Vortice 11638

Extractor centrífug Vortice 11638 Micro 80 per a conductes - Manual d'usuari

Model: 11638 | Brand: Vortice

1. Producte acabatview

The Vortice Micro 80 Centrifugal Extractor Fan, Model 11638, is a high-performance ventilation unit designed for efficient air extraction in ducted systems. Its compact design and robust construction make it suitable for various applications, particularly in bathrooms and utility rooms. This fan is engineered for reliability and quiet operation, ensuring effective air circulation.

Vortice Micro 80 Centrifugal Extractor Fan, angled view

Figura 1.1: Angle view of the Vortice Micro 80 Centrifugal Extractor Fan, showcasing its white ABS plastic casing and front grille design.

Vortice Micro 80 Centrifugal Extractor Fan, front view

Figura 1.2: Frontal view of the Vortice Micro 80 fan, highlighting the nine circular vents and the 'Vortice' logo.

2. Informació de seguretat

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Configuració i instal·lació

The Vortice Micro 80 fan is designed for wall mounting and connection to ductwork. Ensure the mounting surface is stable and capable of supporting the unit's weight.

3.1 Contingut del paquet

3.2 Muntatge de la unitat

  1. Choose a suitable wall location, ensuring adequate space for duct connection and maintenance.
  2. Mark the drilling points on the wall using the fan's mounting holes as a template.
  3. Perfora forats i insereix els tacs de paret adequats.
  4. Secure the fan to the wall using the provided screws.

3.3 Connexió elèctrica

The fan operates on 220-240V AC. It features a 2-speed induction motor. Wiring should be done by a qualified professional.

  1. Ensure the main power supply is OFF before making any connections.
  2. Open the wiring compartment on the fan.
  3. Connect the live (Phase) and neutral wires to the designated terminals. The fan supports two speeds, which can be controlled via an external regulator (not included). Refer to the wiring diagram for specific connections for each speed.
  4. Connect the ground wire to the grounding terminal.
  5. Close the wiring compartment securely.

3.4 Duct Connection

The fan is designed for 80 mm diameter ducts.

Interna view of Vortice Micro 80 fan showing impeller and duct connection point

Figura 3.1: Intern view of the fan, illustrating the centrifugal impeller and the circular opening for duct connection. Note the backdraft dampeh.

  1. Connect the appropriate ducting to the fan's outlet. Ensure a tight and secure fit to prevent air leaks.
  2. The fan includes a non-return valve (backdraft damper) to prevent air from flowing back into the room when the fan is off. Ensure it operates freely.
Technical drawing with dimensions of Vortice Micro 80 fan

Figure 3.2: Technical drawing providing detailed dimensions (in mm) of the Vortice Micro 80 fan from various perspectives, useful for installation planning.

4. Instruccions de funcionament

The Vortice Micro 80 fan features a 2-speed motor for flexible ventilation control.

4.1 Engegada/apagada

Once installed and wired, the fan can be switched on or off via a wall switch connected to its power supply.

4.2 Control de velocitat

The fan's two speeds (low and high) can be selected using a compatible external speed regulator (e.g., a Vortice regulator) or a dual-switch setup, if wired accordingly. The low speed provides a flow rate of 60 m³/h, while the high speed provides 85 m³/h.

Performance curve graph for Vortice Micro 80 fan

Figure 4.1: Performance curve graph for the Vortice Micro 80 fan, illustrating the relationship between pressure (P), flow rate (Q), and power consumption (W) at different operating points.

5. Manteniment

Regular maintenance ensures optimal performance and longevity of your Vortice Micro 80 fan. Always disconnect power before performing any maintenance.

6. Solució De Problemes

If you experience issues with your Vortice Micro 80 fan, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
El ventilador no s'encénSense font d'alimentació
Cablejat solt
El fusible tèrmic s'ha activat
Comproveu el disjuntor/fusible
Verify all electrical connections (by a qualified electrician)
Allow fan to cool down; if problem persists, consult service
Flux d'aire baixBlocked ducting
Impulsor brut
Esborrany damper stuck
Check and clear duct obstructions
Netegeu les pales de l'impel·lent
Assegureu-vos que dampes mou lliurement
Soroll excessiuMuntatge solt
restes a l'impulsor
Problema motor
Premeu els cargols de muntatge
Netejar l'impulsor
If noise persists, contact service

Si el problema persisteix després d'intentar aquestes solucions, poseu-vos en contacte amb un tècnic de servei qualificat.

7. Especificacions

Detailed technical specifications for the Vortice 11638 Centrifugal Extractor Fan:

ParàmetreValor
Número de model11638
MarcaVòrtice
TipusVentilador extractor centrífug
ColorBlanc
MaterialPlàstic ABS
Dimensions (L x A x A)11.7 x 23.9 x 23.9 cm (4.6 x 9.4 x 9.4 polzades)
Pes1.79 kg (3.95 lliures)
Font d'alimentacióCable elèctric
Voltage220-240 V
Max Absorbed Power (High Speed)27 W
Max Absorbed Power (Low Speed)19 W
Max Absorbed Current (High Speed)0.13 A
Max Flow Rate (High Speed)85 m³/h (24 L/s)
Min Flow Rate (Low Speed)60 m³/h (17 L/s)
Max Pressure (High Speed)265 Pa (27 mmH₂O)
Max Pressure (Low Speed)216 Pa (22 mmH₂O)
Sound Pressure Level @ 3m (High Speed)37 dB(A)
Sound Pressure Level @ 3m (Low Speed)28.7 dB(A)
RPM màxim1580
RPM mín1150
Max Ambient Operating Temperature50 °C
País d'origenItàlia

8. Garantia i Suport

Specific warranty information for the Vortice 11638 fan is not available in this manual. Please refer to the product packaging or contact your retailer or the manufacturer directly for warranty details.

For technical support or service inquiries, please contact Vortice customer service or an authorized service center. Ensure you have your product model number (11638) and purchase date available when contacting support.

Documents relacionats - 11638

Preview Vortice MICRO 100 Ventilation Fan Wiring Diagrams - E960057D
Technical wiring diagrams for Vortice MICRO 100 residential ventilation fans, detailing high speed, low speed, and multi-speed selector configurations. Includes component legends and technical specifications. Document reference E960057D.
Preview Manual di Istruzioni Vortice Punto: Modelli M 90, M 100, M 120, M 150
Manuale completo per l'instal·lació, l'ús i el manteniment dels aspiratori Vortice Punt, amb dettagli sui models M 90, M 100, M 120, M 150 i M 100 12V. Inclou avvertenze di sicurezza e specifiche tecniche.
Preview Vortice Axial K - Angol K Installation and User Manual
Comprehensive instruction booklet for Vortice Axial K and Angol K axial centrifugal exhaust units, covering installation, safety, cleaning, and disposal. Includes technical specifications and warranty information.
Preview Sistemes de ventilació Vortice: Guia d'instal·lació i manteniment
Guia completa per a sistemes de ventilació Vortice, que cobreix la instal·lació, la connexió elèctrica, el manteniment i les precaucions de seguretat per a diversos models de ventiladors axials i centrífugs.
Preview Aspirador centrífug Vort Max ES: Manual d'instal·lació i usuari
Manual d'instruccions complet per a l'aspirador centrífug de paret Vortice Vort Max ES, que cobreix la descripció del producte, el compliment de les normes, els avisos de seguretat, la instal·lació, el manteniment, els diagrames de cablejat i l'eliminació.
Preview Vort Quadro: Manual d'Uso e Installazione
Manual completo per i ventiladors centrifughi Vort Quadro di Vortice (Micro 80, 100, Medio, Super). Inclou instruccions d'instal·lació, funcionament, manteniment i seguretat.