Johnson Controls P70AA-118C

Johnson Controls P70AA-118C Condenser Fan Cycling Control

Model: P70AA-118C | Marca: Johnson Controls

1. Introducció i finalview

The Johnson Controls P70AA-118C is a robust pressure control designed for commercial refrigeration and air conditioning applications. Its primary functions include high pressure cut-out control, head-pressure control, and condenser fan cycling. This control is compatible with most common non-corrosive refrigerants and can also be utilized in other non-corrosive fluid applications. It features a single-pole, single-throw (SPST) switch configuration and is designed for a pressure range of 100 to 400 psi.

Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

Figure 1: Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

The P70AA-118C control unit and its dedicated mounting bracket.

Figure 2: The P70AA-118C control unit and its dedicated mounting bracket.

2. Característiques clau

  • All-steel case and cover: Provides long-lasting, rugged protection for internal components, ensuring durability in demanding environments.
  • Sight-set calibrated pressure adjustment: Features a visible pressure scale that is fully adjustable through the range without requiring removal of the cover (on NEMA 1 enclosure models), simplifying setup.
  • Manual reset lockout option: Offers a trip-free lockout mechanism that prevents overriding or resetting until the pressure returns to the specified safe level, enhancing system safety.
  • Variety of available pressure connection styles: Allows for greater flexibility during mounting and adaptation of pressure connections to various field application requirements.
Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

Figure 3: Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

3. Especificacions

EspecificacióValor
Número de modelP70AA-118C
MarcaJohnson Controls
Interval de pressió100 a 400 psi
Longitud capil·lar36 polzades
Flare Nut Size1/4 polzada
Tipus de canviSingle-Pole, Single-Throw (SPST)
MaterialAcer
Pes de l'article1.49 lliures
Dimensions del producte10.25 x 2.75 x 4.37 polzades
Tipus de visualitzacióAnalògic
FabricantJohnson Controls
Data de primera disponibilitat11 d'octubre de 2012
Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

Figure 4: Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

4. Instal·lació

Installation of the P70AA-118C control should be performed by a qualified HVAC technician or electrician in accordance with all local and national electrical codes. Ensure the power supply to the system is disconnected before beginning any installation work.

4.1 Muntatge

Mount the control unit in a location that is easily accessible for adjustments and maintenance, yet protected from physical damage and excessive vibration. Use the provided mounting bracket and appropriate fasteners to secure the unit firmly.

Part inferior view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

Figura 5: Part inferior view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

4.2 Capillary Tube Connection

Carefully route the 36-inch capillary tube to the desired pressure sensing point. Avoid sharp bends or kinks that could damage the tube. Connect the 1/4 inch flare nut to the system's pressure port, ensuring a tight, leak-free seal. Do not overtighten.

En angle view of the P70AA-118C control, highlighting the capillary tube connection.

Figura 6: Angle view of the P70AA-118C control, highlighting the capillary tube connection.

Detail of the capillary tube and 1/4 inch flare nut connection.

Figure 7: Detail of the capillary tube and 1/4 inch flare nut connection.

4.3 Cablejat elèctric

Refer to the wiring diagram provided with the control unit or the system's specific schematics. Connect the electrical wiring to the appropriate terminals within the control's enclosure. Ensure all connections are secure and properly insulated. The P70AA-118C is a single-pole, single-throw (SPST) control.

5. Instruccions de funcionament

Once installed and wired, the P70AA-118C control can be adjusted to the desired operating parameters. The control features a sight-set calibrated pressure adjustment for easy setting.

5.1 Setting Pressure Range

The control allows for adjustment of both the cut-out (high pressure limit) and the differential (the difference between cut-in and cut-out pressures). Use a flat-head screwdriver to adjust the set points visible through the window on the front panel. The scale indicates the pressure in PSI.

5.2 Manual Reset Lockout

If the control is equipped with a manual reset lockout, it will trip and lock the system off if the pressure exceeds a critical threshold. To reset, the pressure must return to a safe level, and then the manual reset button must be pressed. This feature prevents automatic restarts under unsafe conditions.

6. Manteniment

Regular maintenance ensures the longevity and reliable operation of your Johnson Controls P70AA-118C unit. Perform the following checks periodically:

  • Inspecció visual: Check the control unit, capillary tube, and electrical connections for any signs of wear, corrosion, or damage.
  • Neteja: Keep the control unit clean and free from dust, dirt, and debris, which can affect performance.
  • Integritat de la connexió: Assegureu-vos que totes les connexions elèctriques i de pressió estiguin ben ajustades i segures.
  • Comprovació de la funcionalitat: Periodically verify that the control is cycling the fan or cutting out at the set pressure points as expected.

7. Solució De Problemes

If you encounter issues with your P70AA-118C control, consider the following common troubleshooting steps. For complex issues, always consult a qualified technician.

  • Control Not Cycling Fan:
    • Verify power supply to the control.
    • Check pressure settings; ensure they are within the system's operating range and the control's capabilities.
    • Inspect capillary tube for kinks or leaks.
    • Check electrical connections for looseness or corrosion.
  • Lectures de pressió inexactes:
    • Ensure the capillary tube is properly connected and not damaged.
    • Verify the system's actual pressure with a calibrated gauge.
  • Control Trips Frequently:
    • Check for system overpressure conditions.
    • Review the set pressure and differential settings.
    • If equipped, ensure the manual reset lockout is not being triggered by transient pressure spikes.

8. Garantia i Suport

For detailed warranty information, please refer to the official documentation provided by Johnson Controls at the time of purchase or visit the Johnson Controls official website. Support for the P70AA-118C control can be obtained through authorized distributors or by contacting Johnson Controls customer service directly.

Product packaging label displaying the model number P70AA-118C and barcode.

Figure 8: Product packaging label displaying the model number P70AA-118C and barcode (UCC/EAN Code 128: 1078502829326).

Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

Figure 9: Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

Documents relacionats - P70AA-118C

Preview Johnson Controls P70, P72, P170 Series High Pressure Controls
Més detallatview of Johnson Controls PENN P70, P72, and P170 Series Electromechanical Pressure Controls for high-pressure applications. Includes features, applications, selection charts, and cross-references for refrigeration and HVAC systems.
Preview Unitats de paquet individual Johnson Controls Sèrie 100: Guia d'enginyeria
Comprehensive engineering guide for Johnson Controls Series 100 Single Package Units, covering capacities from 70 to 105 tons. Details features, benefits, application data, nomenclature, and technical specifications for these energy-efficient HVAC units.
Preview Guia d'enginyeria d'unitats de paquet individual de la sèrie 100 de Johnson Controls
Guia d'enginyeria completa per a les unitats de paquet únic Johnson Controls Sèrie 100 (70-130 tones). Detalla les característiques, les dades d'aplicació, les especificacions físiques i les dades de rendiment de refrigeració per a solucions de climatització eficients.
Preview Johnson Controls Controller Tool Help for HVAC Systems
This comprehensive help document provides detailed guidance for the Johnson Controls Controller Tool, covering configuration, simulation, commissioning, and troubleshooting of VAV Single Duct and other HVAC applications. It assists professionals in managing building automation systems effectively.
Preview Manual d'informació de l'usuari: Aire condicionat exterior amb sistema split i bomba de calor
Manual d'usuari complet per a les unitats d'aire condicionat i bomba de calor de sistema dividit per a exteriors Johnson Controls Ducted Systems, que cobreix el funcionament, les directrius de seguretat, les funcions del sistema, el manteniment, la resolució de problemes i informació sobre la garantia limitada.
Preview AHE Series Single Piece Air Handler ECM Motor Flex Coil Models Parts List
Detailed parts list and diagram for Johnson Controls AHE Series Single Piece Air Handler with Standard ECM Motor and Flex Coil Models (Style A). Includes component descriptions and part numbers for various models.