1. Introducció
This manual provides essential information for the proper installation, maintenance, and understanding of the Invacare Perfecto Platinum Intake Air HEPA Filter, model 1131249. This filter is designed to ensure optimal performance and air quality for compatible Invacare oxygen concentrators.
2. Producte acabatview
The Invacare Perfecto Platinum Intake Air HEPA Filter (Part Number 1131249) is a critical component for maintaining the purity of the air supplied by your Invacare Perfecto Platinum oxygen concentrator. It is a High-Efficiency Particulate Air (HEPA) filter, designed to capture microscopic particles from the intake air, protecting both the device and the user.

Imatge 1: Invacare Perfecto Platinum Intake Air HEPA Filter, model 1131249, sealed in its clear plastic packaging. An orange label on the filter indicates instructions for use on Platinum 10 and pre-Platinum models, with 'PEEL HERE' tabs.
3. Informació de seguretat
- Always disconnect the oxygen concentrator from the power source before attempting any maintenance or filter replacement.
- Use only genuine Invacare replacement parts to ensure proper fit and performance.
- Do not attempt to clean or reuse a dirty HEPA filter; always replace it with a new one.
- Mantingueu els filtres fora de l'abast dels nens i les mascotes.
4. Instal·lació i configuració
Follow these steps to replace the intake air HEPA filter in your Invacare Perfecto Platinum oxygen concentrator:
- Apagar: Ensure the oxygen concentrator is turned off and unplugged from the electrical outlet.
- Localitza el compartiment del filtre: Refer to your oxygen concentrator's main user manual to locate the intake air filter compartment. This is typically on the back or side of the unit.
- Elimina el filtre antic: Carefully open the filter compartment and remove the old HEPA filter. Dispose of the old filter responsibly.
- Preparar un filtre nou: The new filter may have a protective seal. As indicated on the filter packaging (refer to Image 1), if using on a Platinum 10 model, remove the specified part of the seal. If using on pre-Platinum models, remove the other specified part of the seal. Ensure the correct seal is removed for your specific concentrator model.
- Insereix un filtre nou: Insert the new Invacare HEPA filter into the compartment, ensuring it is seated correctly and securely.
- Compartiment tancat: Tanqueu la tapa del compartiment del filtre.
- Restaura l'alimentació: Plug the oxygen concentrator back into the electrical outlet and turn it on.
Nota: Always consult your specific oxygen concentrator's user manual for detailed, model-specific filter replacement instructions.
5. Funcionament
Once installed, the Invacare Perfecto Platinum Intake Air HEPA Filter operates continuously as part of your oxygen concentrator's air purification system. It passively filters incoming air, removing particulates before they reach the internal components of the concentrator and the patient. No user interaction is required during its operation.
6. Manteniment
Regular replacement of the intake air HEPA filter is crucial for the longevity of your oxygen concentrator and the quality of the oxygen delivered. Invacare recommends the following maintenance schedule:
- Freqüència de substitució: Replace the HEPA filter every 3 mesos, or more frequently if the operating environment is particularly dusty or if indicated by your oxygen concentrator's maintenance alerts.
- Inspecció: Periodically inspect the filter for visible signs of dirt or blockage. A heavily soiled filter can restrict airflow and reduce concentrator efficiency.
Failure to replace the filter as recommended may lead to reduced performance of the oxygen concentrator and potential damage to internal components.
7. Solució De Problemes
If you experience issues after replacing the filter, consider the following:
- Concentrator Not Starting: Ensure the concentrator is properly plugged in and the power switch is on. Verify the filter compartment cover is securely closed.
- Reduced Airflow/Performance: Check that the new filter is correctly seated and not obstructed. Ensure the correct seal was removed for your specific model as per installation instructions.
- Sorolls inusuals: Confirm all covers and filters are securely in place. Loose components can cause vibrations.
If problems persist, consult your oxygen concentrator's main user manual or contact Invacare customer support.
8. Especificacions
| Marca | Invacare |
| Número de model | 1131249 |
| Número de part | 1131249 |
| Número de peça OEM | 1131249 |
| Pes de l'article | 4.2 unces |
| Dimensions del paquet | 9.61 x 6.42 x 2.52 polzades |
| Tipus de filtre | HEPA (High-Efficiency Particulate Air) |
9. Garantia i Suport
For information regarding the warranty of your Invacare Perfecto Platinum Intake Air HEPA Filter or for technical support, please contact Invacare customer service directly. Refer to the documentation provided with your oxygen concentrator for specific contact details or visit the official Invacare weblloc.
Invacare Weblloc: www.invacare.com