1. Introducció
This manual provides essential instructions for the safe and effective use of your Fluke 106 Palm-sized Digital Multimeter. The Fluke 106 is a compact, reliable tool designed for basic electrical measurements in various applications. Please read this manual thoroughly before operating the device.
2. Informació de seguretat
Always adhere to safety precautions when using any electrical testing equipment. Failure to do so may result in injury or damage to the multimeter or equipment under test.
- Rated for CAT III 600V: This multimeter is designed for measurements in distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, socket outlets in the fixed installation, and equipment for industrial use and some other equipment, e.g. stationary motors with permanent connection to fixed installation.
- No feu servir el multímetre si sembla que està danyat o si els cables de prova estan danyats.
- Assegureu-vos que s'hagin seleccionat la funció i el rang correctes abans de fer mesures.
- Always connect the common (COM) test lead before connecting the live test lead. Disconnect the live test lead first.
- No apliqueu més del volum nominaltage, as marked on the multimeter, between terminals or between any terminal and earth ground.
- Tingueu precaució amb el voltagper sobre de 30 V CA RMS, 42 V pic o 60 V CC. Aquests voltagsuposen un risc de xoc.
- Substituïu les piles quan aparegui l'indicador de bateria baixa per garantir lectures precises.
3. Què hi ha a la caixa
Upon unpacking your Fluke 106 Digital Multimeter, verify that all items listed below are present and in good condition:
- Multímetre digital Fluke 106
- TL75 Test Leads (one red, one black)
- 2 AAA Batteries (pre-installed or included separately)
- Manual d'usuari (aquest document)

4. Producte acabatview
The Fluke 106 is designed for ease of use with a clear display and intuitive rotary dial. Its compact size makes it convenient for portability.


4.1. Controls i pantalla
- Visualització: Mostra lectures de mesura, unitats i indicadors de funció.
- Interruptor rotatiu: Used to select measurement functions (OFF, V~, V-, mV~, mV-, Ω, Continuity, Capacitance, A~, A-).
- Botó HOLD: Freezes the current reading on the display. Press again to release.
- Terminals d'entrada:
- COM: Terminal comú per a totes les mesures (cable de prova negre).
- VΩ: Entrada per al voltage, resistance, continuity, and capacitance measurements (red test lead).
- 10A FUSED: Input for current measurements up to 10A (red test lead).
5. Configuració
5.1. Instal·lació de la bateria
The Fluke 106 requires two AAA batteries. These are typically included and may be pre-installed. If not, or if replacement is needed:
- Assegureu-vos que el multímetre estigui APAGAT.
- Localitzeu la tapa del compartiment de la bateria a la part posterior del multímetre.
- Feu servir un tornavís per treure el cargol que fixa la tapa.
- Carefully remove the old batteries (if any) and insert two new AAA batteries, observing the correct polarity (+/-).
- Substituïu la tapa del compartiment de la bateria i fixeu-la amb el cargol.
5.2. Connexió dels cables de prova
Connecteu sempre els cables de prova correctament per obtenir mesures precises i segures.
- Introduïu el cable de prova negre al COM (common) terminal.
- Per al voltage, resistance, continuity, and capacitance measurements, insert the red test lead into the VΩ terminal.
- For current measurements (up to 10A), insert the red test lead into the 10A FUSIBLE terminal.
6. Instruccions de funcionament
Before taking any measurement, ensure the test leads are correctly connected and the rotary switch is set to the desired function.
6.1. Mesura de vol AC/DCtage (V~ / V-)
- Configureu el commutador rotatiu a V~ per a AC voltage o V- per a DC voltage.
- Connect the black test lead to the COM terminal and the red test lead to the VΩ terminal.
- Toqueu les sondes de prova als punts on voleu mesurar el volumtage. The reading will appear on the display.
6.2. Mesura de la resistència (Ω)
- Configureu el commutador rotatiu a Ω.
- Connect the black test lead to the COM terminal and the red test lead to the VΩ terminal.
- Assegureu-vos que el circuit o component estigui desenergitzat abans de mesurar la resistència.
- Touch the test probes across the component or circuit. The resistance value will be displayed.
6.3. Prova de continuïtat ())))
- Poseu el commutador rotatiu a la Ω position. The multimeter will automatically detect continuity.
- Connect the black test lead to the COM terminal and the red test lead to the VΩ terminal.
- Assegureu-vos que el circuit o component estigui desenergitzat.
- Touch the test probes across the points to be tested. If continuity exists (low resistance), the multimeter will emit an audible beep.
6.4. Measuring Capacitance (--| |--)
- Poseu el commutador rotatiu a la --| |-- posició.
- Connect the black test lead to the COM terminal and the red test lead to the VΩ terminal.
- Ensure the capacitor is discharged before testing.
- Touch the test probes across the capacitor terminals. The capacitance value will be displayed.
6.5. Measuring AC/DC Current (A~ / A-)
- IMPORTANT: For current measurements, the multimeter must be connected in series with the circuit.
- Configureu el commutador rotatiu a A~ per a corrent altern o A- per a corrent continu.
- Connecteu el cable de prova negre al terminal COM i el cable de prova vermell al terminal 10A FUSIBLE terminal.
- Open the circuit where you want to measure current and insert the multimeter in series.
- The current reading will appear on the display.
6.6. Retenció de dades
Premeu el botó MANTENIM button to freeze the current reading on the display. This is useful for taking readings in hard-to-see locations. Press the MANTENIM de nou per alliberar la lectura i tornar a la mesura en directe.
7. Manteniment
7.1. Neteja
Per netejar el multímetre, netegeu la carcassa amb aiguaamp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the multimeter is completely dry before use.
7.2. Substitució de la bateria
When the low battery indicator appears on the display, replace the batteries as described in Section 5.1. Using the multimeter with low batteries may result in inaccurate readings.
8. Solució De Problemes
If your Fluke 106 multimeter is not functioning as expected, consider the following common issues:
- Sense pantalla / Pantalla tènue: Comproveu la càrrega de la bateria. Canvieu les piles si cal.
- Lectures incorrectes:
- Ensure the correct function is selected on the rotary switch.
- Verify test leads are securely connected to the correct terminals.
- Comproveu si hi ha cables de prova danyats.
- Ensure the circuit is de-energized for resistance/continuity/capacitance tests.
- Sense bip de continuïtat: Ensure the rotary switch is set to the continuity function (part of Ω range) and the circuit has low resistance.
- Overload Indication (OL): The measured value exceeds the selected range. Switch to a higher range if available, or verify the circuit is within the multimeter's capabilities.
If problems persist, contact Fluke customer support or an authorized service center.
9. Especificacions
| Característica | Especificació |
|---|---|
| Model | Fluke 106 |
| Funcions de mesura | Voltage (AC/DC), Resistance, Continuity, Capacitance, Current (AC/DC) |
| Max Current Measurement | 10 A |
| Classificació de seguretat | CAT III 600V |
| Retenció de dades | Sí |
| Font d'alimentació | 2 piles AAA (incloses) |
| Dimensions del producte | 5.59 x 2.72 x 1.1 polzades (14.2 x 6.9 x 2.8 cm) |
| Pes de l'article | 7.05 unces (0.2 kg) |
| País d'origen | Xina |
10. Garantia i Suport
Fluke products are known for their quality and reliability. For warranty information and technical support, please refer to the official Fluke website or contact an authorized Fluke distributor. Ensure your product is sourced from an authorized distributor to guarantee authenticity and valid warranty coverage.

Per obtenir més ajuda, visiteu el Fluke Store or contact Fluke customer service.