YORK CECOMINOD071178

YORK Furnace Control Circuit Board User Manual

Model: CECOMINOD071178 (Replacement for 031-01234-000)

1. Introducció

This manual provides essential information for the safe and effective installation, operation, and maintenance of your new YORK Furnace Control Circuit Board, Model CECOMINOD071178. This board serves as a direct replacement for the original 031-01234-000 board, designed to manage the various functions of your furnace system. Please read this manual thoroughly before proceeding with any installation or service.

2. Informació de seguretat

La instal·lació, l'ajustament, l'alteració, el servei o el manteniment inadequats poden causar danys a la propietat, lesions personals o la pèrdua de la vida. La instal·lació i el servei han de ser realitzats per un instal·lador qualificat, una agència de servei o el proveïdor de gas.

3. Producte acabatview

The YORK Furnace Control Circuit Board (Model CECOMINOD071178) is a critical component responsible for controlling the sequence of operations in your furnace. It manages functions such as ignition, fan operation, and safety shutdowns. This board is an upgraded replacement designed to be compatible with systems originally using the 031-01234-000 board.

Image of the York Furnace Control Circuit Board, model 031-01234-000, showing various electronic components, relays, and connection terminals.
This image displays the complete layout of the York Furnace Control Circuit Board. Key components visible include various resistors, capacitors, integrated circuits, relays, and terminal blocks for wiring connections. The board features labels for different functions such as 'REMOTE SWITCH', 'FAN SPEED', 'Y/Y2', 'W', 'R', 'G', 'C', 'HI COOL', 'LO COOL', 'HEAT', 'XFMR', and 'NEUTRALS', indicating its role in managing furnace operations. A fuse labeled '5' is also visible near the bottom.

While this board is a functional replacement, its physical layout and mounting hole configuration may differ from the original 031-01234-000 board. It is manufactured by White-Rodgers and may carry part number 50A56-956.

4. Configuració i instal·lació

Segueix aquests passos amb cura per a una instal·lació correcta:

  1. Desconnexió d'alimentació: Turn off all electrical power to the furnace at the main circuit breaker or fuse box. Verify power is off using a voltage metre.
  2. Documentar el cablejat existent: Before disconnecting any wires from the old control board, take clear photographs of all connections. Label each wire and its corresponding terminal on the old board. This is crucial for correct re-connection.
  3. Treure la placa antiga: Carefully disconnect all wires and remove the old control board from the furnace control box. Note the mounting method.
  4. Munta una nova placa: The new board may have different mounting hole locations. You may need to drill new holes in the control box to secure the new board. The board typically comes with nylon standoffs and snap-tabs. Position the new board, mark the new hole locations, and drill appropriate pilot holes (e.g., 3/16" for nylon standoffs). Ensure the board is securely mounted.
  5. Connecteu el cablejat: Refer to your documented wiring (photos and labels) and the wiring diagram provided with the new control board. Connect each wire to its corresponding terminal on the new board.
  6. Transformer Polarity (Crucial): Some replacement boards, including this one, may have a reverse polarity design for the 24V transformer leads compared to the original York board. If your furnace does not operate after installation and displays a

    Documents relacionats - CECOMINOD071178

    Preview York DGAA & DGAH High Efficiency Gas Furnace: User, Maintenance, and Service Manual
    Comprehensive guide for York DGAA and DGAH High Efficiency Sealed Combustion Gas Furnaces, covering safety, installation, operation, maintenance, troubleshooting, and parts.
    Preview York TM9E Series Residential Gas Furnace Installation Manual
    Comprehensive installation manual for York TM9E Series single-stage ECM residential gas furnaces. Covers safety, ductwork, gas piping, electrical, venting, start-up, and diagnostics for these high-efficiency HVAC units.
    Preview Llista de peces i diagrames dels forns de gas natural York sèrie PS9
    Llista completa de peces i diagrames de components per als forns de gas natural horitzontal/de flux descendent del 90% de la sèrie York PS9, inclosos els números de model PS9B12N060DH11A, PS9B12N080DH11A, PS9C16N080DH11A, PS9C16N100DH11A, PS9C20N100DH11A i PS9D20N120DH11A.
    Preview Llista de peces dels forns de gas natural horitzontal/de flux descendent del 90% de la sèrie York PS9
    Llista completa de peces i diagrames per als forns de gas natural horitzontal/de flux descendent del 90% de la sèrie York PS9, inclosos els números de model PS9B12N060DH11A, PS9B12N080DH11A, PS9C16N080DH11A, PS9C16N100DH11A, PS9C20N100DH11A i PS9D20N120DH11A. Inclou la identificació dels components i els números de peça.
    Preview Banyera independent YORK-Y409: Guia d'instal·lació, manteniment i seguretat
    Guia completa per a la banyera independent YORK-Y409, que cobreix les característiques del producte, instruccions detallades d'instal·lació (amb i sense accés sota terra), consells de manteniment, procediments de neteja, eliminació de ratllades i avisos de seguretat importants. Inclou les dimensions del producte i informació sobre la garantia.
    Preview York Residential Multi-position Gas Furnaces (33" Models) User's Information Manual
    This user's information manual provides comprehensive guidance for York residential multi-position gas furnaces, 33-inch models. It covers essential safety precautions, installation examination, start-up and shutdown procedures, operating instructions, maintenance guidelines, troubleshooting, and warranty details. The manual is designed for homeowners and service professionals, ensuring safe and efficient operation of the furnace.