1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of your AEM 30-4110 UEGO Air/Fuel Ratio Gauge. The AEM UEGO gauge is designed to provide accurate air/fuel ratio data, which is crucial for optimizing engine performance and preventing damage. It features a digital LED display and a sweeping LED 'needle' that visually indicates AFR changes.

The gauge utilizes a Bosch 4.9 LSU wideband sensor, known for its fast response and accuracy, and does not require free-air calibration. This product is intended for automotive use to monitor engine air/fuel ratios.

2. Què hi ha a la caixa

En obrir el paquet, comproveu que hi hagi tots els components:

AEM 30-4110 UEGO Air/Fuel Ratio Gauge Kit Contents

Figura 2.1: Contents of the AEM 30-4110 UEGO Air/Fuel Ratio Gauge kit, including the gauge, Bosch 4.9 LSU sensor, wiring, weld-in bung, and interchangeable bezels and faceplates.

3. Característiques clau

4. Configuració i instal·lació

Proper installation is critical for accurate readings and reliable operation. It is recommended that installation be performed by a qualified technician.

4.1. Instal·lació del sensor

  1. Select an appropriate location in the exhaust system for the O2 sensor bung. The bung should be welded into the exhaust pipe at a location that ensures the sensor is exposed to exhaust gases but is not subject to excessive heat or condensation.
  2. Weld the provided O2 sensor bung securely into the exhaust pipe.
  3. Thread the Bosch 4.9 LSU wideband O2 sensor into the welded bung. Ensure it is tightened to the manufacturer's specifications to prevent exhaust leaks.
AEM UEGO Gauge with Bosch 4.9 LSU Sensor

Figura 4.1: The AEM UEGO Air/Fuel Ratio Gauge connected to the Bosch 4.9 LSU wideband sensor, ready for installation into the exhaust system.

4.2. Gauge Mounting

The 52mm (2-1/16") gauge housing is designed to fit most standard gauge pods. Choose a mounting location that allows for clear visibility of the gauge display while driving.

4.3. Connexions de cablejat

The gauge connects via two harnesses. The longer harness connects directly to the UEGO sensor. The shorter harness contains four leads for power and analog output:

Ensure all connections are secure and properly insulated to prevent short circuits or signal interference.

4.4. Customization (Bezels and Faceplates)

The gauge includes interchangeable black and silver bezels, and black and white faceplates (for both Air/Fuel Ratio and Lambda Ratio) to match your vehicle's interior. To change them, carefully remove the existing bezel and faceplate and install your preferred combination.

AEM UEGO Gauge with Lambda Ratio Faceplate

Figura 4.2: The AEM UEGO Gauge displaying Lambda Ratio, featuring a black faceplate and silver bezel. This configuration is one of several customizable options.

AEM UEGO Gauge with White Air/Fuel Ratio Faceplate

Figura 4.3: The AEM UEGO Gauge displaying Air/Fuel Ratio, featuring a white faceplate and black bezel. This demonstrates another customizable appearance option.

5. Instruccions de funcionament

Once properly installed and powered, the AEM UEGO gauge will begin displaying air/fuel ratio data.

5.1. Lectura de la pantalla

The gauge displays AFR values within the 10-20 range. Values outside this range may be indicated by a "---" display or other error indicators.

6. Manteniment

The AEM 30-4110 UEGO Air/Fuel Ratio Gauge is designed for minimal maintenance.

7. Solució De Problemes

If you encounter issues with your AEM UEGO gauge, consider the following common troubleshooting steps:

If troubleshooting steps do not resolve the issue, contact AEM technical support for further assistance.

8. Especificacions

Número de model30-4110
MarcaAEM
Calibre Diàmetre52 mm (2-1/16 polzades)
Tipus de sensorBosch 4.9 LSU Wideband O2 Sensor
AFR Display Range10-20 AFR
Sortida analògica0-5V (10-20 AFR range)
MaterialPlàstic
Dimensions del producte (L x A x A)2.17 x 2.76 x 2.17 polzades
Pes de l'article1.39 lliures
UPC840879023157

9. Garantia i Suport

For detailed warranty information, please refer to the official AEM product documentation or contact AEM directly. AEM provides technical support for their products.

An official installation manual in PDF format is available for further reference:

Download AEM 30-4110 Installation Manual (PDF)

For additional support or inquiries, visit the official AEM weblloc o poseu-vos en contacte amb el seu departament d'atenció al client.

Documents relacionats - 30-4110

Preview Instruccions d'instal·lació d'AEM EMS 30-6300 per a Mitsubishi Eclipse, Talon, Laser, Galant VR4
Comprehensive installation guide for the AEM Engine Management System (EMS) P/N 30-6300, designed for 1990-1994 Mitsubishi Eclipse Turbo, Talon Tsi, Dodge/Eagle Talon Tsi, Mitsubishi Eclipse RS, and Mitsubishi Galant VR4. Covers software installation, ECU removal/installation, calibration, tuning, troubleshooting, sensor configuration, wiring, and pinout diagrams.
Preview Manual d'instal·lació de l'arnès de l'adaptador PnP AEM 30-3511 Infinity per a Mitsubishi EVO 8 2003-2005
Manual d'instal·lació complet per a l'arnès adaptador AEM 30-3511 Infinity Plug and Play per a models Mitsubishi EVO 8 2003-2005. Cobreix més deview, kit contents, options, important application notes, installation steps, setup wizard, and pinout information.
Preview Instruccions d'instal·lació del controlador UEGO de tipus calibre AEM 30-4110NS
Instruccions d'instal·lació detallades, especificacions i guia de calibratge per al controlador UEGO de tipus calibre AEM 30-4110NS. Apreneu sobre la compatibilitat dels sensors, el cablejat, la configuració de la sortida analògica i sèrie i les millors pràctiques de muntatge per a una monitorització òptima del motor.
Preview Manual de l'usuari del bloc de bisell i de les esquadres de bisell Woodpeckers
Manual d'usuari complet per al bloc de bisell i l'esquadre de bisell Woodpeckers, que detalla les característiques, les opcions d'ajust de l'angle, l'ajust de la pretensió i les instruccions d'ús per a la precisió en la fusteria.
Preview Guia d'instal·lació del sistema de monitorització de mesuradors de tancs OPW M1500 SiteSentinel iTouch
Guia d'instal·lació del sistema de monitorització de mesuradors de tancs OPW M1500 SiteSentinel iTouch, que cobreix els procediments d'instal·lació del controlador, les sondes i els sensors.
Preview AEM X-Series Gauge OBD-II Instruction Manual
Comprehensive instruction manual for the AEM X-Series Gauge OBD-II, covering installation, operation, features, and troubleshooting. Learn how to connect, use, and maintain your OBD-II gauge for optimal performance.