1. Introducció
This user manual provides comprehensive instructions for the installation, operation, and maintenance of the CAME ZBX-10 control board. The ZBX-10 is designed for controlling automatic gate systems, ensuring reliable and safe operation. Please read this manual carefully before proceeding with installation or use to ensure proper functionality and to prevent damage or injury.
2. Instruccions de seguretat
Always adhere to local electrical codes and safety regulations during installation and maintenance. Installation should only be performed by qualified personnel. Disconnect power before performing any wiring or maintenance. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure the main power supply is disconnected before any electrical connections are made or adjusted.
- Utilitzeu l'equip de protecció individual (EPI) adequat durant la instal·lació.
- Do not expose the control board to moisture or extreme temperatures.
- Verifiqueu que totes les connexions siguin segures i correctes abans d'aplicar l'alimentació.
- Keep children and unauthorized persons away from the gate area during operation and maintenance.
3. Producte acabatview
The CAME ZBX-10 is a robust control board designed for managing the movement of automatic gates. It features various inputs and outputs for connecting motors, safety devices, and command accessories. Key components include power terminals, motor connection terminals, safety input terminals, and programming buttons.

Figure 1: An isometric view of the CAME ZBX-10 control board, showing various electronic components, capacitors, and terminal blocks for connections. Labels such as 'POWER', '24 0', '10 11 E 8', '1 2 3P 7', '10TS 2CXCY FO FAF' are visible on the board, indicating different connection points and functionalities.
The board includes terminals for 24V power supply, motor connections, and various control inputs. The digital display and buttons allow for configuration and status monitoring.
4. Configuració i instal·lació
Before beginning installation, ensure all necessary tools and components are available. Mount the control board in a protective enclosure, away from direct weather exposure and vibrations. Follow the wiring diagram provided with your gate system for specific connections.
- Muntatge: Securely mount the ZBX-10 control board inside a suitable, weather-resistant enclosure. Ensure adequate ventilation.
- Connexió d'alimentació: Connect the main power supply to the designated terminals (e.g., '24 0' or 'POWER' as indicated on the board). Ensure correct voltage i polaritat.
- Connexió del motor: Connect the gate motor(s) to the motor output terminals. Refer to the motor's specific wiring requirements.
- Safety Device Connection: Connect safety photocells, emergency stop buttons, and other safety devices to their respective input terminals (e.g., 'FO FAF').
- Command Device Connection: Connect remote control receivers, keypads, or push buttons to the command input terminals (e.g., '10 11 E 8').
- Posada a terra: Ensure proper grounding of the control board and the gate system components to prevent electrical hazards.
- Engegada inicial: After all connections are verified, apply power to the control board. Observe the status indicators and digital display for initial diagnostics.
5. Instruccions de funcionament
The CAME ZBX-10 control board allows for various operational modes and programming options. Refer to the detailed programming guide for specific parameter adjustments.
- Funcionament bàsic: Once powered, the board is ready to receive commands from connected devices. A typical command will initiate the gate opening or closing cycle.
- Modes de programació: Access programming modes using the onboard buttons and digital display. Common settings include motor force, opening/closing speeds, pause time, and safety input configurations.
- Anulació manual: In case of power failure or system malfunction, most gate systems connected to the ZBX-10 will have a manual release mechanism. Consult your gate system's manual for details.
6. Manteniment
Regular maintenance ensures the longevity and reliable operation of your CAME ZBX-10 control board and the associated gate system. Perform checks at least annually, or more frequently in high-use environments.
- Desconnexió d'alimentació: Always disconnect power to the control board before performing any maintenance.
- Inspecció visual: Check for any signs of wear, corrosion, or loose connections on the board and its terminals.
- Neteja: Gently clean the board with a soft, dry brush or compressed air to remove dust and debris. Do not use liquids.
- Comprovació del terminal: Ensure all terminal screws are tight and connections are secure.
- Prova de funcionalitat: After maintenance, test all safety devices and operational commands to ensure proper function.
7. Solució De Problemes
This section provides solutions for common issues. For complex problems, consult a qualified technician.
| Problema | Causa possible | Solució |
|---|---|---|
| Gate does not respond to commands. | No power, faulty remote, safety device activated, loose wiring. | Check power supply. Replace remote battery. Inspect safety devices for obstructions or faults. Verify all wiring connections. |
| La porta s'obre però no es tanca. | Safety photocells obstructed or misaligned, closing limit switch issue. | Clear photocell path, clean lenses, realign photocells. Check limit switch operation. |
| El motor funciona però la porta no es mou. | Motor clutch disengaged, mechanical obstruction. | Check if the gate is in manual release mode. Inspect for physical obstructions in the gate's path or mechanism. |
8. Especificacions
Technical specifications for the CAME ZBX-10 Control Board:
- Fabricant: VA VENIR
- Model: ZBX-10
- Pes de l'article: 1 quilograms
- ASIN: B00P92LOGS
- Primera data disponible: 11 de març de 2020
- Number of Package Items: 1
9. Garantia i Suport
For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized CAME dealer. Technical support can be obtained through your supplier or by visiting the official CAME weblloc web per obtenir dades de contacte i més recursos.