frequency and duty cycle.
- Temperatura (°C/°F): Select the TEMP °C/°F position. Insert K-type thermocouple probes into the T1 and T2 inputs. Press SELECCIONA to toggle between Celsius and Fahrenheit.
- Vol. Sense contactetage (NCV): Select the NCV position. Hold the top of the meter near a live conductor. The NCV indicator and audible alarm will activate if voltages detecta e.
- Low Z Mode: Select the LoZ V~ position for AC voltage measurements with low impedance. This helps to eliminate ghost voltages.
- Filtre de pas baix: Activated automatically in certain AC voltage modes, this filter allows for accurate measurements on variable frequency drives.
6.3 Funcions especials
- GAMMA: Manually select the measurement range instead of auto-ranging.
- REL (Relative Mode): Measures the difference between a stored reference value and the current reading.
- MAX/MIN: Records the maximum and minimum values over a measurement period.
- MANTENIM: Freezes the current display reading.
- PEAK (1ms): Captures fast transient peaks (positive and negative) with a 1ms response time.

Image 6.1: An electrician utilizing the Amprobe AM-570 Digital Multimeter to perform voltage measurements within an industrial electrical panel, demonstrating practical application.
7. Manteniment
7.1 Neteja
Netegeu el comptador amb anuncisamp drap i detergent suau. No utilitzeu abrasius ni dissolvents. Assegureu-vos que el mesurador estigui sec abans d'utilitzar-lo.
7.2 Substitució de la bateria
Refer to Section 5.1 for detailed instructions on replacing the 9V battery. Replace the battery promptly when the low battery indicator appears on the display.
7.3 Canvi de fusibles
If the current measurement functions cease to operate, the internal fuses may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the full service manual for fuse specifications and replacement procedures. Always use fuses with the specified voltage i qualificacions actuals.
7.4 Emmagatzematge
When not in use for extended periods, remove the battery to prevent leakage. Store the meter in a cool, dry environment, preferably in its carrying case.
8. Solució De Problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El comptador no s'encén | Bateria morta o instal·lada incorrectament | Check battery polarity; replace battery (see Section 5.1). |
| No reading or "OL" (Overload) displayed | Incorrect function selected; open circuit; measurement range exceeded | Verify function switch position; check circuit continuity; select a higher range or auto-range. |
| Lectures inexactes | Low battery; dirty test leads/terminals; external interference | Replace battery; clean leads and terminals; move away from strong electromagnetic fields. |
| La mesura de corrent no funciona | Fusible cremat | Replace fuse (see Section 7.3). |
| NCV function inconsistent | Environmental factors; sensor position | Ensure direct proximity to live conductor; NCV is for indication only, use test leads for precise voltage verificació. |
9. Especificacions
| Paràmetre | Detall |
|---|---|
| Model | AM-570 |
| Fabricant | Amptúnica |
| Capacitats de mesura | Volum AC / DCtage, AC/DC Current, Resistance, Frequency, Capacitance, Temperature, Duty Cycle |
| Classificació de seguretat | CAT IV 600 V / CAT III 1000 V |
| RMS veritable | Sí |
| Low Z Mode | Sí |
| Filtre de pas baix | Sí |
| Font d'alimentació | Bateria de 9 V |
| Dimensions del producte | 4 x 10 x 2 polzades (10.16 x 25.4 x 5.08 cm) |
| Pes de l'article | 13.05 unces (370 grams) |
| Color | Black with Red overmolding |
10. Garantia i Suport
Amprobe products are designed for reliability and performance. This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Amptúnica weblloc.
For technical support, service, or replacement parts, please contact Amprobe customer service. Contact information can typically be found on the Amptúnica weblloc o a l'embalatge del producte.