Introducció
This manual provides essential information for the safe and proper installation, operation, and maintenance of the Lennox 97L4801 OEM Replacement Furnace Control Board. This control board is designed to manage the ignition sequence, flame sensing, and various timing functions for gas-fired non-integrated forced-air furnaces, boilers, and cooking appliances. Please read all instructions carefully before proceeding with installation or operation.
Informació de seguretat
ADVERTIMENT: La instal·lació, l'ajustament, l'alteració, el servei o el manteniment inadequats poden causar danys a la propietat, lesions personals o la pèrdua de la vida. La instal·lació i el servei han de ser realitzats per un instal·lador qualificat, una agència de servei o el proveïdor de gas.
- Always disconnect electrical power to the furnace before servicing to prevent electrical shock.
- Assegureu-vos que totes les connexions de cablejat compleixin els codis elèctrics locals i nacionals.
- Verify proper grounding of the furnace and control board.
- Do not operate the furnace if any part has been submerged in water. Immediately call a qualified service technician to inspect the furnace and replace any part of the control system and gas control that has been submerged in water.
- Handle the control board with care to avoid damage from static electricity.
Configuració i instal·lació
The Lennox 97L4801 control board is an OEM replacement part. While designed for compatibility, variations may exist between older and newer board designs. Professional installation is highly recommended.
Passos d'instal·lació:
- Desconnecteu l'alimentació: Desconnecteu tota l'alimentació elèctrica del forn al quadre de servei principal.
- Tauler de control d'accés: Localitzeu i obriu el panell d'accés al forn per exposar la placa de control existent.
- Cablejat de documents: Before disconnecting any wires, take clear photographs or make detailed diagrams of all existing wiring connections to the old control board. Pay close attention to the thermostat wires and main power connections.
- Desconnectar els cables: Carefully disconnect all wires from the old control board. Label each wire as it is removed to ensure correct re-connection.
- Treure la placa antiga: Desmunteu la placa de control antiga de la seva posició.
- Instal·lar la placa nova: Mount the new Lennox 97L4801 control board in the same location. Ensure it is securely fastened.
- Connecteu el cablejat: Reconnect all wires to the new control board according to your documentation. Note that the new board may have different connector configurations (e.g., 4-pin and 12-pin connectors instead of 6-pin and 9-pin) and the thermostat wire order might differ. Use any provided adapter wires if necessary. Ensure all connections are firm and correct.
- Verifica les connexions: Double-check all wiring against your documentation and the new board's labels.
- Restaura l'alimentació: Tanqueu el panell d'accés al forn i restableixi l'alimentació elèctrica al forn.
- Prova de funcionament: Initiate a heating cycle to verify proper furnace operation. Observe the ignition sequence and overall performance.

Image: Comparison of an older Lennox furnace control board (left) and the new 97L4801 replacement board (right), highlighting potential differences in layout and connector types. The new board may require adapting existing wiring due to changes in pin configurations and thermostat wire placement.
Instruccions de funcionament
The Lennox 97L4801 control board operates automatically once installed and power is supplied. It manages the furnace's heating and cooling cycles based on thermostat demands.
- Ensure your thermostat is set to the desired mode (Heat/Cool) and temperature.
- The control board will initiate the appropriate sequence:
- Cicle de calefacció: Inducer motor activation, hot surface igniter warm-up, gas valve opening, flame sensing, and blower motor activation after a heat delay.
- Cicle de refrigeració: Blower motor activation upon demand from the thermostat.
- The board incorporates various safety features, including flame failure response and limits for heat and cool delays.
Manteniment
The control board itself requires no routine maintenance. However, regular maintenance of the entire furnace system is crucial for its longevity and efficient operation.
- Have your furnace inspected annually by a qualified HVAC technician.
- Regularly replace or clean your furnace air filter as recommended by your furnace manufacturer.
- Mantingueu la zona al voltant del forn lliure d'obstacles i materials combustibles.
Resolució de problemes
The 97L4801 control board features diagnostic indicators to assist in identifying operational issues. Refer to your furnace's specific diagnostic chart for detailed interpretations.
Common Diagnostic Codes (Refer to board labels for specifics):
- Flaix lent: Indicates a specific fault condition, often related to a safety limit being open or a watch guard burner issue.
- Flash ràpid: May indicate a different fault, such as a reverse polarity condition or a specific heat demand issue.
- Alternate Flash: Suggests a more complex issue, potentially involving simultaneous safety limits or other system errors.
Passos generals per a la resolució de problemes:
- No Heat/No Cool: Check thermostat settings, ensure power is supplied to the furnace, and verify circuit breakers.
- Furnace Not Firing: Observe the diagnostic light on the control board. Check for proper gas supply and ensure the igniter is functioning.
- Continuous Cycling: This could indicate a faulty limit switch, flame sensor, or an issue with the thermostat.
- El ventilador no funciona: Check for proper wiring to the blower motor and ensure the thermostat is calling for fan operation.
Si els passos de resolució de problemes no resolen el problema, poseu-vos en contacte amb un tècnic de climatització qualificat per a un diagnòstic i una reparació més detallats.
Especificacions
| Característica | Detall |
|---|---|
| Número de model | 97L4801 |
| Marca | Lennox |
| Dimensions del producte | 6 x 6 x 6 polzades |
| Pes de l'article | 1.5 lliures |
| Tipus d'encesa | Ignició de superfície calenta |
| Compatibilitat del tipus de combustible | Natural, Manufactured, Mixed, Liquefied Petroleum, and Liquid Propane Gas |
| Tipus de sensació de flama | Remote, Integrated |
| Seqüència d'encesa | 4-Trial Prepurge Time 15 Second |
| Temps de resposta a la fallada de flama | 2 segons |
| Entrada Voltage | 25 Volt AC at 50/60 Hertz |
| Qualificació de temperatura | -40 to 175 Deg F |
| Gamma d’humitat | 5 to 93 Percent Relative Humidity |
| Auto-Reset Time | 60 minut |
Informació de la garantia
This Lennox 97L4801 OEM Replacement Furnace Control Board is covered by the manufacturer's standard warranty. Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided with your original furnace or contact Lennox customer support.
Atenció al client