1. Introducció

The Keithley Model 2000 is a 6½-digit bench digital multimeter designed for high-performance measurement applications. It utilizes advanced A/D converter technology to provide fast, accurate, and stable measurements. This manual provides essential information for the safe and effective operation of your Keithley 2000 multimeter.

2. Informació de seguretat

ADVERTIMENT:

3. Producte acabatview

3.1 Tauler frontal

The front panel of the Keithley 2000 features the display, function buttons, input terminals, and power switch.

Davant view of the Keithley 2000 Digital Bench Multimeter

Imatge: Frontal view of the Keithley 2000 Digital Bench Multimeter, showing the display, control buttons, and input terminals.

3.2 Panell posterior

The rear panel provides connections for power, communication interfaces, and fuse access.

posterior view of the Keithley 2000 Digital Bench Multimeter

Imatge: Part posterior view of the Keithley 2000 Digital Bench Multimeter, showing power input, GPIB, RS-232, and trigger link ports.

3.3 Optional Scanner Cards

The Model 2000 supports optional scanner cards for multiplexing up to 20 different input signals, enabling multipoint measurement applications.

Optional scanner card for Keithley 2000 Multimeter

Image: An optional scanner card, which can be installed in the Keithley 2000 to expand its input capabilities for multipoint measurements.

4. Configuració

4.1 Connexió d'alimentació

  1. Ensure the power switch on the front panel is in the OFF position.
  2. Connect the supplied AC power cord to the power input receptacle on the rear panel.
  3. Connecteu l'altre extrem del cable d'alimentació a una presa de corrent de CA amb connexió a terra.

4.2 Engegada inicial

  1. Press the power switch on the front panel to the ON position.
  2. The instrument will perform a self-test and display its firmware version.
  3. Once the self-test is complete, the multimeter will be ready for operation.

5. Instruccions de funcionament

The Keithley 2000 offers 13 built-in measurement functions. This section covers basic operation for common measurements.

En angle view of the Keithley 2000 Multimeter showing the display

Imatge: Anglesa view of the Keithley 2000 Digital Bench Multimeter, highlighting the clear digital display showing a measurement.

5.1 DC Voltage Mesurament (DCV)

  1. Premeu el botó DCV botó de funció.
  2. Connecteu els cables de prova al HI (vermell) i LO (black) input terminals on the front panel.
  3. Connecteu els cables de prova al component o circuit que s'ha de mesurar.
  4. El vol DCtage reading will appear on the display.

5.2 Mesura de resistència (Ω)

  1. Premeu el botó Ω botó de funció.
  2. Connecteu els cables de prova al HI (vermell) i LO (black) input terminals.
  3. Ensure the circuit or component is de-energized before connecting the leads.
  4. Connect the test leads across the resistor or circuit to be measured.
  5. The resistance reading will appear on the display.

5.3 Current Measurement (DCI/ACI)

  1. Premeu el botó DCI or ACI function button depending on the current type.
  2. Connect the test leads to the dedicated 3A, 250V AMPS input terminals on the front panel.
  3. Ensure the circuit is de-energized before connecting the leads.
  4. Connecteu el multímetre en sèrie amb el circuit on es vol mesurar el corrent.
  5. Apply power to the circuit. The current reading will appear on the display.

For other functions like AC Voltage (ACV), Frequency (FREQ), Temperature (TEMP), and advanced settings, refer to the detailed programming manual available on the Keithley weblloc.

6. Manteniment

6.1 Neteja

To clean the instrument, use a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners or solvents. Ensure the instrument is powered off and disconnected from all power sources before cleaning.

6.2 Canvi de fusibles

If the instrument does not power on, the fuse may need replacement. The fuse holder is located on the rear panel. Always replace the fuse with one of the same type and rating as specified on the instrument (e.g., 250mA T, 100/120 VAC or 125mA T, 220/240 VAC).

  1. Desconnecteu el cable d'alimentació de l'instrument.
  2. Open the fuse holder cover.
  3. Remove the old fuse and insert a new fuse of the correct rating.
  4. Close the fuse holder cover securely.

7. Solució De Problemes

ProblemaCausa possibleSolució
L'instrument no s'encén.No AC power; Blown fuse.Check power cord connection; Replace fuse (refer to Section 6.2).
Lectures incorrectes o inestables.Improper test lead connection; Measurement range too high/low; External interference.Ensure secure connections; Use AUTO RANGE or manually select appropriate range; Shield test leads or move away from noise sources.
Display shows "OVERLOAD" or "OL".Input signal exceeds selected range.Select a higher measurement range or check if the input signal is within the instrument's maximum ratings.

8. Especificacions

ParàmetreValor
Tipus de mesuraMultímetre
Dígits
DC Voltage Rang100nV to 1kV
DC Resistance Range100µΩ to 100MΩ
Taxa de lectura2000 readings/second (at 4½ digits)
Funcions incorporades13
Interfícies de comunicacióGPIB, RS-232
Pes de l'article4.42 quilos
Dimensions del paquet48.51 x 32.51 x 25.15 cm

9. Garantia i Suport

For warranty information and technical support, please refer to the documentation included with your product or visit the official Keithley website. Keithley provides comprehensive resources, including detailed manuals, software downloads, and contact information for customer service and technical assistance.

You can typically find support resources at www.tek.com/keithley.

Documents relacionats - 2000

Preview Keithley 2000/2015/2016/2010 LED Display Replacement Instructions
Step-by-step guide for replacing the VFD display with an LED display on Keithley 2000, 2015, 2016, and 2010 multimeters. Includes disassembly, component replacement, front bezel modification, and reassembly.
Preview Targeta d'escàner Keithley Model 2000-SCAN: Manual de referència
Manual complet de referència i instruccions per a la targeta d'escàner Keithley Model 2000-SCAN, que detalla les seves característiques, instal·lació, funcionament, servei i especificacions per al seu ús amb els multímetres Keithley Model 2000, 2001 i 2002.
Preview Manual d'instruccions de l'electròmetre/multímetre Keithley Model 619
Manual d'instruccions complet per a l'electròmetre/multímetre Keithley Model 619, que detalla les especificacions, el funcionament, el manteniment, la teoria de funcionament i la resolució de problemes d'aquest instrument de prova electrònic de precisió.
Preview Keithley Test & Measurement Product Catalog: Digital Multimeters and Systems
Explore the extensive capabilities of Keithley's Test & Measurement solutions. This catalog showcases a wide array of high-precision digital multimeters, versatile data acquisition systems, and robust switch systems designed for demanding applications across various industries, including models like the 2110, 2100, 2000 series, 3700A, and Integra series.
Preview Keithley Model 2461-SYS SourceMeter Instrument Firmware Release Notes v1.7.16
Detailed firmware release notes for the Keithley Model 2461-SYS SourceMeter Instrument, covering version 1.7.16 and previous releases, including overview, enhancements, critical fixes, noncritical fixes, and known issues.
Preview Manual d'instruccions de l'electròmetre/multímetre Keithley Model 619
Comprehensive instruction manual for the Keithley Model 619 Electrometer/Multimeter, detailing its specifications, operation, features, and maintenance. Covers electrical measurements for volts, amps i ohms.