Delta Dore Tybox 417

Delta Dore Tybox 417 Thermostat for Heat Pumps User Manual

1. Introducció

This manual provides essential information for the safe and efficient use of your Delta Dore Tybox 417 thermostat, specifically designed for heat pump applications. Please read these instructions carefully before installation and operation to ensure proper functionality and to prevent damage to the device or your heating system.

2. Producte acabatview

The Delta Dore Tybox 417 is a programmable thermostat designed to optimize the control of heat pump systems, contributing to energy efficiency and comfort. It features a clear digital display and intuitive controls.

Davant view of the Delta Dore Tybox 417 thermostat, showing the digital display with time and current temperature, and control buttons on the right side.

Figura 1: Davant view of the Delta Dore Tybox 417 thermostat, showing the digital display with time (10:57) and current temperature (19.7°C), along with four control buttons on the right side and a rotary knob at the bottom. The display also indicates weekly programming (numbers 1-7 on the left) and an active heating icon.

En angle view of the Delta Dore Tybox 417 thermostat, highlighting its compact design and side profile.

Figura 2: En angle view of the Delta Dore Tybox 417 thermostat, showcasing its compact design and the depth of the unit.

Davant view of the Delta Dore Tybox 417 thermostat with the digital display off, illustrating its sleek appearance when inactive.

Figura 3: Davant view of the Delta Dore Tybox 417 thermostat with the digital display inactive, demonstrating its clean and unobtrusive design.

Components clau:

  • Pantalla digital: Shows time, current temperature, operating mode, and programming indicators.
  • Botons de control: Located on the right side, used for menu navigation and setting adjustments.
  • Pom giratori: Located at the bottom, primarily used for temperature adjustment and confirming selections.

3. Instruccions de seguretat

Si us plau, observeu les precaucions de seguretat següents:

  • Seguretat elèctrica: Installation and wiring must be performed by a qualified electrician in accordance with local electrical codes and regulations. The device operates at 230 Volts.
  • Desconnexió d'alimentació: Always disconnect power to the heating system at the main circuit breaker before performing any installation, wiring, or maintenance.
  • Ús previst: Use this thermostat only for its intended purpose of controlling heat pump systems.
  • Condicions ambientals: Do not expose the device to extreme temperatures, humidity, or direct water contact.

4. Configuració i instal·lació

Installation of the Delta Dore Tybox 417 requires electrical knowledge. It is strongly recommended that a professional electrician performs the installation.

4.1 Ubicació de muntatge

Choose an interior wall location, approximately 1.5 meters (5 feet) from the floor, away from direct sunlight, drafts, and heat sources (e.g., lamps, fireplaces, refrigerators) that could affect temperature readings.

4.2 Cablejat

  1. Desconnecteu l'alimentació: Turn off the main power supply to your heating system at the circuit breaker.
  2. Terminals de cablejat d'accés: Obriu amb cura el termòstat casing to access the wiring terminals. Refer to the wiring diagram provided with the product packaging for specific connections.
  3. Connecteu els cables: Connect the 230V power supply and the heat pump control wires to the appropriate terminals. Ensure all connections are secure.
  4. Tanca Casing: Securely close the thermostat casing.

4.3 Engegada inicial

Once wiring is complete and the casing is closed, restore power to the heating system. The thermostat display should illuminate, indicating it is powered on. Follow any on-screen prompts for initial setup, such as setting the current time and date.

5. Instruccions de funcionament

The Tybox 417 offers various modes and settings for precise temperature control.

5.1 Mostra informació

  • Hora: Current time (e.g., 10:57).
  • Temperatura: Current ambient temperature (e.g., 19.7°C).
  • Mode de funcionament: Icons may indicate heating active (up arrow), frost protection, or other modes.
  • Program Indicators: Numbers 1-7 on the left side typically represent days of the week for programming.

5.2 Ajust de la temperatura

To manually adjust the desired temperature, rotate the large knob at the bottom of the thermostat. The display will show the new setpoint. The system will then work to achieve and maintain this temperature.

5.3 Selecció del mode

Use the buttons on the right side to navigate through different operating modes. Common modes include:

  • Auto/Program Mode: Follows the pre-set weekly schedule.
  • Mode manual: Manté una temperatura constant configurada per l'usuari, anul·lant el programa.
  • Mode de protecció contra gelades: Maintains a minimum temperature (e.g., 7°C) to prevent pipes from freezing.

Consult the detailed instructions in the product packaging for specific button functions and mode configurations.

5.4 Calendari de programació

The Tybox 417 allows for weekly programming to set different temperatures at various times of the day for each day of the week. Access the programming menu using the control buttons and follow the on-screen prompts to:

  • Set desired temperatures for comfort and economy periods.
  • Define time slots for these temperatures.
  • Copy programs between days.

6. Manteniment

The Delta Dore Tybox 417 requires minimal maintenance.

6.1 Neteja

To clean the thermostat, gently wipe the surface with a soft, dry, or slightly damp cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the casing o pantalla.

6.2 Battery Replacement (if applicable)

This model is primarily powered by 230V mains electricity. If your specific unit includes a backup battery for memory retention (not for primary operation), consult the product packaging for instructions on how to replace it. Typically, a low battery indicator will appear on the display when replacement is needed.

7. Solució De Problemes

If you encounter issues with your Tybox 417, try the following steps:

ProblemaCausa possibleSolució
La pantalla està en blancSense font d'alimentacióCheck the circuit breaker for your heating system. Ensure the thermostat is correctly wired.
Lectura de temperatura incorrectaThermostat location affected by external factorsAssegureu-vos que el termòstat no estigui exposat a la llum solar directa, corrents d'aire ni fonts de calor.
Heat pump not respondingIncorrect mode, wiring issue, or heat pump faultVerify the thermostat is in the correct operating mode (e.g., Auto or Manual with a high setpoint). Check wiring connections. If the issue persists, consult a professional.
La programació no funcionaThermostat not in Auto/Program mode, or incorrect settingsEnsure the thermostat is set to Auto/Program mode. Review your programmed schedule for accuracy.

If these steps do not resolve the issue, please contact a qualified technician or Delta Dore customer support.

8. Especificacions

Key technical specifications for the Delta Dore Tybox 417 thermostat:

  • Marca: Delta Dore
  • Model: Tybox
  • Voltage: 230 Volts
  • Dimensions (paquet): 14 x 8.6 x 4.2 cm
  • Pes de l'article: 220 grams

9. Garantia i Suport

For information regarding the warranty period and terms for your Delta Dore Tybox 417, please refer to the warranty card included with your product packaging or your purchase documentation. For technical support, spare parts, or service inquiries, please contact Delta Dore customer service directly or visit their official weblloc.

Documents relacionats - Tybox 417

Preview Notice d'utilisation Delta Dore Tybox Control
Guide complet pour le thermostat connecté Delta Dore Tybox Control. Découvrez l'installation, la configuration, les modes de fonctionnement, les réglages et l'utilisation avec la box Tydom.
Preview Sistema de termòstat sense fil Delta Dore Tybox 5300: guia d'instal·lació i usuari
Guia completa per a la instal·lació, configuració i ús del sistema de termòstat sense fil Delta Dore Tybox 5300, que inclou especificacions tècniques i resolució de problemes.
Preview Delta Dore Tybox 5701 FP/5702 FP i RF 6700 FP: Manual d'instal·lació i d'usuari
Guia completa per a la instal·lació i l'ús dels termostats Delta Dore Tybox 5701 FP, Tybox 5702 FP i el receptor RF 6700 FP, que cobreix la configuració, el funcionament i la resolució de problemes.
Preview Guia d'instal·lació ràpida del paquet connectat Delta Dore Tybox 5100
Guia HTML concisa i optimitzada per a SEO per instal·lar el Delta Dore Tybox 5100 Connected Pack, que inclou el termòstat i la configuració de Tydom Home. Apreneu l'activació pas a pas.
Preview Guia d'instal·lació i usuari del termòstat programable Delta Dore Tybox 1117
Guia completa per al termòstat programable Delta Dore Tybox 1117, que cobreix la instal·lació, la configuració, la programació i l'ús de sistemes de calefacció d'aigua calenta.
Preview Delta Dore TYBOX 1117 Programmable Thermostat Installation and User Guide
Comprehensive guide for the Delta Dore TYBOX 1117 programmable thermostat, covering installation, configuration, programming, and usage. Learn how to set up and optimize your heating control for comfort and energy savings.