Cisco WS-C2960S-48TD-L

Cisco Catalyst 2960S-48TD-L Ethernet Switch User Manual

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the Cisco Catalyst 2960S-48TD-L Ethernet Switch.

1. Producte acabatview

The Cisco Catalyst 2960S-48TD-L is a fixed-configuration, stackable Gigabit Ethernet switch designed for enterprise, mid-market, and branch office networks. It provides 48 Gigabit Ethernet ports and offers advanced Layer 2 switching capabilities, including Cisco FlexStack stacking and Power over Ethernet Plus (PoE+) support. This switch is engineered for ease of use, secure business operations, and improved sustainability.

1.1 Característiques del panell frontal

Davant view of the Cisco Catalyst 2960S-48TD-L Ethernet Switch showing 48 Gigabit Ethernet ports and uplink ports.

Figura 1: Tauler frontal View. This image displays the front panel of the Cisco Catalyst 2960S-48TD-L switch, featuring 48 Gigabit Ethernet ports for network connectivity and two SFP+ uplink ports on the right side for high-speed connections to the network core or other switches. Status LEDs are visible above each port, indicating port status, speed, and PoE activity.

1.2 Característiques del panell posterior

posterior view of the Cisco Catalyst 2960S-48TD-L Ethernet Switch showing power input, console port, and fan exhaust.

Figura 2: Panell posterior View. This image shows the rear panel of the Cisco Catalyst 2960S-48TD-L switch, including the AC power input connector, a console port for out-of-band management, and ventilation grilles for cooling. The model number and serial number labels are also visible for identification.

2. Configuració i instal·lació

2.1 Desembalatge i inspecció

Carefully unpack the switch and verify that all components are present and undamaged. The package should contain:

  • Cisco Catalyst 2960S-48TD-L Ethernet Switch
  • Cable d'alimentació CA
  • Rack-mount kit (if included)
  • Documentació (Guia d'inici ràpid, Informació de seguretat)

If any items are missing or damaged, contact your Cisco representative immediately.

2.2 Muntatge en bastidor

The switch can be mounted in a standard 19-inch equipment rack. Follow these steps:

  1. Attach the rack-mount brackets to the sides of the switch using the provided screws.
  2. Align the switch with the rack posts and secure it using the rack screws.
  3. Ensure adequate airflow around the switch for proper cooling.

2.3 Connexió de potència

Connect the supplied AC power cord to the power connector on the rear panel of the switch and then to a grounded AC power outlet. The switch will automatically power on once connected.

2.4 Connexions de xarxa

Connect Ethernet cables from your network devices (computers, servers, other switches) to the RJ-45 ports on the front panel. For high-speed uplinks, use appropriate SFP+ transceivers and fiber optic cables in the dedicated SFP+ slots.

3. Instruccions de funcionament

3.1 Encès inicial

Upon connecting power, the switch will initiate its boot sequence. Observe the system LED on the front panel. It will cycle through various states (amber, green) and eventually turn solid green, indicating successful boot-up and readiness for operation.

3.2 Accés a l'interruptor

You can access and configure the switch using several methods:

  • Port de la consola: Connect a console cable (RJ-45 to DB-9) from your management workstation to the console port on the rear panel. Use a terminal emulation program (e.g., PuTTY, Tera Term) with settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.
  • Telnet/SSH: Once the switch has an IP address configured, you can access it remotely via Telnet (less secure) or SSH (recommended for security) using its IP address.
  • Web Interface (HTTP/HTTPS): If enabled and configured, you can access the switch's web-based management interface by entering its IP address into a web navegador.

3.3 Configuració bàsica

Refer to the Cisco IOS Software Configuration Guide for detailed configuration instructions. Common initial configurations include:

  • Setting the hostname
  • Configuring IP addresses for management interfaces (VLAN 1 by default)
  • Setting up user accounts and passwords
  • Enabling SSH for secure remote access
  • Configuring VLANs and port assignments

4. Manteniment

4.1 Neteja

Periodically clean the exterior of the switch with a soft, dry cloth. Ensure that the ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating. Do not use liquid or aerosol cleaners directly on the switch.

4.2 actualitzacions de microprogramari

Regularly check the Cisco website for the latest firmware (IOS) updates for your switch model. Keeping the firmware up-to-date ensures optimal performance, security, and access to new features. Follow Cisco's recommended procedures for firmware upgrades to avoid service interruptions.

5. Solució De Problemes

5.1 Problemes d'energia

  • Sense energia: Verify the power cord is securely connected to both the switch and the power outlet. Check the power outlet with another device.
  • System LED Off: If the system LED is off after connecting power, the switch may not be receiving power or could be faulty.

5.2 Problemes de connectivitat de xarxa

  • Port LED Off: Ensure the Ethernet cable is properly connected at both ends. Check the connected device for power and proper operation.
  • No Network Access: Verify IP configuration on the switch and connected devices. Check VLAN assignments and ensure routing is correctly configured if necessary.

5.3 Problemes de rendiment

  • Slow Network: Check for high CPU utilization on the switch. Inspect port statistics for errors, collisions, or excessive broadcasts. Consider upgrading to higher-speed uplinks if bandwidth is a bottleneck.
  • Connectivitat intermitent: Inspect cables for damage. Check for duplex mismatches between the switch port and the connected device.

6. Especificacions tècniques

CaracterísticaValor
MarcaCisco
Número de modelWS-C2960S-48TD-L
Nombre de Ports48
Tipus d'interfíciePoE
Velocitat de transferència de dades1000 Megabits Per Second (1 Gigabit)
Pes16.15 lliures
Material de la caixaMetall
Classificació de temperatura superior40 graus centígrads
Dispositius compatiblesEscriptori
UPC808114331368, 799599493040

7. Garantia i Suport

This Cisco product is covered by Cisco's standard warranty. For detailed warranty information, technical support, and additional resources, please visit the official Cisco website or contact your authorized Cisco partner. Ensure you have your product's serial number available when seeking support.

Documents relacionats - WS-C2960S-48TD-L

Preview Guia de transició de les sèries Cisco Catalyst 2960/2960-SF/2960-S
Una guia per a la transició dels models de commutadors Cisco Catalyst més antics a la sèrie Cisco Catalyst 2960-L, que destaca les funcions i les rutes de migració.
Preview Coloració BSS i OBSS-PD: Guia de gestió d'interferències de Wi-Fi 6
Aquest document ofereix un sobreview de les funcions de coloració BSS i detecció de paquets BSS superposats (OBSS-PD) a Wi-Fi 6 (802.11ax), que detalla la seva funcionalitat, configuració i verificació per a equips de xarxa sense fil de Cisco.
Preview Guia de desplegament de Cisco FlexConnect Bonjour per al servei Cisco DNA
Una guia completa que detalla la implementació de Cisco DNA Service per a Bonjour amb xarxes sense fil Cisco FlexConnect, que permet la descoberta i distribució de serveis sense problemes en entorns cablejats i sense fil.
Preview Trunking entre commutadors de les sèries Catalyst 4500/4000, 5500/5000 i 6500/6000 mitjançant encapsulació 802.1Q amb programari de sistema Cisco CatOS
Una guia tècnica que detalla la implementació i configuració de l'enllaç troncal IEEE 802.1Q en commutadors de les sèries Cisco Catalyst 4500/4000, 5500/5000 i 6500/6000 mitjançant el programari del sistema CatOS, incloent-hi exemples pas a pas.amples and common error resolution.
Preview Notes de la versió del commutador Cisco Catalyst sèrie 3650: Cisco IOS XE Denali 16.2.x
This document provides release notes for the Cisco Catalyst 3650 Series Switch running Cisco IOS XE Denali 16.2.x software. It details new hardware and software features, important notes, and supported hardware models.
Preview Commutadors Cisco Catalyst de les sèries 3560-CX i 2960-CX: característiques, especificacions i preguntes freqüents
Un document complet de preguntes freqüents que detalla les característiques, les especificacions, les comparacions, el muntatge, el maquinari, el programari, la seguretat, l'alimentació, l'eficiència energètica i la informació de garantia dels commutadors de xarxa compactes Cisco Catalyst sèries 3560-CX i 2960-CX.