1. Introducció
The 3M DBR/Y-6 Underground Electrical Wire Connector Kit is designed for creating secure, moisture-sealed electrical connections in underground environments. This kit provides protection against corrosion and moisture, ensuring reliable performance for various outdoor and underground wiring needs.
Característiques principals:
- Underground electrical wire connector kit.
- Effectively splices and moisture-seals connections.
- Gel-filled tube provides protection against corrosion and moisture.
- Locking fingers hold the Scotchlok™ Connector in position.
- Fàcil instal·lació.
- Suitable for remote-control circuits in irrigation, landscape lighting, septic systems, and other underground electrical wiring applications.
2. Informació de seguretat
Please read and understand all safety instructions before installing or using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Desconnecteu sempre l'alimentació to the circuit before performing any installation, maintenance, or inspection.
- Consult local electrical codes and regulations for proper installation procedures.
- Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi ulleres de seguretat i guants aïllants.
- Ensure all connections are secure and properly sealed to prevent electrical hazards and moisture ingress.
- Do not use this product for applications exceeding its specified voltage o qualificacions actuals.
3. Contingut del paquet
The 3M DBR/Y-6 Underground Electrical Wire Connector Kit typically includes:
- 1 x 3M DBR/Y-6 Underground Electrical Wire Connector Kit (contains components for 2 connections)

This image displays the retail packaging for the 3M DBR/Y-6 kit, which includes two gel-filled tubes and two red wire nuts for making two moisture-resistant electrical connections.
4. Configuració i instal·lació
Follow these steps for proper installation of the 3M DBR/Y-6 connectors:
- Desconnecteu l'alimentació: Ensure all power to the circuit is turned off at the main breaker or fuse box before beginning work.
- Prepareu els cables: Strip approximately 1/2 inch (12-13 mm) of insulation from the ends of the wires to be connected. Ensure the wire ends are clean and free of damage.
- Make Connection: Twist the stripped wire ends together firmly, or use a suitable wire nut (such as the red wire nuts typically included in the kit) to secure the connection. Ensure there are no loose strands.
- Insert into Gel Tube: Carefully insert the connected wires and the wire nut (if used) into the gel-filled tube. The locking fingers inside the tube are designed to hold the connector in position.
- Seal the Tube: Push the wires and connector fully into the tube until the gel completely encapsulates the connection. Ensure the ends of the tube are snug around the wire insulation to create a watertight seal.
- Bury Connection: Once sealed, the connection is ready for underground burial. Ensure the connection is placed in a location that minimizes physical stress.
- Restaura l'alimentació: After all connections are made and secured, restore power to the circuit and test the functionality.
5. Funcionament i ús
The 3M DBR/Y-6 connectors are designed for use in underground electrical wiring applications where protection against moisture and corrosion is critical. Common applications include:
- Sistemes d'aspersió
- Outdoor Lighting (decks, driveways, lamp posts, landscape)
- Septic Systems
- Other underground electrical wiring applications requiring moisture-sealed connections.
These connectors are suitable for low-voltage DC applications up to 24 Volts.
6. Manteniment
Once properly installed, the 3M DBR/Y-6 connectors require minimal maintenance due to their sealed design. However, periodic inspection of the overall wiring system is recommended:
- Periodically inspect exposed wiring and connections for signs of physical damage, degradation, or exposure.
- If any connector appears damaged, compromised, or shows signs of moisture ingress, it should be replaced immediately following the installation steps outlined above.
- Do not attempt to open or repair a sealed connector.
7. Solució De Problemes
If you encounter issues with your electrical connections, consider the following troubleshooting steps:
- Sense alimentació al dispositiu:
- Verifiqueu que el circuit rep alimentació.
- Check all connections for proper seating and crimping. Ensure wires are fully inserted into the connectors.
- Inspect for any broken wires or damaged insulation.
- Connexió intermitent:
- Re-examine wire stripping and connection points. Ensure wires are fully inserted and secured within the connector and sealed tube.
- Ensure the gel-filled tube is properly closed and sealed around the wires.
- Moisture Ingress:
- If moisture is observed inside the tube or at the connection point, the seal may be compromised. Replace the connector immediately.
- Ensure the wires are properly centered and the tube is fully sealed during installation.
Si els problemes persisteixen, consulteu un electricista qualificat.
8. Especificacions
| Atribut | Detall |
|---|---|
| Marca | 3M |
| Número de model | DBR/Y-6 |
| Número de part | DBR/Y-6 |
| Tipus de connector | Underground Wire Connector |
| Material de contacte | Llautó |
| Material d'aïllament | Plàstic |
| Material | Copper, Plastic, Rubber |
| Volum màximtage | 24 volts (CC) |
| Recompte d'unitats | 1 Kit (2 Connections) |
| Pes de l'article | 12.8 unces |
| Dimensions del producte | 6.2 x 4 x 0.95 polzades |
| UPC | 051141341521 |
| Components inclosos | Gel-filled tubes, wire connectors |
| Piles incloses/obligatòries | No |
9. Garantia i Suport