APC AR7580A

Manual d'instruccions del gestor de cables vertical APC AR7580A

Model: AR7580A

1. Introducció

The APC AR7580A Vertical Cable Manager is designed to provide efficient and organized cable routing within Netshelter racks. This product helps maintain a clean and functional server environment by managing network and power cables, reducing clutter, and improving airflow. This manual provides essential information for the proper installation, use, and maintenance of your AR7580A Vertical Cable Manager.

Key features include durable construction and high efficiency in cable organization.

2. Producte acabatview

The AR7580A Vertical Cable Manager consists of a robust frame with multiple cable fingers and brush strips designed to guide and secure cables. It is supplied as a 2-quantity set, allowing for comprehensive cable management solutions within your rack.

APC AR7580A Vertical Cable Manager, front view

Figura 1: Frontal view of the APC AR7580A Vertical Cable Manager, showing the main structure and cable routing fingers.

APC AR7580A Vertical Cable Manager, side view with cable fingers

Figura 2: lateral view of the APC AR7580A Vertical Cable Manager, highlighting the individual cable fingers for organized routing.

3. Informació de seguretat

Please read and understand all safety instructions before installing or using this product. Failure to do so may result in injury or damage to equipment.

  • Always ensure the rack is stable and properly secured before installing any accessories.
  • Utilitzeu les eines adequades per a la instal·lació.
  • Do not overload the cable manager with excessive cables, as this can impede airflow and strain mounting points.
  • Keep hands and fingers clear of moving parts during installation.

4. Contingut del paquet

Verifiqueu que tots els components siguin presents abans de començar la instal·lació:

  • 2 x APC AR7580A Vertical Cable Managers
  • Mounting hardware (screws, cage nuts, washers - typically included with Netshelter racks or cable manager)

Si falta algun article o està malmès, contacteu immediatament amb el vostre proveïdor.

5. Configuració i instal·lació

The APC AR7580A Vertical Cable Manager is designed for easy installation into APC Netshelter racks. Follow these steps for proper mounting:

  1. Prepareu el bastidor: Ensure the Netshelter rack is properly assembled and secured. Identify the desired location for the vertical cable managers, typically along the side channels of the rack frame.
  2. Position the Manager: Align one of the vertical cable managers with the mounting holes on the rack frame. The cable fingers should face inwards towards the rack equipment.
  3. Secure the Manager: Using the appropriate mounting hardware (e.g., M6 screws and cage nuts), attach the cable manager to the rack frame. Start by loosely fastening a few screws at the top and bottom, then proceed to secure all mounting points. Ensure the manager is level and firmly attached.
  4. Repeat for Second Manager: Install the second vertical cable manager on the opposite side of the rack or in another desired location, following the same procedure.
APC AR7580A Vertical Cable Manager installed in a rack, door open

Figure 3: The AR7580A Vertical Cable Manager installed within a Netshelter rack, viewed with the side door open.

Close-up of cables routed through the APC AR7580A Vertical Cable Manager

Figura 4: Detall view of cables neatly routed through the cable management fingers of the AR7580A.

6. Cable Routing Guidelines

Once installed, the vertical cable managers facilitate organized cable routing:

  • Separate Cable Types: Whenever possible, separate power cables from data cables to minimize electromagnetic interference.
  • Use Cable Fingers: Route cables through the individual fingers of the manager. This provides support and prevents cables from sagging or obstructing airflow.
  • Eviteu els revolts tancats: Ensure cables are not bent too sharply, especially fiber optic cables, to prevent damage and signal loss.
  • Leave Service Loops: Allow for a small amount of slack (service loop) in cables to facilitate future maintenance or equipment changes without disconnecting other devices.
  • Secure with Ties: Use hook-and-loop cable ties (not included) to bundle cables within the manager for additional neatness and security. Avoid using plastic zip ties that can overtighten and damage cables.
Organized cables within a rack using the APC AR7580A Vertical Cable Manager

Figura 5: Un example of well-managed cables within a rack, utilizing the AR7580A for vertical organization.

7. Manteniment

The APC AR7580A Vertical Cable Manager requires minimal maintenance to ensure continued performance:

  • Inspecció periòdica: Periodically inspect the cable managers for any signs of damage, loose mounting, or excessive cable buildup.
  • Neteja: Dust and debris can accumulate over time. Use a soft, dry cloth to wipe down the surfaces of the cable manager. For stubborn dirt, a slightly damp cloth can be used, ensuring no moisture enters sensitive equipment.
  • Cable Reorganization: As equipment changes or additions occur, review and reorganize cables as needed to maintain optimal airflow and accessibility.

8. Solució De Problemes

Most issues related to cable management can be resolved by reviewing installation and routing practices.

  • Cable Congestion: If cables are too tightly packed, they can impede airflow and make future maintenance difficult. Re-route cables, potentially utilizing additional cable management accessories if necessary.
  • Loose Manager: If the cable manager feels loose, check all mounting screws and ensure they are securely tightened.
  • Cables danyats: If cables appear pinched or damaged, inspect the routing path and ensure no sharp edges or excessive pressure points are present. Replace damaged cables immediately.

9. Especificacions

AtributValor
MarcaAPC
Número de modelAR7580A
Dimensions del producte37.75 x 6.5 x 8 polzades (95.89 x 16.51 x 20.32 cm)
Pes de l'article9.9 lliures (4.49 kg)
ColorNegre
MaterialPlàstic
Dispositius compatiblesServer (Netshelter Racks)
Quantitat2

10. Garantia i Suport

For warranty information or technical support regarding your APC AR7580A Vertical Cable Manager, please refer to the official APC website or contact APC customer service directly. Keep your purchase receipt and product model number (AR7580A) available when contacting support.

APC Customer Support: www.apc.com/us/en/support/

Documents relacionats - AR7580A

Preview APC NetShelter VL Enclosure Front Door AR7002 Installation Guide
Comprehensive installation guide for the APC NetShelter VL Enclosure Front Door (AR7002). Learn how to install, remove, and reverse the door with step-by-step instructions and detailed diagram descriptions.
Preview Manual d'instal·lació i usuari d'APC NetShelter AR1000, AR1001, AR1100
Aquest manual proporciona instruccions detallades per a la instal·lació, configuració i manteniment dels armaris de rack NetShelter d'American Power Conversion (APC), inclosos els models AR1000, AR1001 i AR1100. Cobreix informació sobre l'inventari de productes, els avisos, la configuració, l'anivellament, l'estabilització i la garantia.
Preview Instruccions d'instal·lació de la porta principal APC NetShelter VL AR7002 | Schneider Electric
Instruccions d'instal·lació detallades per a la porta frontal APC NetShelter VL AR7002. Apreneu a instal·lar, treure i invertir la porta del vostre armari.
Preview Instruccions d'instal·lació de la porta frontal de l'armari APC NetShelter VL AR7002
Guia d'instal·lació completa per a la porta frontal de l'armari APC NetShelter VL (AR7002). Cobreix l'inventari, la instal·lació, l'extracció i els procediments de reversió de la porta amb descripcions textuals detallades dels diagrames.
Preview Guia d'instal·lació del sensor de fuites de corda APC NetBotz NBES0308
Instruccions d'instal·lació per al sensor de fuites de corda APC NetBotz (NBES0308), que detallen l'inventari, la configuració i els requisits de connexió per als monitors de rack NetBotz 450 i 550.
Preview Guia d'instal·lació de l'APC Smart-UPS 1200/1500 VA
Aquesta guia d'instal·lació proporciona instruccions de seguretat essencials i procediments pas a pas per instal·lar unitats APC Smart-UPS 1200/1500 VA Rack-Mount 1U. Obteniu informació sobre les característiques del producte, la seguretat de la bateria i la instal·lació en rack.