1. Introducció
This manual provides essential information for the proper installation, operation, and maintenance of the Johnson Controls FA-VAV111-1 HVAC Controller Facilitator. This device is a critical component in HVAC control systems, designed to manage and facilitate various functions within a building's heating, ventilation, and air conditioning infrastructure. Adherence to these instructions is crucial for optimal performance and safety.

Figura 1: Frontal view of the Johnson Controls FA-VAV111-1 HVAC Controller Facilitator.
2. Informació de seguretat
Always observe standard safety precautions when working with electrical equipment. Installation and servicing should only be performed by qualified personnel. Disconnect all power to the unit and associated equipment before performing any installation, maintenance, or troubleshooting procedures.
- Ensure power supply matches the device's specifications (24 VAC, Class 2).
- Eviteu el contacte amb components elèctrics actius.
- Proper grounding procedures must be followed.
- Protegiu el dispositiu de la humitat i les temperatures extremes.
3. Producte acabatview
The FA-VAV111-1 is a 2 Amp, 24 VAC, Class 2 Controller Facilitator designed for integration into HVAC control systems. It functions as an HVAC Control System Board, providing necessary interfaces and control logic for various system components. Key features include:
- 2 Amp qualificació actual.
- 24 VAC power input, Class 2.
- Binary Output (BIN OUT): 24 VAC, Class 2, 0.5A Pilot Duty.
- Analog Output (ANA OUT): 0-10 VDC, Class 2, 0.01A.
4. Configuració i instal·lació
Careful installation is essential for the reliable operation of the FA-VAV111-1 controller. Refer to the detailed wiring diagrams and system schematics provided with your specific HVAC system for precise connection points.
4.1 Muntatge
Mount the controller in a secure, dry location, free from excessive vibration and within its specified operating temperature range. Ensure adequate ventilation around the unit to prevent overheating. Use appropriate fasteners for mounting to a stable surface.
4.2 Connexions elèctriques
All wiring must comply with local and national electrical codes. Use appropriate wire gauges for all connections.
- Entrada d'alimentació: Connect the 24 VAC, Class 2 power supply to the designated power input terminals. The unit requires a 2 Amp subministrament.
- Binary Outputs (BIN OUT): Connect control devices requiring 24 VAC, 0.5A pilot duty to the binary output terminals.
- Analog Outputs (ANA OUT): Connect devices requiring 0-10 VDC, 0.01A analog signals to the analog output terminals.
- Entrades analògiques: Connect sensors or other devices providing analog input signals to the analog input terminals. Refer to the device label for specific input types (e.g., TEMP, 2VDC, 10VDC).
- Entrades binàries: Connect switches or other devices providing binary input signals to the binary input terminals.

Figura 2: lateral view illustrating the various connection terminals for inputs and outputs.

Figura 3: A baix view detailing additional connection points and component layout.

Figure 4: Close-up of the product label, showing model number, power ratings, and output specifications.
5. Instruccions de funcionament
The Johnson Controls FA-VAV111-1 operates as a facilitator within a larger HVAC control system. Its specific operational parameters and control logic are determined by the programming of the overall system. Once properly installed and powered, the unit will execute the programmed control sequences based on its inputs and generate the corresponding outputs.
- Ensure all connected devices are functioning correctly.
- Monitor system performance through the main HVAC control interface.
- The 0-10 VDC analog output provides proportional control signals to compatible devices.
- The 24 VAC binary outputs are used for on/off control of pilot duty loads.
6. Manteniment
The FA-VAV111-1 controller is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and prevent system failures.
- Inspecció visual: Periodically inspect the unit for any signs of physical damage, loose connections, or dust accumulation.
- Neteja: If necessary, gently clean the exterior of the unit with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure power is disconnected before cleaning.
- Integritat de la connexió: Verify that all wiring connections remain secure and free from corrosion.
- Condicions ambientals: Assegureu-vos que l'entorn operatiu es mantingui dins dels límits de temperatura i humitat especificats.
7. Solució De Problemes
If the FA-VAV111-1 controller or the associated HVAC system is not functioning as expected, consider the following troubleshooting steps:
- Sense energia: Check the 24 VAC power supply. Ensure the circuit breaker or fuse is not tripped. Verify all power connections are secure.
- Incorrect Output: Verify the input signals to the controller are correct. Check the wiring to the output devices. Ensure the output device itself is functional.
- Mal funcionament del sistema: If the entire HVAC system is not responding, consult the overall system's diagnostic tools and documentation. The FA-VAV111-1 is a component; issues may originate elsewhere in the control network.
- Connexions soltes: Inspect all terminal connections for tightness and proper seating.
- Factors ambientals: Ensure the unit is not exposed to extreme heat, cold, or moisture.
If problems persist after performing these checks, contact qualified service personnel or Johnson Controls technical support.
8. Especificacions
| Paràmetre | Valor |
|---|---|
| Número de model | FA-VAV111-1 |
| Entrada de potència | 24 VAC, Class 2, 2 Amp |
| Binary Output (BIN OUT) | 24 VAC, Class 2, 0.5A Pilot Duty |
| Analog Output (ANA OUT) | 0-10 VDC, Class 2, 0.01A |
| Dimensions del producte | 6.5 x 2.14 x 6.5 polzades |
| Pes de l'article | 1.23 pounds (approximately 1.2 pounds) |
| Fabricant | CONTROLS JOHNSON |
| Piles necessàries | No |
9. Garantia i Suport
For information regarding product warranty, technical support, or service, please contact Johnson Controls directly or refer to their official website. Keep your purchase receipt and product model number (FA-VAV111-1) readily available when seeking support.





