Johnson Controls MR4PMUHV-12C

Manual d'usuari del control de descongelació Johnson Controls MR4PMUHV-12C

1. Introducció

The Johnson Controls MR4PMUHV-12C Defrost Control is engineered for use in refrigeration and freezer units, supporting both hot gas and electric heat defrost methods. This control unit offers flexible defrost termination options, allowing selection between time-based or temperature-based methods. It integrates essential control functions including compressor management, defrost cycle management, fan operation control, and alarm management, providing a comprehensive solution for HVAC systems.

Johnson Controls MR4PMUHV-12C Defrost Control unit with two coiled temperature sensors

Figura 1: Johnson Controls MR4PMUHV-12C Defrost Control unit and included temperature sensors. The central gray unit features a digital display and control buttons, while two coiled gray cables with metallic tips represent the temperature sensors.

2. Què hi ha a la caixa

3. Característiques clau

4. Configuració i instal·lació

Proper installation is crucial for the safe and efficient operation of the defrost control. Always ensure power is disconnected before beginning any installation or wiring procedures.

  1. La seguretat primer: Disconnect all power to the refrigeration or freezer unit before proceeding. Follow all local electrical codes and safety guidelines.
  2. Muntatge: Select a suitable location for mounting the control unit and, if applicable, the separate relay pack. Ensure adequate ventilation and protection from moisture. The flexible design allows for combined or separate mounting.
  3. Connexions de cablejat:
    • Connect the 24VAC power supply to the designated terminals on the control unit.
    • Wire the compressor, fans, and defrost heaters to the heavy-duty relay terminals as per the wiring diagram provided with the product.
    • Connect any external alarm systems to the dedicated alarm terminals.
  4. Instal·lació del sensor: Install the temperature sensors in the appropriate locations within the evaporator or process area as required for accurate temperature monitoring. Ensure sensor cables are routed safely and securely.
  5. Engegada inicial: Once all connections are secure and verified, restore power to the unit. The control unit display should illuminate.

5. Funcionament

After successful installation, the MR4PMUHV-12C is ready for configuration and operation.

  1. Visualització finalitzadaview: Upon power-up, the digital display will show the current temperature. Pressing the designated button (refer to product-specific labeling) allows toggling between evaporator and process temperature readings.
  2. Setting Defrost Parameters: Access the control unit's menu (typically via dedicated buttons) to configure defrost settings. This includes:
    • Interval de descongelació: Set the frequency at which defrost cycles occur.
    • Defrost Duration: Specify the maximum time for a defrost cycle.
    • Defrost Termination Method: Choose between time-based termination (defrost ends after a set duration) or temperature-based termination (defrost ends when a specific temperature is reached).
    • Fan Delay: Configure any fan delay settings post-defrost.
  3. Configuració d'alarma: Configure temperature thresholds for alarms to ensure optimal operating conditions and prompt notification of deviations.
  4. Seguiment: Regularly check the display for current temperatures and system status.

6. Manteniment

Routine maintenance helps ensure the longevity and reliable performance of your defrost control unit.

7. Solució De Problemes

Aquesta secció ofereix orientació per a problemes comuns. Per a problemes complexos, poseu-vos en contacte amb personal de servei qualificat.

8. Especificacions

Número de modelMR4PMUHV-12C
Dimensions del producte10.5 x 5.5 x 6.5 polzades
Pes de l'article3.17 Pounds (3.2 Pounds listed elsewhere)
MarcaJohnson Controls
MaterialPlàstic
Temperatura de funcionament32 graus Fahrenheit (0 °C)
FabricantJohnson Controls Inc

9. Garantia i Suport

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly or refer to the official documentation included with your purchase. Keep your proof of purchase for warranty claims.

Johnson Controls Contact Information: Please visit the official Johnson Controls weblloc web per obtenir les dades de contacte i els recursos d'assistència més actualitzats.

Documents relacionats - MR4PMUHV-12C

Preview Instruccions d'instal·lació dels controls electrònics de temperatura Johnson Controls sèrie A421 amb descongelació fora de cicle
Guia d'instal·lació completa per als controls electrònics de temperatura Johnson Controls PENN sèrie A421, amb funció de descongelació fora de cicle. Cobreix el producte més deview, aplicacions, dimensions, muntatge, cablejat, configuració, ajustos, resolució de problemes i especificacions tècniques.
Preview Controls electrònics de temperatura de la sèrie A419 amb pantalla i carcasses estanques NEMA 1 o NEMA 4X
Aquest butlletí tècnic de Johnson Controls detalla els controls electrònics de temperatura de la sèrie A419, dissenyats per a aparells individuals.tagAplicacions de refrigeració i climatització. Cobreix les característiques, els avantatges, les opcions de carcassa NEMA 1 i NEMA 4X, el funcionament, el cablejat, els ajustos, la resolució de problemes, els codis d'error, la informació de comandes i les especificacions tècniques.
Preview Johnson Controls A19 Series Remote Bulb Control - Temperature Sensors
Detailed specifications and selection guide for Johnson Controls A19 Series remote bulb temperature controls, used in HVAC, heating, ventilating, and refrigeration applications. Includes model numbers, electrical ratings, and features.
Preview Pàgina del catàleg de control remot de bombetes PENN sèrie A19 | Johnson Controls
Pàgina del catàleg dels comandaments a distància de la sèrie PENN A19, amb llums individuals.tagControls de temperatura electrònics amb elements sensors plens de líquid. Inclou gràfics de selecció, especificacions tècniques, peces de recanvi i informació de contacte.
Preview Manual d'informació de l'usuari del termòstat de pantalla tàctil Hx 3
Aquest manual d'informació per a l'usuari proporciona instruccions detallades i orientació per al termòstat de pantalla tàctil Johnson Controls Hx 3 (Model: S1-THXU430W), que cobreix la instal·lació, les funcions, el funcionament, la connectivitat de l'aplicació i la configuració.
Preview G600 Series Replacement Intermittent Pilot Ignition Controls Installation Instructions
Comprehensive installation, mounting, wiring, setup, operation, and troubleshooting guide for the Johnson Controls G600 Series Replacement Intermittent Pilot Ignition Controls.