Zurn RK1-350BOF

Zurn Wilkins RK1-350BOF 1-Inch Blow-Out Flush Fitting and O-Rings Repair Kit User Manual

For Wilkins 350 Series Double Check Assemblies

1. Introducció

This manual provides detailed instructions for the proper installation, operation, and maintenance of the Zurn Wilkins RK1-350BOF Blow-Out Flush Fitting and O-Rings Repair Kit. This kit is specifically designed for winterizing 1-inch Wilkins 350 series double check assemblies, facilitating the removal of water from the device and associated lines to prevent freeze damage. Adhering to these instructions will ensure optimal performance and longevity of your plumbing system.

2. Producte acabatview

The Zurn Wilkins RK1-350BOF is a specialized fitting used for the winterization of 1-inch Wilkins 350 series double check backflow preventers. It replaces the internal cartridge housing during the winter months, allowing for easy connection of an air compressor to blow out water from the irrigation lines. The fitting includes two 3/4-inch NPT female taps for air connection and comes with replacement O-rings.

Zurn Wilkins RK1-350BOF blow-out flush fitting with two black O-rings.

Figura 1: An orange plastic Zurn Wilkins RK1-350BOF blow-out flush fitting, designed for winterization, shown with two black O-rings. The fitting features threaded ports for air connection and mounting holes.

3. Informació de seguretat

  • Always shut off the main water supply before beginning any work on the backflow preventer or irrigation system.
  • Wear appropriate personal protective equipment, including safety glasses, when working with tools and pressurized air.
  • Ensure all connections are secure before applying air pressure.
  • Do not exceed the recommended air pressure for your irrigation system components. Consult your irrigation system manual for pressure limits.
  • Mantenir els nens i les mascotes lluny de la zona de treball.

4. Configuració i instal·lació

The RK1-350BOF fitting is designed for straightforward installation without special tools. Follow these steps to install the blow-out fitting for winterization:

  1. Prepara el sistema: Shut off the main water supply to the irrigation system. Open both the inlet and outlet shutoff valves on the Wilkins 350 series double check assembly. Open all four test cocks using a flat-head screwdriver to relieve any residual pressure.
  2. Remove Valve Assembly: Locate the four bolts securing the existing valve assembly (cartridge housing) within the backflow preventer. Using a 3/8-inch wrench or socket, carefully unscrew these four bolts. Gently pry out the valve assembly with a screwdriver, taking care not to damage any internal components or the main body of the backflow preventer.
  3. Install Blow-Out Fitting: Insert the Zurn Wilkins RK1-350BOF blow-out fitting into the cavity where the valve assembly was removed. Ensure the fitting is properly seated.
  4. Secure the Fitting: Reinsert and tighten the four bolts to secure the RK1-350BOF fitting in place. Do not overtighten.
  5. Connect Air Compressor: Attach your air compressor hose to one of the 3/4-inch FNPT (Female National Pipe Taper) ports on the blow-out fitting. You may need to purchase appropriate bushings and air fitting adapters from a hardware or automotive store to match your compressor hose.
  6. Position Valves for Winter: For optimal winter protection, leave the blow-out fitting in place for the duration of the cold season. Position both the inlet and outlet shutoff valves in a half-open, half-closed position. Close all four test cocks. Consider plugging the 3/4-inch FNPT ports on the blow-out fitting to prevent debris or critters from entering the system.

5. Operating Instructions (Winterization)

Once the RK1-350BOF fitting is installed and the air compressor is connected, proceed with the winterization process:

  1. Isolate Zones: Ensure all irrigation zone valves are closed.
  2. Apply Air Pressure: Slowly open the air compressor valve to introduce air into the system. Begin with the zone furthest from the backflow preventer.
  3. Blow Out Zones: Open one irrigation zone valve at a time. Allow air to flow through the zone until water is no longer expelled from the sprinkler heads, indicating the line is clear. Close the zone valve.
  4. Repeat for All Zones: Repeat the process for each irrigation zone until all lines are thoroughly cleared of water.
  5. Desconnectar: Once all zones are blown out, close the air compressor valve and disconnect the hose from the blow-out fitting.

6. Manteniment

  • O-Ring Lubrication: The kit includes O-rings. Before installation, apply a small amount of silicone-based grease (often included with the kit) to the O-rings to ensure a proper seal and prevent premature wear.
  • Inspecció: Annually inspect the blow-out fitting and O-rings for any signs of wear, cracks, or damage. Replace components as necessary.
  • Emmagatzematge: When not in use, store the RK1-350BOF fitting in a clean, dry place away from direct sunlight and extreme temperatures.

7. Solució De Problemes

  • Fuga d'aire: If air leaks are detected around the fitting, ensure the four securing bolts are tightened correctly and the O-rings are properly seated and lubricated. Inspect O-rings for damage and replace if necessary.
  • Dificultat per seure: If the fitting does not seat correctly, ensure the cavity is free of debris and the O-rings are not pinched. Verify that you have the correct model (RK1-350BOF) for your 1-inch Wilkins 350 series assembly.
  • No Air Flow: Check that the main water supply is completely off, all test cocks are closed, and the air compressor is functioning correctly and connected securely. Ensure all irrigation zone valves are closed before opening them one by one.

8. Especificacions

Número de modelRK1-350BOF
Compatibilitat1-inch Wilkins 350 Series Double Check Assemblies
MaterialChloroprene (fitting), Rubber (O-rings)
Nominal Inside Diameter1 polzades
Nominal Outside Diameter1 polzades
Air Connection PortsTwo 3/4-inch FNPT
Dimensions del producteAproximadament 6 x 6 x 6 polzades
Pes de l'articleAproximadament 8 unces
FabricantZurn

9. Garantia i Suport

For information regarding product warranty or technical support, please contact Zurn customer service directly. Refer to the official Zurn weblloc web o l'embalatge del producte per obtenir les dades de contacte i els termes de garantia més actualitzats.

Zurn Weblloc: www.zurn.com

Documents relacionats - RK1-350BOF

Preview Vàlvula reductora de pressió sense plom Zurn NR3XL: guia d'instal·lació, manteniment i reparació
Guia completa per a la vàlvula reductora de pressió sense plom Zurn NR3XL, que cobreix la instal·lació, la inspecció, el manteniment, els procediments de reparació i la resolució de problemes. Inclou les especificacions del producte i informació sobre la garantia.
Preview Adaptador d'espai d'aire ZURN Model AG
L'adaptador de gap d'aire ZURN model AG està dissenyat per al seu ús amb els preventors de reflux de principi de pressió reduïda ZURN WILKINS, garantint una instal·lació correcta de la línia de drenatge en sistemes horitzontals o verticals. Aquest document detalla les seves especificacions, materials i requisits d'instal·lació típics.
Preview Zurn AquaSense ZER-SM Series Automatic Battery-Powered Flush Valve Manual
Comprehensive manual for Zurn AquaSense ZER-SM series automatic battery-powered flush valves, covering installation, operation, maintenance, troubleshooting, and parts breakdown for models like ZER6000-SM, ZER6200-SM, ZER6003-SM, and ZER6203-SM.
Preview Muntatge de la vàlvula reductora de pressió Zurn Wilkins ZW209FP: instal·lació, funcionament i manteniment
Guia completa del conjunt de vàlvules reductores de pressió de protecció contra incendis Zurn Wilkins ZW209FP, que cobreix la instal·lació, la posada en marxa, el funcionament, les característiques de flux i els procediments de manteniment. Inclou instruccions detallades per a la vàlvula principal i la vàlvula pilot PV-PRD.
Preview Especificacions i instal·lació del conjunt de disjuntors de buit a pressió Zurn Wilkins Model 720A
Informació detallada sobre el conjunt de trencador de buit a pressió Zurn Wilkins Model 720A, incloent-hi la seva aplicació, compliment de les normes, materials, característiques, dimensions, pesos, característiques de flux i pautes d'instal·lació tant per a ús interior com exterior.
Preview ZURN AquaSense AV ZER Series Automatic Sensor-Operated Flushometer Manual
Installation, operation, maintenance, and parts manual for the ZURN AquaSense AV ZER Series automatic sensor-operated, battery-powered flushometer. Includes troubleshooting, repair kits, and technical specifications.