Remco 5517-1E1-82B

Remco 5.3 GPM Demand Pump User Manual

Model: 5517-1E1-82B

1. Introducció

The Remco 5500 series 5.3 GPM Demand Pump (Model: 5517-1E1-82B) is a professional-grade solution designed for performance and efficiency in various applications, particularly agricultural spray applications. This pump features a 60 PSI pressure setting and a sealed 12-volt electric motor, engineered to operate reliably even in harsh environments.

Constructed with durable components, the 5500 Series pump is built to withstand long and continuous duty cycles. Its materials are compatible with common agricultural chemicals, including herbicides, fertilizers, and insecticides. This manual provides essential information for the safe and effective setup, operation, and maintenance of your Remco pump.

Característiques principals:

  • Qualitat de grau professional
  • 5.3 GPM (20.06 LPM) flow rate, 60 PSI (4.1 Bar) on Demand
  • Made In the U.S.A.
  • 6" length 14 AWG wire leads with SAE 2 pin connector
  • Highest flow rate and lowest operating temperature at spray pressures
  • Chemically compatible with common Agricultural chemicals
  • 100% Factory Tested
  • Completely Sealed Motor
  • Low Heat and Power Consumption
  • Superior Vertical Priming
Remco 5.3 GPM Demand Pump, side view

Figure 1: Remco 5.3 GPM Demand Pump (Model 5517-1E1-82B)

2. Informació de seguretat

Always read and understand all instructions before operating the pump. Failure to follow safety guidelines can result in injury or damage to the equipment.

  • Ensure the power source is disconnected before performing any maintenance or installation.
  • Wear appropriate personal protective equipment (PPE) when handling chemicals or operating the pump.
  • Do not exceed the maximum liquid temperature of 140°F (60°C).
  • For optimal performance and motor life, ensure the motor surface temperature does not exceed 150°F (66°C). The motor is not equipped with thermal protection.
  • Verify chemical compatibility before use to prevent damage to the pump components.
  • Keep the pump away from flammable materials and open flames.
  • Assegureu-vos una ventilació adequada durant el funcionament.

3. Configuració i instal·lació

Proper installation is crucial for the optimal performance and longevity of your Remco pump. Follow these steps carefully:

3.1 Muntatge de la bomba

  • Mount the pump in a secure, dry location, protected from direct weather exposure.
  • Ensure adequate space around the pump for ventilation and access for maintenance.
  • The pump can self-prime up to 14 feet (4.0 m) vertically. Position it as close as possible to the fluid source for best results.

3.2 Connexions elèctriques

  • The pump operates on 12 VDC. Connect the 14 AWG wire leads (6" or 12" 2-Pin Mold / Custom Connection) to a suitable 12-volt power source.
  • Ensure correct polarity: Red wire is positive (+), Black wire is negative (-).
  • Use appropriate fusing for the electrical circuit to protect the pump and power supply.
Close-up of the pump's wire leads with SAE 2-pin connector

Figure 2: SAE 2-pin connector on the pump's wire leads

3.3 Connexions de fluids

  • The pump features 3/4" Quick Attach Ports for fluid connections.
  • Connect the inlet port to your fluid supply and the outlet port to your application system.
  • Assegureu-vos que totes les connexions siguin segures i sense fuites.
Remco 5.3 GPM Demand Pump with dimensions labeled

Figure 3: Pump dimensions for installation planning

4. Instruccions de funcionament

The Remco 5.3 GPM Demand Pump operates in a demand mode, meaning it will run when there is a demand for fluid and shut off when the demand ceases or pressure is reached.

4.1 Posada en marxa inicial

  1. Ensure all fluid connections are tight and the pump is securely mounted.
  2. Verify the fluid source is open and available to the pump.
  3. Connect the pump to the 12 VDC power supply. The pump may run briefly to prime itself.
  4. Open the discharge valve or nozzle to allow fluid to flow. The pump will start automatically.
  5. Once the system is primed and air is purged, the pump will operate smoothly.

4.2 Chemical Application

This pump is designed for use with various agricultural chemicals, including herbicides, fertilizers, and insecticides. Always ensure the chemicals used are compatible with Viton valves and Santoprene diaphragms to prevent damage.

  • Refer to the chemical manufacturer's guidelines for proper mixing ratios and application rates.
  • Avoid running the pump dry for extended periods, as this can cause damage. The pump has dry run capability for short durations.

5. Manteniment

Regular maintenance will extend the life and ensure the reliable operation of your Remco pump.

5.1 Post-Use Cleaning

  • After every use, especially when pumping chemicals, it is highly recommended to rinse the pump thoroughly with clean water.
  • Run clean water through the pump for several minutes to flush out any residual chemicals.

5.2 Temperature Management

  • The maximum liquid temperature is 140°F (60°C).
  • The maximum motor temperature is 180°F (82°C). However, for user safety, optimal performance, and maximum motor life, the motor surface temperature should not exceed 150°F (66°C).
  • Monitor the pump's temperature during prolonged operation. If it becomes excessively hot, allow it to cool down.

5.3 Emmagatzematge

  • If storing the pump for an extended period, ensure it is thoroughly cleaned and drained of all liquids.
  • Store in a dry, frost-free environment.

6. Solució De Problemes

This section provides solutions to common issues you might encounter with your Remco pump. If the problem persists, contact customer support.

ProblemaCausa possibleSolució
La bomba no funcionaNo power; Loose electrical connection; Blown fuse; Motor failureCheck power supply; Secure connections; Replace fuse; Contact support
Low flow or pressureClogged inlet/outlet; Air leak in suction line; Worn diaphragm/valves; Low voltageClear obstructions; Check for leaks; Inspect/replace components; Verify voltage
La bomba funciona contínuamentLeak in system; Pressure switch malfunction; Air in systemCheck for leaks; Contact support; Bleed air from system
Soroll excessiuAir in system; Loose mounting; Debris in pumpBleed air; Secure mounting; Inspect and clean pump

7. Especificacions tècniques

AtributDetall
MarcaRemco
Número de model5517-1E1-82B
TipusBomba de diafragma de 5 cambres
ModeDemanda
Voltage12 VDC
Caudal màxim5.3 GPM (20.06 LPM)
Configuració de la pressió60 PSI (4.1 bar)
Fluid Port3/4" Quick Attach Ports
VàlvulesViton
DiafragmaSantoprè
Conductors de filferro14 AWG - 6" OR 12" 2-Pin Mold / Custom Connection
AutoadaptacióUp to 14' (4.0 m) vertically
Cicle de treballIntermitent
Dry Run Capability
Temperatura màxima del líquid140 °C (60 °F)
Max Motor Temperature180°F (82°C) (Recommended max 150°F / 66°C for optimal life)
Dimensions del producte10.8 cm de llargada x 5.3 cm d'amplada x 6 cm d'alçada
Pes de l'article7.96 lliures

8. Garantia i Suport

For warranty information, technical support, or replacement parts, please contact Remco customer service. Keep your purchase receipt and model number handy when contacting support.

For more information, visit the official Remco weblloc web o poseu-vos en contacte amb la seva línia d'atenció al client.

Documents relacionats - 5517-1E1-82B

Preview REMCO Professional Grade Pump Products Catalog
Comprehensive catalog of REMCO's professional-grade diaphragm pumps, including series like 3300, 3200, 5500, Zeus, SmoothFlo, RollMax, and PowerRV, along with accessories and custom pump solutions.
Preview Bombes Remco sèrie 5500: Pautes de funcionament i instal·lació
Pautes completes d'operació i instal·lació per a les bombes Remco de la sèrie 5500, que cobreixen les precaucions de seguretat, el muntatge, la fontaneria, les connexions elèctriques, els procediments d'instal·lació, el manteniment, la resolució de problemes i les peces de recanvi.
Preview Bombes REMCO Economy Plus 2200 2400: Manual d'operació i instal·lació
Pautes completes d'operació i instal·lació, especificacions, dimensions i resolució de problemes per a les bombes REMCO Economy Plus sèries 2200 i 2400. Inclou una llista de peces i informació sobre la garantia d'aquestes bombes industrials assequibles i d'alta qualitat.
Preview REMCO Accumulator/Pulsation Dampener Tank Installation & Maintenance Manual
Detailed installation, maintenance, troubleshooting, and warranty information for the REMCO RACT820-NPT and RACT820-JG Accumulator/Pulsation Dampener Tanks. Learn how to optimize pump performance and system longevity.
Preview Remco STAR 4 u 1: Univerzalni Daljinski Upravljač - Uputstvo i Kodovi
Saznajte kako da podesite i koristite vaš Remco STAR 4 u 1 univerzalni daljinski upravljač. Pronađite uputstva za pretragu kodova, funkciju učenja i rešavanje problema za TV, STB, SAT, DVD i BD uređaje.
Preview Bombes de diafragma REMCO ProFlo 3300, 5500, FatBoy: Manual de funcionament, instal·lació i reparació
Guia completa d'operació, instal·lació, resolució de problemes i peces per a les bombes de diafragma REMCO ProFlo 3300, 5500 i FatBoy. Inclou gràfics de rendiment, dades d'augment de calor i informació sobre la garantia estàndard.