Introducció
This manual provides detailed instructions for the safe and efficient operation of your TekPower TP50SW 50 Amp 13.8V Analog DC Power Supply. The TP50SW is designed to provide stable DC power for various applications, including Ham and CB radio equipment. It features a highly stable, fused, analog switching power supply with both fixed 13.8V and adjustable 9-15V DC output, capable of delivering up to 50A maximum current. Please read this manual thoroughly before using the device to ensure proper functionality and longevity.
Precaucions de seguretat
To prevent electric shock, fire, or damage to the unit, please observe the following safety guidelines:
- Font d'alimentació: Ensure the input power matches the specified 110V AC 60Hz. Connecting to an incorrect voltagi pot danyar la unitat.
- Ventilació: Do not block ventilation openings. Adequate airflow is essential to prevent overheating. Maintain at least 4 inches (10 cm) of space around the unit.
- Medi ambient: Operate the power supply in a dry, well-ventilated area. Avoid exposure to moisture, rain, or excessive humidity. Do not operate near flammable materials or in explosive atmospheres.
- Protecció de sobrecàrrega: The unit is equipped with overload and short circuit protection. Do not exceed the maximum output current of 50A. If the protection circuit activates, disconnect the load and reduce the current demand before restarting.
- Fusible: The power supply contains an internal fuse (110V, 15A). If the unit fails to power on, check and replace the fuse with one of the same type and rating. Always disconnect the power cord before replacing the fuse.
- Connexions: Ensure all DC output connections are secure and correctly polarized (+ to +, - to -) before applying power. Loose connections can cause arcing and damage.
- Manteniment: Do not attempt to open or service the unit yourself. Refer all servicing to qualified service personnel. Opening the casing voids the warranty.
Producte acabatview
Controls i connectors
Familiarize yourself with the various controls and connection points on your TP50SW power supply.

Figura 1: Front panel of the TekPower TP50SW power supply, showing the analog meter, control knobs, power switch, and cigarette plug output.
- Mesurador analògic: Displays either output voltage (V) or current (A), selectable via the Meter switch.
- Interruptor del comptador: Toggles the analog meter display between Voltage (V) i Ampera (A).
- LED d'alimentació: S'il·lumina quan la unitat està engegada.
- Voltage Botó d'ajust: Allows fine-tuning of the output voltage when the Voltage switch is set to 'ADJ'.
- Botó de compensació de soroll: Used to adjust or minimize switching noise, particularly useful for sensitive communication equipment.
- Interruptor d'encesa / apagat: Toggles the main power to the unit.
- Cigarette Plug (DC Output): Provides a convenient 12V DC output for accessories with a cigarette lighter plug. Limited to 10A.
- Meter Adjust: A small adjustment point, typically for calibrating the analog meter.
- Voltage Switch (13.8V/ADJ): Selects between a fixed 13.8V output or an adjustable output range of 9-15V (controlled by the Voltage Adjust knob).

Figura 2: Rear panel of the TekPower TP50SW power supply, showing the main DC output terminals, AC input, and cooling fan.
- Main DC Output Terminals: Heavy-duty binding posts for connecting high-current devices. Red is positive (+), Black is negative (-). Max 50A.
- Presa d'entrada de CA: For connecting the supplied power cord to a 110V AC 60Hz wall outlet.
- Portafusibles: Contains the main AC input fuse.
- Ventilador de refrigeració: Automatically operates to maintain optimal internal temperature.
Característiques clau
- High Stable 13.8V DC Power Supply for Ham/CB Radio applications.
- 50A Max Current Output for demanding loads.
- Adjustable DC output from 9-15V for versatile use.
- Convenient Cigarette Plug output for automotive accessories.
- Equipped with overload and short circuit protection for enhanced safety.
- Low ripple and noise, suitable for sensitive communication equipment.
Configuració
- Desembalatge: Traieu amb cura la font d'alimentació del seu embalatge. Inspeccioneu la unitat per detectar qualsevol signe de danys durant el transport.
- Col·locació: Place the power supply on a stable, flat surface. Ensure there is ample space (at least 4 inches or 10 cm) around all sides, especially the rear fan and side vents, for proper ventilation. Avoid placing it near heat sources or in direct sunlight.
- Connexió d'alimentació CA:
- Ensure the power supply's ON/OFF switch is in the 'OFF' position.
- Connect the supplied AC power cord to the AC input socket on the rear panel of the power supply.
- Plug the other end of the AC power cord into a standard 110V AC 60Hz wall outlet.
- DC Load Connection:
- Terminals de sortida principals: For high-current devices, connect the positive (+) lead of your device to the red terminal and the negative (-) lead to the black terminal on the rear panel. Ensure connections are tight and secure.
- Cigarette Plug Output: For devices requiring a cigarette lighter connection, insert the device's plug into the cigarette plug socket on the front panel. Note the 10A current limit for this output.
- Always double-check polarity before powering on the unit to prevent damage to your connected equipment.
Instruccions de funcionament
- Encès:
- After all connections are made, switch the Power ON/OFF switch to the 'ON' position. The Power LED will illuminate.
- Selecció del volum de sortidatage:
- Utilitza el Voltage Switch (13.8V/ADJ) al panell frontal:
- Estableix a '13.8V' for a fixed 13.8V DC output.
- Estableix a 'ADJ' per habilitar el Voltage Botó d'ajust, allowing you to vary the output voltage between 9V and 15V. Turn the knob clockwise to increase voltage and counter-clockwise to decrease it.
- Sortida de monitorització:
- Utilitza el Interruptor de comptador to select what the analog meter displays:
- Estableix a V to display the output voltage.
- Estableix a Una to display the output current (ampera).
- Using the Noise Offset Function:
- El Noise Offset Knob can be used to shift the switching frequency of the power supply to avoid interference with sensitive radio equipment. If you experience noise on your radio, slowly adjust this knob to find a setting that minimizes or eliminates the interference.
- Apagat:
- Before disconnecting any load, switch the Power ON/OFF switch to the 'OFF' position.
- Unplug the AC power cord from the wall outlet if the unit will not be used for an extended period.
Manteniment
- Neteja: Keep the unit clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure ventilation openings are free from dust and debris.
- Ventilació: Regularly check that the cooling fan and vents are not obstructed. Proper airflow is crucial for the longevity of the power supply.
- Substitució de fusibles: If the power supply does not turn on, the internal fuse may need replacement.
- Desconnecteu el cable d'alimentació de CA de la presa de corrent.
- Localitzeu el portafusibles al panell posterior.
- Carefully remove the fuse holder cap and extract the old fuse.
- Replace it with a new fuse of the exact same rating (110V, 15A). Using an incorrect fuse can cause damage or fire.
- Securely replace the fuse holder cap.
- Emmagatzematge: When storing the unit for extended periods, ensure it is in a cool, dry place, away from direct sunlight and extreme temperatures.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| La unitat no s'encén. | No AC power, faulty power cord, blown fuse. | Check AC outlet, inspect power cord, replace fuse (see Maintenance section). |
| Sense sortida de CC. | Power switch off, incorrect voltage setting, internal protection activated. | Ensure power switch is ON. Verify Voltage switch is set correctly (13.8V or ADJ). Disconnect load, power cycle unit. |
| Volum de sortidatage or current is unstable. | Loose connections, excessive load, internal fault. | Check all connections. Reduce load to within specifications. If problem persists, contact support. |
| Audible noise or radio interference. | Switching noise from the power supply. | Adjust the Noise Offset knob slowly to find a quieter operating point. Ensure proper grounding of equipment. |
| Unit feels excessively hot. | Blocked ventilation, prolonged high-current operation, ambient temperature too high. | Ensure vents are clear. Reduce load. Operate in a cooler environment. |
Especificacions
| Paràmetre | Valor |
|---|---|
| Potència d'entrada | 110V CA 60Hz |
| Vol. De sortidatage | DC 13.8V (fixed), 9-15V (adjustable) |
| Corrent de sortida màx | 50A |
| Cigarette Plug Output Limit | 10A |
| Ripple Voltage | <= 100mVp-p |
| Classificació de fusibles | 110 V, 15 A |
| Dimensions (L x A x A) | 11 x 7.7 x 3.4 polzades (aprox. 27.9 x 19.6 x 8.6 cm) |
| Pes | 6 lliura (aprox. 2.7 kg) |
| Material | Acer d'aliatge, metall |
| Color | Negre |
Garantia i Suport
The TekPower TP50SW power supply comes with a 1 Year USA warrantyAquesta garantia cobreix els defectes de materials i de fabricació en condicions d'ús normal. Si us plau, conserveu el comprovant de compra per a reclamacions de garantia.
For technical support, warranty service, or inquiries, please contact TekPower customer service. Do not attempt to repair the unit yourself, as this may void your warranty and pose safety risks.
For more information, you may visit the official TekPower weblloc web o poseu-vos en contacte amb els seus centres de servei autoritzats.