Johnson Controls V-9012-1

Manual d'instruccions del relé de la vàlvula solenoide Johnson Controls V-9012-1

Model: V-9012-1

1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the Johnson Controls V-9012-1 E/P Solenoid Relay. This device is designed to convert an electrical signal into a pneumatic output, controlling air pressure based on a 12 VDC input. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the product.

2. Informació de seguretat

Adherence to safety precautions is crucial for preventing injury and damage to the equipment. Always follow local codes and regulations.

  • Personal qualificat: Installation and servicing must be performed by qualified and experienced personnel only.
  • Seguretat elèctrica: Disconnect all power to the device and associated equipment before performing any wiring or maintenance. Ensure proper grounding.
  • Pneumatic Safety: Depressurize all pneumatic lines before making or breaking connections. Wear appropriate personal protective equipment.
  • Condicions ambientals: Do not expose the device to conditions outside its specified operating range (temperature, humidity, pressure).

3. Producte acabatview

The Johnson Controls V-9012-1 is an Electro-Pneumatic (E/P) Solenoid Relay that converts a 12 VDC electrical input into a pneumatic control signal. It is commonly used in industrial applications to manage air pressure for actuators or other pneumatic devices.

3.1. Característiques clau

  • 12 VDC Input for electrical control.
  • Solenoid Valve functionality for precise pneumatic regulation.
  • Relay operation for switching pneumatic states.
  • Maximum input current of 50 mA.

3.2. Components and Labeling

Refer to the image below for a visual representation of the V-9012-1 Solenoid Valve Relay and its key labeled components.

Johnson Controls V-9012-1 E/P Solenoid Relay with labels

Figure 1: Johnson Controls V-9012-1 E/P Solenoid Relay

The image displays the Johnson Controls V-9012-1 E/P Solenoid Relay. Key labels visible on the device include:

  • V-9012-1 E/P SOLENOID RELAY: Identifies the model and type of device.
  • PAT 4,770,200 and PAT 4,804,009: Patent numbers associated with the product.
  • BO TERM. 1 (RED): Indicates the first electrical terminal, typically for the positive 12 VDC input.
  • 12 V.D.C. INPUT (50 mA. MAX.): Specifies the required input voltage i corrent màxima.
  • BO TERM. 2 (BLK) RESISTOR: Indicates the second electrical terminal, typically for the negative connection, and notes the presence of a resistor.
  • SUBMINISTRAMENT: The inlet port for the pneumatic supply pressure.
  • ACTUATOR: The outlet port for the controlled pneumatic pressure to the actuator.
  • +12 V.D.C. PRESS.: Indicates that a +12 VDC input results in a 'PRESS' (pressure) state.
  • 0 V.D.C. HOLD: Indicates that 0 VDC input results in a 'HOLD' state.
  • -12 V.D.C. EXHAUST: Indicates that a -12 VDC input results in an 'EXHAUST' state.

4. Configuració i instal·lació

Proper installation is critical for the correct functioning of the V-9012-1 Solenoid Relay.

4.1. Comprovacions prèvies a la instal·lació

  • Verify that the power supply matches the device's requirements (12 VDC).
  • Inspect the device for any visible damage from shipping.
  • Ensure all necessary tools and fittings are available.

4.2. Muntatge

Mount the solenoid relay securely in a location that is free from excessive vibration, moisture, and extreme temperatures. Ensure adequate space for wiring and pneumatic connections.

4.3. Instruccions de cablejat

Seguiu aquests passos per a les connexions elèctriques:

  1. Ensure the power source is completely disconnected.
  2. Connect the positive (+) 12 VDC power supply wire to BO TERM. 1 (RED).
  3. Connect the negative (-) 12 VDC power supply wire to BO TERM. 2 (BLK). Note that this terminal includes a resistor.
  4. Comproveu que totes les connexions estiguin segures i aïllades correctament.

4.4. Pneumatic Connections

Follow these steps for pneumatic connections:

  1. Connect the main pneumatic supply line to the port labeled SUBMINISTRACIÓ. Ensure the supply pressure is within the device's specified operating range.
  2. Connect the line leading to the pneumatic actuator or controlled device to the port labeled ACTUADOR.
  3. Check all pneumatic connections for leaks after pressurizing the system.

5. Funcionament

The V-9012-1 Solenoid Relay operates based on the applied electrical input voltage, controlling the pneumatic output to the actuator.

  • +12 VDC Input: When a positive 12 VDC is applied to the input terminals, the relay will enter a 'PRESS' state, allowing supply pressure to flow to the actuator.
  • 0 VDC Input: When 0 VDC (no voltage) is applied, the relay will enter a 'HOLD' state, maintaining the current pneumatic output.
  • -12 VDC Input: When a negative 12 VDC is applied, the relay will enter an 'EXHAUST' state, releasing pressure from the actuator.

Ensure that the control system provides the correct voltage signals for the desired pneumatic response.

6. Manteniment

The Johnson Controls V-9012-1 Solenoid Relay is designed for reliable operation with minimal maintenance. However, periodic checks can help ensure longevity and optimal performance.

  • Inspecció de rutina: Periodically inspect the device for any signs of wear, corrosion, or damage to the housing, wiring, and pneumatic connections.
  • Neteja: Keep the exterior of the device clean and free from dust and debris. Do not use harsh chemicals or abrasive cleaners.
  • Integritat de la connexió: Verify that all electrical and pneumatic connections remain tight and secure.
  • Servei professional: For internal issues or complex repairs, contact a qualified service technician or Johnson Controls support. Do not attempt to disassemble the unit.

7. Solució De Problemes

This section provides solutions to common issues that may arise during the operation of the V-9012-1 Solenoid Relay.

ProblemaCausa possibleSolució
Device does not respond to electrical input.No power, incorrect voltage, loose wiring, internal fault.Check 12 VDC power supply. Verify wiring connections to Terminals 1 and 2. Ensure correct polarity. If problem persists, contact support.
Pneumatic output is incorrect or inconsistent.Insufficient supply pressure, clogged lines, leaks in pneumatic connections, internal valve issue.Check pneumatic supply pressure. Inspect lines for obstructions or leaks. Ensure correct electrical input for desired pneumatic state.
El dispositiu s'està sobreescalfant.Excessive current, improper ventilation, continuous operation beyond duty cycle.Verify input current does not exceed 50 mA. Ensure adequate airflow around the device. Review application for duty cycle requirements.

8. Especificacions

Technical specifications for the Johnson Controls V-9012-1 E/P Solenoid Relay:

ParàmetreValor
Número de modelV-9012-1
FuncióE/P Solenoid Relay
Entrada Voltage12 VDC
Corrent d'entrada màxim50 mA
Pneumatic StatesPress (+12 VDC), Hold (0 VDC), Exhaust (-12 VDC)
FabricantCONTROLS JOHNSON
Pes de l'article6.4 unces
Data de primera disponibilitat5 de juliol de 2012

9. Garantia i Suport

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly through their official website or customer service channels. Keep your purchase receipt and product model number readily available when seeking support.

Documents relacionats - V-9012-1

Preview Vàlvules de trim de gàbia de bronze de Johnson Controls: Guia de productes de 3/4 a 2 polzades
Guia tècnica completa per a les vàlvules de gàbia de bronze Johnson Controls (de 3/4 a 2 polzades), que detalla les característiques, les opcions d'actuadors pneumàtics i elèctrics, les especificacions, el funcionament, la instal·lació i les peces de reparació per a aplicacions de climatització.
Preview Johnson Controls EP-8000 Series Electro-Pneumatic Transducers: Technical Specifications, Installation, and Operation
Detailed technical bulletin for Johnson Controls EP-8000 Series Electro-Pneumatic Transducers. Covers product overview, operation, dimensions, installation, wiring, calibration, and technical specifications for industrial control applications.
Preview Guia d'instal·lació de les vàlvules de control de bronze de la sèrie VG7000
Instruccions d'instal·lació completes i especificacions tècniques per a les vàlvules de control de bronze de la sèrie VG7000 de Johnson Controls, dissenyades per regular l'aigua i el vapor en sistemes de climatització. Inclou les dimensions de la vàlvula, els materials i els paràmetres de funcionament.
Preview Catàleg de peces de reparació de vàlvules Johnson Controls
Catàleg complet que detalla les peces de recanvi, incloent-hi diafragmes, kits de molles, kits d'empastament, kits de reacondicionament i altres components per a una àmplia gamma de vàlvules pneumàtiques i elèctriques Johnson Controls.
Preview Guia d'instal·lació del dispositiu de corrent de nucli dividit de la sèrie CSD de Johnson Controls
Guia tècnica i d'instal·lació per als dispositius de corrent de nucli dividit de la sèrie CSD de Johnson Controls (CSD-CF0J1-1, CSD-CA1G1-1) amb relé. Cobreix aplicacions, cablejat, calibratge, resolució de problemes i especificacions per a la monitorització del corrent industrial.
Preview Guia d'instal·lació de la vàlvula de control compacta de globus (axial) VP1000
Guia d'instal·lació de la vàlvula de control compacta axial (global) Johnson Controls VP1000, que cobreix mides d'1/2 polzada a 1 1/4 polzada (DN15-DN32). Proporciona especificacions tècniques, instruccions de muntatge i informació de manteniment.