1. Introducció
The Power Probe IV is an advanced automotive diagnostic tool designed to assist technicians in testing electrical circuits and signals within vehicles. It combines multiple diagnostic functions into a single, ergonomic device, providing detailed information for efficient troubleshooting. This manual provides essential information for the safe and effective use of your Power Probe IV.
For more information, visit the official Power Probe weblloc: Power Probe IV

Image 1.1: The Power Probe IV diagnostic tool kit, including the main unit, carrying case, and various connection accessories.
2. Característiques clau
The Power Probe IV offers a comprehensive set of features for automotive electrical diagnostics:
- Power and Ground Supply: Capable of supplying battery ground and power for functional component testing.
- Digital Volt and Ohmmeter: Integrated for precise circuit testing, measuring AC/DC Voltage, Resistance, Hertz, Frequency, and Pulse Width.
- Large Color LCD Screen: Provides clear, easy-to-read information with an intuitive user menu.
- Prova de senyal: Supports AC-RMS, AC peak-to-peak, frequency, and pulse width measurements.
- Disseny ergonòmic: Features a heavy-duty, water and solvent-resistant housing for durability and comfortable use.
- Protecció de circuits: Equipped with an automatic resetting 8 Amp tallacircuits.
- Vol. Amplitage Rang: Operates within a 12-24 Volt range.
- Compatibilitat: Works with all Power Probe test leads and accessories.

Image 2.1: Visual representation of the Power Probe IV's key features and design elements.
3. Què hi ha a la caixa
Your Power Probe IV package typically includes the following items:
- Power Probe IV Unit (Model PP401AS)
- Battery Clip Set
- Manual d'instruccions
- Funda protectora de transport
4. Configuració i connexió inicial
Before using your Power Probe IV, ensure a proper connection to the vehicle's battery.
- Connect the Red Clip: Attach the red battery clip to the positive (+) terminal of the vehicle's 12V or 24V battery.
- Connect the Black Clip: Attach the black battery clip to the negative (-) terminal of the vehicle's battery or a suitable chassis ground point.
- Encès: The Power Probe IV will power on automatically once connected. The LCD screen will illuminate, indicating it is ready for use.
Nota de seguretat: Always ensure secure connections to prevent accidental disconnections or short circuits. Do not connect the Power Probe IV to voltages exceeding its specified operating range (12-24V).
5. Instruccions de funcionament
The Power Probe IV features an intuitive interface with various modes for different diagnostic tasks. Familiarize yourself with the tool's controls and display.
5.1 Tool Overview i Controls

Image 5.1: Diagram illustrating the main components and controls of the Power Probe IV.
- Consell de la sonda: Used to contact circuits for testing.
- Llanterna: Il·lumina la zona de treball.
- Red/Green LEDs: Indicate positive (red) or negative (green) voltage at the probe tip.
- Pantalla en color: Displays measurement data and menu options.
- CLR Button (Left): Clears minimum/maximum readings or scrolls up in menus.
- MODE Button (Center): Selecciona diferents modes de funcionament.
- Interruptor basculant: Applies battery positive or negative voltage to the probe tip.
- Ponent: Provides audible feedback for certain functions.
5.2 Diagnostic Modes and Functions
Premeu el botó MODE button to cycle through the available diagnostic modes:

Imatge 5.2: acabatview of the Power Probe IV's primary diagnostic capabilities.
- Power Up Mode:
Actively tests components like motors, lights, and fans by supplying power or ground. Use the rocker switch to apply voltage to the probe tip.

Image 5.3: Using the Power Probe IV to measure voltage at a battery terminal.
- Min/Max Readings:
Captures and displays minimum and maximum voltage spikes or drop-outs in circuits, useful for intermittent fault detection.
- Continuity & Resistance:
Tests the continuity of wires and components, and measures resistance (Ohms) to identify open circuits or shorts.

Image 5.4: Testing a fuse for continuity within a vehicle's fuse box.
- Freqüència (Hz):
Measures the frequency of signals, essential for testing computer sensors and Pulse Width Modulation (PWM) circuits.

Image 5.5: The Power Probe IV displaying a frequency reading.
- Driver Test Mode:
Safely tests computer circuits that control relays, solenoids, and motors without causing damage.
- AC RMS, Peak to Peak:
Measures AC Root Mean Square (RMS) and Peak-to-Peak voltage outputs from alternators and sensors to verify correct operation.

Image 5.6: AC RMS Voltagvisualització.

Image 5.7: AC Peak to Peak Voltagvisualització.
- Fuel Injector Test Mode:
Reads operating values of individual fuel injectors, allowing technicians to compare them and identify faulty injectors.

Image 5.8: Testing a fuel injector with the Power Probe IV.
6. Manteniment
Proper maintenance ensures the longevity and accuracy of your Power Probe IV.
- Neteja: Neteja l'eina amb anuncisamp drap per eliminar la brutícia i la pols. Eviteu productes químics agressius o netejadors abrasius.
- Emmagatzematge: Store the Power Probe IV in its protective carrying case when not in use to prevent damage. Keep it in a dry environment.
- Inspecció del cable: Regularly inspect the power cable and test leads for any signs of wear, cuts, or damage. Replace damaged components immediately.
- Consell de la sonda: Ensure the probe tip is clean and sharp for optimal contact.
7. Solució De Problemes
If you encounter issues with your Power Probe IV, consider the following common troubleshooting steps:
| Problema | Causa possible | Solució |
|---|---|---|
| L'eina no s'encén. | Incorrect or loose battery connection. Vehicle battery is dead. | Ensure red and black clips are securely connected to the correct battery terminals. Verify vehicle battery voltage. |
| No reading on screen. | Probe tip not making good contact. Circuit is open or dead. | Ensure firm contact with the circuit. Check for continuity or voltage al circuit. |
| L'interruptor automàtic salta amb freqüència. | Overload on the circuit being tested. Short circuit detected. | Reduce the load on the circuit or investigate for a short circuit before reapplying power. The breaker resets automatically. |
| Lectures inexactes. | Poor connection. Damaged probe tip or cable. | Clean probe tip and ensure solid connection. Inspect cables for damage. |
If problems persist, contact Power Probe customer support for assistance.
8. Especificacions
| Atribut | Detall |
|---|---|
| Número de model | PP401AS |
| Marca | Sonda d'alimentació |
| Font d'alimentació | Battery Powered (Vehicle Battery 12-24V) |
| Pes de l'article | 3 lliures |
| Dimensions del producte | 4 x 8 x 4 polzades |
| Longitud del cable | 23 peus (aprox.) |
| Interruptor | Automatic Resetting 8 Amp |
| Mostra | LCD a color gran |
9. Garantia i Suport
For warranty information, technical support, or service inquiries, please refer to the official Power Probe weblloc web o poseu-vos en contacte amb el seu departament d'atenció al client. Conserveu el rebut de compra com a comprovant de compra.
Optional protection plans may be available for extended coverage. Please check with your retailer or Power Probe for details.