Introducció

This manual provides essential information for the proper installation, operation, and maintenance of the Watts Series 335 ASME rated Boiler Pressure Relief Valve. This valve is designed for hydronic systems, specifically for boilers up to 510,000 BTU at a 30 PSI (2.11 bar) set point. Its compact, all-bronze construction makes it suitable for various OEM boiler applications.

Watts 30 PSI Pressure Relief Valve, front view

Figura 1: Frontal view of the Watts 30 PSI Pressure Relief Valve, showing the bronze body and the pressure relief lever.

Informació de seguretat

Always follow local codes and regulations during installation and maintenance. Ensure the system is depressurized and cooled before attempting any work on the valve. Wear appropriate personal protective equipment (PPE).

Configuració i instal·lació

The Watts 0342691 Pressure Relief Valve is designed for straightforward installation. It features a 3/4-inch female threaded inlet and a 3/4-inch FNPT outlet.

  1. Preparació: Ensure the boiler system is completely shut down, depressurized, and cooled. Drain any water from the system if necessary.
  2. Remove Old Valve (if applicable): Carefully unthread the existing pressure relief valve from the boiler.
  3. Aplicar segellador de rosques: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male threads of the new Watts valve.
  4. Instal·lar una vàlvula nova: Thread the new valve into the boiler's pressure relief valve port. Tighten securely with a wrench, ensuring not to overtighten.
  5. Connecteu la canonada de descàrrega: Attach appropriate discharge piping to the valve's outlet. This piping must be sized correctly and routed to a safe discharge point, preventing scalding or property damage.
  6. System Re-pressurization: Slowly re-pressurize the boiler system and check for any leaks around the newly installed valve and connections.
Watts 30 PSI Pressure Relief Valve, side view

Figura 2: lateral view of the Watts 30 PSI Pressure Relief Valve, showing the compact design and connection points.

Principis de funcionament

The Watts 0342691 is an automatic pressure relief valve designed to protect hydronic heating systems from over-pressurization. It is factory-set to open at 30 PSI (Pounds per Square Inch). When the system pressure exceeds this set point, the valve will automatically open, discharging water to relieve the excess pressure and prevent damage to the boiler or system components. Once the pressure drops below the set point, the valve will automatically close.

The valve also features a manual test lever. This lever allows for periodic manual testing of the valve's operation. When the lever is lifted, the valve will open, discharging water. It is important to exercise caution when using the test lever, as hot water may be discharged.

Manteniment

Regular maintenance ensures the longevity and proper function of your pressure relief valve.

Resolució de problemes

ProblemaCausa possibleSolució
Valve constantly dripping or leaking
  • Pressió del sistema massa alta
  • Sediment or debris under the seat
  • Worn or damaged internal components
  • Improper installation (e.g., insufficient thread sealant)
  • Check system pressure; ensure it is below 30 PSI.
  • Briefly lift the test lever to flush out debris.
  • If leaking persists, the valve may need replacement.
  • Re-install with proper thread sealant if leak is from threads.
Valve does not open when pressure is high
  • Valve seized due to corrosion or lack of use
  • Incorrect valve installed (wrong pressure setting)
  • Attempt to operate the manual test lever.
  • If it remains seized, the valve must be replaced immediately to prevent system damage.
  • Verify the valve's pressure rating matches system requirements.

Especificacions

Watts 30 PSI Pressure Relief Valve with dimensions shown against a hand

Figure 3: The Watts 30 PSI Pressure Relief Valve demonstrating its compact size, approximately 2.9 inches (7 cm) in height.

AtributValor
Número de modelWATTS - 118946
MaterialBronze
Mida de la connexió d'entrada3/4 polzades
Tipus de connexió d'entradaFemale Threaded
Mida de connexió de presa3/4 polzades
Tipus de connexió de presaFNPT
Pressió màxima de funcionament30 PSI (2.11 bar)
Valoració BTUUp to 510,000 BTU
Nombre de Ports2
Dimensions (L x A x A)3 x 2.3 x 1.8 polzades
Pes0.01 ounces (Note: This seems unusually low, likely a data entry error in source. Actual weight for such a valve would be higher.)
Especificació MetASME Section IV

Informació de la garantia

Specific warranty details for this product are not provided in this manual. Please refer to the manufacturer's official website or contact Watts customer service for current warranty terms and conditions.

Suport i Contacte

For technical assistance, replacement parts, or further information, please contact Watts customer support or visit their official weblloc.

Watts Oficial Weblloc: www.watts.com

Watts Store on Amazon: Visit the Watts Store

Documents relacionats - WATTS - 118946

Preview Vàlvula reductora de pressió Watts amb funció de control hidràulic - Sèrie d'acer inoxidable
Tècnic acabatview de la vàlvula combinada de reducció de pressió i retenció Watts ACV, que detalla el seu funcionament, les pautes d'instal·lació i una llista de models de vàlvules de control relacionades.
Preview Vàlvula reductora de pressió Watts W-M115 ACV: especificacions i guia d'instal·lació
Guia completa que detalla les especificacions, dimensions, cabals, principis de funcionament, instal·lació i procediments d'arrencada de la vàlvula reductora de pressió Watts W-M115 ACV. Informació essencial per a aplicacions industrials i comercials.
Preview Guia d'instal·lació del kit de connexió de modernització del sensor d'inundació Watts BMS
Aquesta guia proporciona instruccions d'instal·lació detallades per al kit de connexió de modernització del sensor d'inundació Watts BMS (model IS-RFK-FS-ReliefValve-BMS). Cobreix els components del kit, els requisits, la preparació, els passos d'instal·lació, els diagrames de cablejat i la informació de garantia per a la monitorització de les línies de descàrrega de la vàlvula de seguretat.
Preview Especificacions Tècniques Sèries Watts SL100XL, L100XL, LL100XL, LLL100XL
Especificacions tècniques completes per a les soupapes de descàrrega de la temperatura i la pressió a l'allongada Watts sèries SL100XL, L100XL, LL100XL i LLL100XL. Detalls sobre les característiques, dimensions, instal·lació i seguretat per a l'aigua.
Preview Manual d'instal·lació, funcionament i manteniment de les vàlvules de control reductores de pressió Watts LFM115-74/LFM6115-74
Guia completa per a la instal·lació, el funcionament, el manteniment i la resolució de problemes de les vàlvules de control reductores de pressió Watts LFM115-74 i LFM6115-74 amb bypass de baix cabal. Inclou instruccions detallades, diagrames i programes de manteniment.
Preview Guia d'instal·lació i manteniment de la vàlvula reductora de pressió d'aigua Watts sèrie LFN45B
Guia completa per a la instal·lació, el manteniment i la resolució de problemes de la vàlvula reductora de pressió d'aigua de la sèrie Watts LFN45B. Inclou avisos de seguretat, procediments d'ajust i informació sobre la garantia.