Introducció
This manual provides essential information for the proper installation, operation, and maintenance of your Continental Refrigerator DL2R-SS-PT-HD Designer Line Refrigerator. This is a pass-thru, two-section, self-contained refrigeration unit designed for commercial use. Please read this manual thoroughly before operating the appliance to ensure safe and efficient performance.
Instruccions de seguretat
Seguiu sempre les precaucions de seguretat bàsiques quan utilitzeu aparells elèctrics per reduir el risc d'incendi, descàrrega elèctrica i lesions a les persones.
- Assegureu-vos que la nevera estigui connectada a una presa de corrent amb connexió a terra.
- No feu servir l'aparell amb un cable o un endoll danyats.
- Keep ventilation openings clear of obstructions. Adequate airflow is crucial for efficient operation.
- No emmagatzemeu substàncies explosives com ara llaunes d'aerosol amb un propulsor inflamable en aquest aparell.
- Desendolleu la nevera abans de netejar-la o fer-ne cap manteniment.
- Do not allow children to play with or inside the refrigerator.
- Handle the unit with care during movement to prevent damage to refrigeration lines.
Configuració
Desembalatge
Carefully remove all packaging materials, including tape and protective film. Inspect the unit for any shipping damage. Report any damage to the carrier immediately.
Col·locació
Place the refrigerator on a strong, level surface capable of supporting its weight when fully loaded. Ensure there is adequate clearance around the unit for proper ventilation, especially at the top and rear where the condenser is located. Avoid direct sunlight or heat sources.
Connexió elèctrica
Connect the refrigerator to a dedicated electrical circuit with the correct voltage i amperage as specified on the unit's data plate. Do not use extension cords or adapter plugs.
Neteja inicial
Before first use, clean the interior and exterior of the refrigerator with a mild soap and water solution. Rinse thoroughly and dry completely.
Inici inicial
After cleaning and placement, plug in the unit. Allow the refrigerator to operate for at least 2-4 hours empty to reach its set temperature before loading with products.

This image displays the Continental Refrigerator DL2R-SS-PT-HD, a two-section pass-thru unit, with all four half-height stainless steel doors open. The interior shows multiple adjustable shelves, highlighting its storage capacity and pass-thru design.
Instruccions de funcionament
Control de temperatura
The refrigerator is equipped with an exterior digital thermometer for easy monitoring and adjustment of the internal temperature. Refer to the specific controls for setting the desired temperature. Ensure the temperature is maintained within safe food storage guidelines.
Càrrega i Descàrrega
Utilize the pass-thru design by loading from one side and unloading from the other to maintain efficient workflow. Do not overload shelves, as this can restrict airflow and reduce cooling efficiency. Distribute items evenly.
Ús de la porta
Ensure all half-height stainless steel doors close completely after each use to maintain internal temperature and energy efficiency. Check door gaskets regularly for proper seal.
Manteniment
Neteja regular
- Interior: Clean the interior regularly with a mild, non-abrasive cleaner and warm water. Rinse and dry thoroughly to prevent odors and bacterial growth.
- Exterior: Wipe down the stainless steel exterior with a soft cloth and a stainless steel cleaner to maintain its finish.
- Serpentina del condensador: The condenser coil should be cleaned periodically (e.g., monthly or quarterly, depending on environment) to ensure optimal performance. Unplug the unit, locate the coil (usually at the top or rear), and use a brush or vacuum cleaner to remove dust and debris.
Door Gasket Inspection
Regularly inspect door gaskets for cracks, tears, or signs of wear. Damaged gaskets compromise the seal, leading to energy loss and inefficient cooling. Replace worn gaskets promptly.
Paella d'escorregut
Periodically check and clean the drain pan to prevent blockages and overflow. This is typically located near the compressor.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La nevera no es refreda | Power supply issue, dirty condenser coil, door left open, thermostat setting too high. | Check power connection and circuit breaker. Clean condenser coil. Ensure doors are closed. Adjust thermostat. |
| Soroll excessiu | Unitat no anivellada, obstrucció del ventilador, components solts. | Level the unit using adjustable legs. Check for obstructions around fan blades. Contact service if noise persists. |
| Aigua al terra/interior | Clogged drain line, damaged door gasket, high humidity. | Clear drain line. Inspect and replace door gaskets. Ensure proper ventilation. |
| La pantalla digital no funciona | Power issue, display malfunction. | Check power. If power is present, contact qualified service personnel. |
For issues not listed or if solutions do not resolve the problem, contact a qualified service technician.
Especificacions
- Model: DL2R-SS-PT-HD
- Tipus: Designer Line Refrigerator, Pass-Thru, Two-Section
- Refrigeració: Autocontingut
- Acabat exterior: Acer inoxidable
- Acabat interior: Acer inoxidable
- Portes: Half-Height Stainless Steel Doors (2 sections, 4 doors total)
- HP del compressor: 1/3 CV
- Profunditat: Standard Depth Cabinet
- Cames: 6" Stainless Steel Legs
- Termòmetre: Exterior Digital Thermometer
- Fabricant: Continental
Garantia i Suport
For specific warranty terms and conditions, please refer to the warranty card included with your purchase or contact Continental directly. Warranty coverage typically varies by component and region.
For technical support, service inquiries, or to order replacement parts, please contact your authorized Continental service provider or the dealer from whom the unit was purchased. Have your model number (DL2R-SS-PT-HD) and serial number ready when contacting support.