GREISINGER GPHU 014 MP/BNC

Logotip de GREISINGER

Manual d'instruccions del convertidor de mesura de pH Greisinger GPHU 014 MP/BNC

Model: GPHU 014 MP/BNC

1. Introducció

This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.

The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.

2. Informació de seguretat

  • Always operate the device within its specified environmental conditions.
  • No exposeu el dispositiu a temperatures extremes, llum solar directa ni humitat elevada.
  • Eviteu deixar caure o sotmetre el dispositiu a forts impactes.
  • Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
  • No intenteu obrir ni reparar el dispositiu vosaltres mateixos. Encarregueu totes les tasques de manteniment a personal qualificat.
  • Use only compatible pH electrodes and accessories with this converter.
  • Dispose of the device and any associated components in accordance with local environmental regulations.

3. Contingut del paquet

Si us plau, comproveu el contingut del paquet en rebre'l. Si falta algun article o està malmès, poseu-vos en contacte amb el vostre proveïdor immediatament.

  • Greisinger GPHU 014 MP/BNC pH Measurement Converter
  • Manual d'instruccions (aquest document)
  • Mounting accessories (if applicable, check packaging)

Note: A pH electrode is not included with this converter and must be purchased separately.

4. Producte acabatview

The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.

Greisinger GPHU 014 MP/BNC pH Measurement Converter front view

Figura 1: Davant view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.

Greisinger GPHU 014 MP/BNC pH Measurement Converter side view

Figura 2: lateral view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".

Components clau:

  • Pantalla digital: Shows pH value, temperature, and status indicators.
  • Botó SET (1): S'utilitza per introduir i confirmar la configuració.
  • Down Button (2): Used to navigate menus and decrease values.
  • Up Button (3): Used to navigate menus and increase values.
  • BNC Connector: For connecting a compatible pH electrode.
  • Entrada d'alimentació: (Location not visible in images, refer to device for exact position)

5. Configuració

5.1. Muntatge

The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.

5.2. Connecting the pH Electrode

  1. Ensure the converter is powered off.
  2. Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
  3. Assegureu-vos que la connexió sigui segura però no l'estrengueu massa.

5.3. Connexió d'alimentació

Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.

5.4. Calibració inicial

Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.

  1. Enceneu el dispositiu.
  2. Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
  3. Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
  4. Rinse the electrode thoroughly with distilled water between buffer solutions.
  5. Confirm calibration settings.

6. Funcionament

6.1. Prendre una mesura

  1. Ensure the pH electrode is properly connected and calibrated.
  2. Immerse the pH electrode into the sampla solució, assegurant-se que la bombeta sensora i la junció de referència estiguin completament submergides.
  3. Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
  4. Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.

6.2. Navegació del menú

The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.

  • SET (1): Enter/Exit menu, confirm selection.
  • ▼ (2): Scroll down, decrease value.
  • ▲ (3): Scroll up, increase value.

Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.

7. Manteniment

7.1. Cleaning the Converter

Wipe the exterior of the converter with a soft, damp drap. No utilitzeu productes de neteja abrasius ni dissolvents. Assegureu-vos que no entri líquid al dispositiu.

7.2. Manteniment d'elèctrodes de pH

Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:

  • Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
  • Rinse the electrode with distilled or deionized water after each measurement.
  • Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
  • Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.

7.3. Emmagatzematge

When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.

8. Solució De Problemes

Problema Causa possible Solució
No display/Device not powering on No power, faulty power supply, incorrect connection. Comproveu el cable d'alimentació i la font. Assegureu-vos que el volum sigui correcte.tage.
Unstable or inaccurate pH readings Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings.
Missatge d'"error" a la pantalla Electrode fault, out of range measurement, internal device error. Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent.
Temps de resposta lent Aged or dirty electrode, low sampla temperatura. Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode.

If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.

9. Especificacions

Característica Detall
Fabricant GREISINGER
Número de model de l'article 602331
Dimensions del producte (L x A x A) 5.5 x 8.2 x 8 cm; 9.07 grams
ASIN B00ICKLET6
Quantitat d'articles 1
Battery(ies) included No
Battery(ies) required No
Date first available on Amazon.com.be 12 d'agost de 2022
Discontinued by manufacturer No
Disponibilitat de peces de recanvi Informació no disponible sobre peces de recanvi

10. Garantia i Suport

Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger weblloc.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger weblloc.

Documents relacionats - GPHU 014 MP/BNC

Preview Manual d'instruccions de GREISINGER GE xxx: Elèctrodes de pH
Manual d'instruccions complet per als elèctrodes de pH de la sèrie xxx de GREISINGER GE, que cobreix la seguretat, els conceptes bàsics, la mesura, el calibratge, el manteniment, la selecció i les especificacions. Inclou una guia detallada per a una mesura precisa del pH.
Preview GREISINGER EBUW 232 EASYBUS Protocol Converter Operating Manual
Operating manual for the GREISINGER EBUW 232 EASYBUS protocol converter, detailing its specifications, general information, and safety requirements.
Preview Manual GREISINGER GIA 20 EB / PK: Connexió i funcionament
This manual provides comprehensive instructions for the GREISINGER GIA 20 EB / PK microprocessor-controlled displaying, monitoring, and controlling device. It covers safety regulations, electrical connections for various input signals and output types, device configuration using software, switchpoint and alarm settings, offset/slope adjustment, serial interface, error codes, specifications, and disposal notes.
Preview Manual d'instruccions del termòmetre de precisió GREISINGER GMH 3710
This operating manual provides detailed instructions for the GREISINGER GMH 3710 precision thermometer. It covers intended use, safety precautions, product specifications, handling, configuration, output options, input adjustments, probe connections, basic temperature measurement principles, fault messages, and disposal guidelines for Pt100 temperature sensors.
Preview Manòmetres i baròmetres Greisinger GDH sèrie 200: informació tècnicaview
Discover the Greisinger GDH 200 series handheld pressure measurement instruments. This document details the GDH 200-07 fine manometer, GDH 200-13 manometer, and GDH 200-14 vacuum/barometer, highlighting their specifications and features for professional use.
Preview Manual d'instruccions del mesurador d'humitat GREISINGER GMH 38-LW1 / -LW2 Apèndix
Operating manual appendix for the GREISINGER GMH 38-LW1 / -LW2 moisture measuring set for agricultural applications. Covers intended use, safety, product description, handling, principles of measurement, and specifications for wood chips, grain, hay, and straw.