Comark KM28KIT

Comark KM28 Thermocouple Kit User Manual

Model: KM28KIT

1. Introducció

This manual provides instructions for the safe and effective use of the Comark KM28 Thermocouple Kit. This kit is designed for accurate temperature measurement, particularly in food service applications, and includes the KM28 thermometer, a PK19M probe, and a CRS/5 protective boot.

Si us plau, llegiu aquest manual detingudament abans de fer servir el dispositiu i conserveu-lo per a futures consultes.

Comark KM28 Thermometer Kit with PK19M Probe and protective boot

Figura 1: The Comark KM28 Thermocouple Kit, showing the KM28 thermometer unit, the PK19M probe, and the red coiled cable connecting them. The thermometer is encased in a blue protective boot.

2. Components del kit

The Comark KM28 Thermocouple Kit includes the following items:

  • KM28 Thermometer: The main display unit for temperature readings.
  • PK19M Probe: A Type K thermocouple probe for temperature sensing.
  • CRS/5 Protective Boot: A durable blue silicone boot designed to protect the KM28 thermometer.
Comark KM28 Thermometer unit in protective boot

Figura 2: Primer pla view of the Comark KM28 thermometer unit, displaying "155.0 °F" and featuring "On/Off" and "°C/°F" buttons.

PK19M Thermocouple Probe with coiled cable

Figura 3: The PK19M thermocouple probe, featuring a blue handle, a stainless steel shaft, a red coiled cable, and a yellow sub-miniature connector.

3. Instruccions de configuració

3.1. Instal·lació de la bateria

  1. Ensure the thermometer is powered off.
  2. Carefully remove the CRS/5 protective boot if it is already installed.
  3. Locate the battery compartment cover on the back of the KM28 thermometer.
  4. Open the cover and insert one 9V IEC 6LF22 alkaline battery, observing the correct polarity (+/-).
  5. Tanqueu bé la tapa del compartiment de la bateria.

3.2. Attaching the Probe

  1. Identify the sub-miniature connector on the PK19M probe cable.
  2. Locate the corresponding input port on the KM28 thermometer.
  3. Gently insert the probe connector into the thermometer's port until it is firmly seated.

3.3. Installing the Protective Boot

Slide the CRS/5 protective boot over the KM28 thermometer unit. Ensure all buttons and the display are accessible and the boot fits snugly to provide maximum protection.

4. Instruccions de funcionament

4.1. Encès / apagat

  • To power on the thermometer, press the On/Off botó.
  • Per apagar-lo, manteniu premut el botó On/Off button until the display turns off. The device also features an auto switch-off function to conserve battery life.

4.2. Mesura de la temperatura

  1. Ensure the probe is securely connected to the thermometer.
  2. Enceneu el dispositiu.
  3. Insert the tip of the PK19M probe into the substance or area where temperature measurement is required. Ensure the probe tip is fully immersed or in firm contact for accurate readings.
  4. Espereu que la lectura a la pantalla s’estabilitzi.

4.3. Switching Temperature Units (°C/°F)

Per canviar entre Celsius (°C) i Fahrenheit (°F), premeu la tecla ° C / ° F button while the thermometer is powered on.

4.4. Temporitzador de compte enrere

The KM28 thermometer includes a countdown timer function. Refer to the full Comark KM28 manual for detailed instructions on setting and using the timer, as specific steps are not provided in this kit overview.

5. Cura i Manteniment

5.1. Neteja

The KM28 thermometer and PK19M probe are water resistant and designed for easy cleaning. To clean:

  • Wipe the thermometer and probe with a damp drap i detergent suau.
  • Do not submerge the thermometer unit in water, despite its water-resistant properties. The probe can be rinsed directly.
  • Ensure all components are thoroughly dried before storage or next use.

5.2. Substitució de la bateria

When the battery indicator appears on the display, replace the 9V battery as described in Section 3.1. Prompt battery replacement ensures continued accuracy and functionality.

5.3. Emmagatzematge

Store the Comark KM28 Thermocouple Kit in a clean, dry place away from extreme temperatures and direct sunlight. Keep the protective boot on the thermometer when not in use to prevent damage.

6. Solució De Problemes

If you encounter issues with your Comark KM28 Thermocouple Kit, refer to the following common problems and solutions:

  • Sense pantalla:
    • Comproveu si la bateria està instal·lada correctament i té prou càrrega. Substituïu-la si cal.
    • Assegureu-vos el On/Off button has been pressed firmly.
  • Lectures inexactes:
    • Verify the probe is securely connected to the thermometer.
    • Ensure the probe tip is properly immersed or in full contact with the substance being measured.
    • Check for any visible damage to the probe cable or tip.
    • Confirm the thermometer is operating within its specified temperature range.
  • Botons que no responen:
    • Remove the protective boot and check if any debris is obstructing the buttons.
    • Proveu de substituir la bateria.

If problems persist, contact Comark customer support for further assistance.

7. Especificacions

Comark KM28 Thermocouple Kit Specifications
Model KM28KIT
Tipus de termòmetre Termoparell tipus K
Measurement Range (°C) -40 °C a 500 °C
Measurement Range (°F) -40 °F a 1000 °F
Instrument Accuracy -30°C to +110°C (-22°F to +230°F): ±1°C/2°F
Full Range: ±3% of reading
Resolució 0.1° up to +190°C / +374°F, then 1° above
Interval de temperatura de funcionament De 0 °C a 50 °C (32 °F a 122 °F)
Tipus de bateria 9V IEC 6LF22 Alkaline
Durada de la bateria Aproximadament 300 hores
Característiques especials Countdown timer, Water resistant, Membrane keypad, Auto switch-off
Connector de sonda Sub-miniature
Dimensions del producte 168 x 1 x 1 inches (Note: This dimension seems to be for the package or a combined item, not the thermometer itself. Refer to manufacturer for precise unit dimensions.)
Pes de l'article 14.4 unces
UPC 095969433419
Diagram of PK19M probe dimensions

Figura 4: Dimensional diagram of the PK19M probe, indicating a total length of 100mm for the metal shaft, with a diameter of 3mm tapering to 1.5mm at the tip.

8. Garantia i Suport

For warranty information, technical support, or service inquiries regarding your Comark KM28 Thermocouple Kit, please contact Comark Instruments directly or visit their official website. Details on specific warranty periods and terms are typically provided with the product packaging or on the manufacturer's weblloc.

Manufacturer: Comark

Documents relacionats - KM28KIT

Preview COMARK-6 Rugged PDA Operating Manual
Comprehensive operating manual for the COMARK-6 Rugged PDA, detailing its features, Windows 10 interface, basic operations, and GPS module functionality for both Windows and Android environments.
Preview Guia d'actualització del programari i del firmware del termòmetre HACCP Comark HT100
Instruccions completes per actualitzar el programari i el firmware del termòmetre HACCP Comark HT100. Apreneu a descarregar, instal·lar actualitzacions i mitigar possibles problemes de dades.
Preview Restart and Factory Reset Guide for Comark WiFi Data Loggers
This guide provides instructions on how to restart and factory reset Comark Diligence WiFi data loggers, including models RF313-TH, RF311-T, RF312-TP, RF312DualPlus, RF312Glycol, RF314-TC, RF314Dual, and RF324 Alert.
Preview KM14 Waterproof Digital Thermometer User Guide and Specifications
Comprehensive guide to the Comark KM14 Waterproof Digital Thermometer, covering operation, calibration, specifications, and product identification. Learn how to use and maintain your digital thermometer.