Introducció
This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Carrier HK61EA005 OEM Replacement Furnace Control Board. Please read this manual thoroughly before proceeding with any installation or service procedures. Retain this manual for future reference.
Informació de seguretat
ADVERTIMENT: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment. Failure to follow these instructions could result in property damage, personal injury, or death.
- Always disconnect power to the furnace before installing or servicing the control board.
- Verifiqueu que totes les connexions de cablejat siguin segures i correctes d'acord amb les especificacions del fabricant del forn.
- Utilitzeu l'equip de protecció individual (EPI) adequat, incloent-hi ulleres i guants de seguretat.
- Ensure proper grounding of the furnace system.
Producte acabatview
The Carrier HK61EA005 is an OEM replacement furnace control board designed to manage the operational sequences of a furnace, including ignition, fan control, and safety monitoring. This board is compatible with various Carrier furnace models.

Figura 1: Carrier HK61EA005 Furnace Control Board. This image displays the circuit board with various terminals, jumpers, and components. Key features include the "EASY SELECT" jumper settings for system type, ON/OFF DELAY settings, and terminal blocks for wiring connections such as D, R, W, W2, Y, Y2, G, O, and C. A yellow jumper wire is visible connecting two pins on the board.
Configuració i instal·lació
- Desconnexió d'alimentació: Desconnecteu tota l'alimentació elèctrica del forn al quadre de servei principal. Verifiqueu que l'alimentació estigui apagada utilitzant un vol...tage metre.
- Accés al tauler antic: Obriu el panell d'accés al forn per localitzar la placa de control existent.
- Cablejat de documents: Before disconnecting any wires, take clear photographs or make a detailed diagram of all wiring connections to the old control board. Note the position and color of each wire.
- Desconnectar els cables: Desconnecteu amb cura tots els cables i connectors de l'antiga placa de control.
- Treure la placa antiga: Desmunteu la placa de control antiga del xassís del forn. Fixeu-vos en com estava fixada (cargols, clips, etc.).
- Instal·lar la placa nova: Mount the new HK61EA005 control board in the same location and orientation as the old board. Ensure it is securely fastened.
- Connecteu el cablejat: Refer to your photographs or diagram and carefully reconnect all wires and connectors to the corresponding terminals on the new control board. Double-check each connection for accuracy and tightness.
- Configuració del pont: Configure the "EASY SELECT" jumpers and ON/OFF DELAY jumpers on the new board to match the settings of the original board or the furnace manufacturer's specifications. These settings typically determine the system type (e.g., AC, HP) and fan delay times. Refer to the furnace wiring diagram for specific requirements.
- Tanca el panell d'accés: Un cop verificades totes les connexions, tanqueu i assegureu el panell d'accés al forn.
- Restaura l'alimentació: Restableix l'alimentació elèctrica a la caldera al quadre de servei principal.
Instruccions de funcionament
After successful installation and power restoration, the furnace control board will initiate its normal operating sequence. The board manages the following functions:
- Seqüència d'encesa: Controls the gas valve and igniter for safe furnace startup.
- Control del ventilador: Manages the indoor blower motor operation based on heating or cooling demands and delay settings.
- Monitorització de seguretat: Continuously monitors various safety sensors (e.g., flame sensor, limit switches) and will shut down the furnace if a fault is detected.
- Interfície del termòstat: Communicates with the thermostat to receive heating and cooling calls.
For specific operational details, refer to your furnace's primary instruction manual.
Manteniment
The HK61EA005 control board itself requires no routine maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and proper function. This includes:
- Substitució del filtre d'aire: Replace or clean the furnace air filter regularly (typically every 1-3 months) to ensure proper airflow.
- Annual Professional Inspection: Have a qualified HVAC technician inspect and service your furnace annually.
- Clean Flame Sensor: A dirty flame sensor can cause intermittent furnace operation. This should be cleaned by a qualified technician.
Always disconnect power to the furnace before performing any maintenance.
Resolució de problemes
If the furnace is not operating correctly after installing the new control board, consider the following troubleshooting steps:
- Sense energia:
- Comproveu l'interruptor del forn.
- Ensure the furnace disconnect switch is in the "ON" position.
- Verificar tots els de baix volumtage i alt voltagLes connexions a la placa de control són segures.
- El forn no s'encén:
- Confirm the thermostat is set to "HEAT" and the temperature is above the ambient room temperature.
- Check for error codes on the control board (if applicable, refer to your furnace manual for code interpretations).
- Assegureu-vos que la vàlvula de subministrament de gas està oberta.
- Verify the flame sensor is clean and properly positioned.
- Fan Not Operating Correctly:
- Check the "ON/OFF DELAY" jumper settings on the control board.
- Ensure the thermostat fan setting is correct (AUTO/ON).
- Verify the fan motor connections to the control board.
- Codis d'error: Many control boards have diagnostic LEDs that flash codes to indicate specific faults. Consult your furnace's original manual for a list of error codes and their meanings.
If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for assistance.
Especificacions
| Número de model | HK61EA005 |
| Alternate Model Number | CECOMINOD058414 |
| Marca | Carrier (OEM Replacement) |
| Dimensions del producte | 6 x 6 x 6 polzades |
| Pes | 0.01 unces |
| Data de primera disponibilitat | 8 d'octubre de 2013 |
Garantia i Suport
For warranty information regarding this OEM replacement part, please refer to the terms provided by your original point of purchase or the specific warranty documentation included with the product. For technical support, it is recommended to consult a qualified HVAC technician or the original furnace manufacturer's support resources.