1. Introducció
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Amerec 9006-123 12KW Commercial Steam Boiler. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.
The Amerec AI-12 commercial steam shower generator is designed for demanding commercial health club steam rooms, capable of serving spaces up to 550 cubic feet. It includes two 3/4" NPT steam heads. A control unit is required and sold separately.
2. Informació de seguretat
ADVERTIMENT: La instal·lació, l'ajustament, l'alteració, el servei o el manteniment inadequats poden causar danys a la propietat, lesions o la mort. Llegiu atentament les instruccions d'instal·lació, funcionament i manteniment abans d'instal·lar o donar servei a aquest equip.
- Desconnecteu sempre l’alimentació abans de donar servei a la unitat.
- Ensure all electrical connections are made by a qualified electrician and comply with local and national electrical codes.
- All plumbing connections must be made by a qualified plumber and comply with local and national plumbing codes.
- Do not operate the steam boiler if it is damaged or malfunctioning.
- Mantingueu els nens i el personal no autoritzat allunyats de la unitat durant el funcionament.
- Steam is hot and can cause severe burns. Exercise extreme caution.
3. Producte acabatview
The Amerec 9006-123 is a robust commercial steam boiler designed for high-demand environments. It features durable construction and efficient steam generation for consistent performance.
Figure 1: Amerec 9006-123 12KW Commercial Steam Boiler. This image shows the front and side view of the grey-colored steam boiler unit, featuring control panels with digital displays, various plumbing connections, and electrical conduits. Red-handled valves are visible on the left side, indicating water level monitoring.
4. Configuració i instal·lació
Installation of the Amerec 9006-123 steam boiler requires professional expertise. It must be installed by a licensed electrician and plumber in accordance with all local and national codes.
4.1 Requisits d'ubicació
- Install the unit in a dry, well-ventilated area, protected from freezing temperatures.
- Assegureu-vos que hi hagi prou espai lliure al voltant de la unitat per al manteniment i la reparació.
- The unit should be installed as close as possible to the steam room to minimize steam line length.
4.2 Connexions elèctriques
- The unit operates on 208V, 3 Phase power.
- Connect the boiler to a dedicated circuit with appropriate overcurrent protection.
- Ensure proper grounding as per electrical codes.
4.3 Connexions de fontaneria
- Connect a cold water supply line to the boiler's water inlet.
- Install a drain line from the boiler to an approved floor drain.
- Connect the steam line from the boiler to the steam heads within the steam room. Ensure proper pitch for condensate return.
5. Instruccions de funcionament
The Amerec 9006-123 requires a separate control unit for operation. Refer to the control unit's manual for specific operating procedures.
- Encès: Ensure the main power supply to the boiler is switched on.
- Subministrament d'aigua: Verify that the water supply valve to the boiler is open.
- Control Unit Activation: Use the external control unit (sold separately) to activate the steam generation cycle.
- Configuració de la temperatura: Set the desired steam room temperature via the control unit.
- Generació de vapor: The boiler will begin heating water to produce steam. This process may take several minutes depending on the initial water temperature and desired steam output.
- Apagar: To turn off the unit, use the external control unit or disconnect the main power supply.
Nota: The boiler will automatically fill with water and maintain the water level during operation. Low water cut-off features are integrated for safety.
6. Manteniment
Regular maintenance is crucial for the longevity and efficient operation of your Amerec steam boiler. Always disconnect power before performing any maintenance.
6.1 Daily/Weekly Checks
- Visually inspect the unit for any leaks or unusual noises.
- Ensure the water level sight glass (if present) shows an appropriate water level.
6.2 Monthly/Quarterly Maintenance
- Escórrer i buidar: Periodically drain the boiler to remove sediment buildup. Follow manufacturer guidelines for frequency based on water quality.
- Element Inspection: Inspect heating elements for scale buildup. Descale as necessary using approved descaling solutions.
- Comprovació de la vàlvula de seguretat: Test the pressure relief valve to ensure it operates correctly.
6.3 Servei professional anual
It is recommended to have the unit inspected and serviced annually by a qualified technician to ensure optimal performance and safety.
7. Solució De Problemes
Abans de contactar amb l'atenció al client, review els següents problemes i solucions habituals.
| Problema | Causa possible | Solució |
|---|---|---|
| Sense producció de vapor | No power; water supply off; low water level; faulty heating element; control unit issue. | Check power supply and circuit breaker; open water supply valve; check water level; consult technician for element/control unit. |
| Vapor insuficient | Scale buildup on elements; steam room too large; steam line leaks. | Descale elements; verify steam room size is within specifications; check steam lines for leaks. |
| Fuites d'aigua | Loose plumbing connections; damaged seals/gaskets. | Tighten connections; replace damaged components. |
| Unit not filling with water | Water supply off; clogged inlet filter; faulty fill valve. | Open water supply; clean filter; consult technician for fill valve. |
For issues not listed or if solutions do not resolve the problem, contact Amerec customer support or a qualified service technician.
8. Especificacions
| Característica | Detall |
|---|---|
| Marca | Amerec |
| Número de model | 9006-123 |
| Wattage | 12000 watts (12KW) |
| Voltage | 208 Volts |
| Fase | 3 Fase |
| Estil | Instal·lació interior |
| Steam Room Size Capacity | Up to 550 cubic feet |
| Steam Heads Included | Two 3/4" NPT |
| Unitat de control | Required, sold separately |
| UPC | 646028001133 |
9. Garantia i Suport
For warranty information, please refer to the documentation provided with your purchase or visit the official Amerec website. For technical support, replacement parts, or service inquiries, please contact Amerec customer service directly.
Amerec Contact Information: Please refer to the official Amerec weblloc web o la documentació de compra per obtenir les dades de contacte més actualitzades.