Johnson Controls LP-XP91D04-000C

JOHNSON CONTROLS LP-XP91D04-000C Expansion Module

Model: LP-XP91D04-000C

Marca: Johnson Controls

Introducció

This manual provides essential information for the proper installation, operation, and maintenance of the JOHNSON CONTROLS LP-XP91D04-000C Expansion Module. This module is designed as a Facility Explorer Extension, providing 4 Digital Inputs and 4 Digital Outputs for integration into building automation and control systems.

It is crucial to read and understand all instructions before attempting to install or operate this device. Retain this manual for future reference.

Informació de seguretat

ADVERTIMENT: This device should only be installed and serviced by qualified personnel. Failure to follow these instructions could result in personal injury, property damage, or damage to the equipment.

  • Always disconnect power before installing or servicing the module.
  • Assegureu-vos que tot el cablejat compleixi amb els codis elèctrics locals i nacionals.
  • Do not operate the module outside its specified environmental limits.
  • Protegiu el mòdul de la humitat, la pols i les temperatures extremes.

Configuració i instal·lació

The LP-XP91D04-000C module is designed for integration into a larger Facility Explorer system. Proper installation is critical for reliable operation.

For detailed installation instructions, refer to the official Johnson Controls Installation Guide XT/XP-91DOx, Part Number 24-85594-272, Issue Date 2605 or later. This guide provides comprehensive information on mounting, wiring, and system integration.

Físic acabatview

Davant view of the Johnson Controls LP-XP91D04-000C Expansion Module showing digital input and output indicators.

Figura 1: Davant view of the LP-XP91D04-000C Expansion Module. This image displays the module's front panel, including the "FACILITY EXPLORER" branding, "JOHNSON CONTROLS" logo, and indicators for Digital Inputs (DI1-DI4) and Digital Outputs (DO5-DO8). The model number "XP91D04" is also visible, along with the part number "LP-XP91D04-000C" and CE marking on a label.

posterior view of the Johnson Controls LP-XP91D04-000C Expansion Module showing regulatory labels.

Figura 2: posterior view of the LP-XP91D04-000C Expansion Module. This image shows the back of the module, featuring regulatory labels such as "ENERGY MANAGEMENT EQUIPMENT SUBASSEMBLY" and UL listing (E226431, LISTED 2HD3). Text indicating "For installation information see Installation Guide XT/XP-91DOx P/No 24-85594-272 Issue Date 2605 or later" is also clearly visible.

A baix view of the Johnson Controls LP-XP91D04-000C Expansion Module showing mounting clips.

Figura 3: A baix view of the LP-XP91D04-000C Expansion Module. This image displays the underside of the module, highlighting the mounting clips and overall casing design, which facilitates secure installation within a control panel or enclosure.

Connexions de cablejat

The module features terminal blocks for connecting digital inputs and outputs. Ensure proper polarity and secure connections for all wiring.

  • Digital Inputs (DI1-DI4): These terminals are used to receive digital signals from external devices, such as sensors or switches.
  • Digital Outputs (DO5-DO8): These terminals provide digital control signals to external devices, such as relays or indicators.
  • Refer to the specific wiring diagrams in the Installation Guide for detailed connection procedures.

Principis de funcionament

The LP-XP91D04-000C module extends the capabilities of a Facility Explorer system by providing additional digital I/O points. Once properly installed and configured within the system, the module's digital inputs can be monitored, and its digital outputs can be controlled via the Facility Explorer software interface.

  • Entrades digitals: These inputs typically detect the presence or absence of a voltage, representing states like ON/OFF, open/closed, or occupied/unoccupied.
  • Sortides digitals: These outputs can be used to switch external devices on or off, activate alarms, or control simple binary functions.

Specific operational parameters and programming details are managed through the Facility Explorer system software, which is beyond the scope of this hardware manual.

Manteniment

The LP-XP91D04-000C Expansion Module is designed for reliable, long-term operation with minimal maintenance. However, periodic checks can help ensure optimal performance.

  • Inspecció visual: Inspeccioneu periòdicament el mòdul i el seu cablejat per detectar qualsevol signe de danys, connexions soltes o corrosió.
  • Neteja: Si cal, netegeu suaument l'exterior del mòdul amb un drap suau i sec. No utilitzeu productes de neteja abrasius ni dissolvents.
  • Condicions ambientals: Assegureu-vos que l'entorn operatiu es mantingui dins dels rangs de temperatura i humitat especificats per evitar fallades prematures.

No user-serviceable parts are inside the module. Do not attempt to open the casing.

Resolució de problemes

If the LP-XP91D04-000C module is not functioning as expected, consider the following common troubleshooting steps:

ProblemaCausa possibleSolució
El mòdul no responNo power; Loose communication wiring; Incorrect system configuration.Verify power supply; Check all communication cables for secure connections; Consult Facility Explorer system documentation for configuration.
Digital Input not reading correctlyFaulty sensor/switch; Incorrect wiring to input terminal; Input not configured correctly in software.Test external sensor/switch; Check input wiring for continuity and correct polarity; Verify input configuration in Facility Explorer software.
Digital Output not activatingFaulty external device; Incorrect wiring from output terminal; Output not commanded correctly in software.Test external device (e.g., relay); Check output wiring for continuity and correct polarity; Verify output command in Facility Explorer software.

If problems persist after attempting these steps, contact Johnson Controls technical support or a qualified service technician.

Especificacions

AtributValor
Número de modelLP-XP91D04-000C
DescripcióExpansion Module, Facility Explorer Extension, 4 Digital Inputs, 4 Digital Outputs
FabricantCONTROLS JOHNSON
Pes de l'article5.92 unces
ASINB008HQ73VS
Data de primera disponibilitat21 de febrer de 2025

Garantia i Suport

For information regarding product warranty, please refer to the official Johnson Controls warranty statement provided with your purchase or available on the Johnson Controls website. Warranty terms may vary by region and product type.

For technical support, service, or additional documentation, please contact Johnson Controls directly through their official website or customer service channels. Provide your product model number (LP-XP91D04-000C) and any relevant system details when seeking support.

Johnson Controls Official Weblloc: www.johnsoncontrols.com

Documents relacionats - LP-XP91D04-000C

Preview Butlletí tècnic del controlador Johnson Controls FX15: instal·lació, funcionament i especificacions
Aquest butlletí tècnic proporciona detalls complets sobre el controlador Johnson Controls FX15, un controlador de camp d'alt rendiment per a aplicacions comercials de climatització i refrigeració (HVACR). Cobreix la instal·lació, els conceptes clau, les configuracions d'entrada/sortida, els procediments operatius, les especificacions tècniques i la guia per a la resolució de problemes. Conegui la seva programabilitat, les capacitats d'expansió amb mòduls XT/XP i la integració amb sistemes d'automatització d'edificis mitjançant els protocols N2 Open i LONWORKS.
Preview FX CommPro N2 User's Guide: Software for Facility Explorer Controllers
Explore the FX CommPro N2 User's Guide from Johnson Controls. Learn to download software, commission, and manage Facility Explorer controllers for building automation.
Preview Johnson Controls LP-3500 Lighting Control Panel User's Guide
Comprehensive guide for the Johnson Controls LP-3500 Lighting Control Panel, detailing hardware features, software configuration with LP-CT 4.0, and operational procedures for automated lighting systems.
Preview Johnson Controls FX07 Field Controller Technical Bulletin and Specification Guide
Explore the capabilities of the Johnson Controls FX07 Field Controller with this comprehensive technical bulletin. Learn about its HVACR applications, installation, operation, communication protocols (N2 Open, LONWORKS, BACnet), and technical specifications for building automation systems.
Preview Instruccions d'instal·lació i actualització de SCT
Guia completa per instal·lar i actualitzar el programari System Configuration Tool (SCT) en ordinadors d'escriptori o de classe servidor. Cobreix els requisits previs, els requisits del sistema operatiu, la configuració de SQL Server i els procediments detallats per a un procés d'instal·lació sense problemes.
Preview Guia d'inici ràpid del mòdul d'actualització i expansió de PowerG Qolsys amb cable a sense fil
Aquesta guia proporciona instruccions pas a pas per actualitzar el firmware i configurar el mòdul d'actualització i expansió PowerG Qolsys Wired to Wireless (W2W) amb el panell de seguretat IQ2+, inclosa la configuració de les regles PGM i les opcions del sistema.