IBM 81Y4494

IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller User Manual

Instruccions completes per a la instal·lació, el funcionament i el manteniment.

Introducció

This manual provides detailed instructions for the IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller. It covers the necessary steps for proper installation, configuration, operation, and troubleshooting to ensure optimal performance and longevity of your hardware. Please read this manual thoroughly before attempting any installation or operation.

Configuració i instal·lació

Proper installation is crucial for the functionality of the IBM 81Y4494 ServerRAID H1110 controller. Follow these steps carefully.

1. Precaucions de seguretat

  • Always disconnect power from the server before opening the chassis.
  • Porteu una polsera antiestàtica per evitar danys per descàrrega electrostàtica (ESD) als components.
  • Handle the controller by its edges; avoid touching components or connectors.

2. Instal·lació física

  1. Xassís de servidor obert: Power down the server and disconnect all power cables. Open the server chassis according to the server manufacturer's instructions.
  2. Localitza la ranura PCIe: Identify an available PCI Express (PCIe) slot on the server's motherboard. The IBM 81Y4494 requires a PCIe x8 or x16 slot for full bandwidth, though it can operate in a smaller slot if physically compatible.
  3. Treure la coberta de la ranura: Carefully remove the metal slot cover corresponding to the chosen PCIe slot.
  4. Insereix el controlador: Align the controller with the PCIe slot. Apply even, firm pressure to seat the card fully into the slot. Ensure the retention clip or screw secures the card.
IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller installed in a server slot

Imatge: Lateral view of the IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller, showing the PCIe connector and bracket, ready for installation into a server. Note the heatsink for thermal management.

  1. Connect SAS/SATA Cables: Connect the appropriate SAS or SATA data cables from your storage devices (hard drives, SSDs) to the ports on the IBM 81Y4494 controller. Ensure secure connections.
  2. Xassís tancat: Once all connections are made, close the server chassis and reconnect power cables.

3. Instal·lació del controlador

After physical installation, power on the server. The operating system may automatically detect and install a generic driver. For optimal performance and full functionality, it is recommended to download and install the latest drivers from the official IBM support weblloc web per al vostre sistema operatiu específic.

  • Visit the IBM Support weblloc.
  • Cerca "81Y4494" or "ServerRAID H1110".
  • Download the appropriate driver package for your server's operating system.
  • Follow the provided instructions for driver installation.

Funcionament del controlador

The IBM 81Y4494 ServerRAID H1110 functions primarily as a Host Bus Adapter (HBA), providing direct connectivity to SAS and SATA storage devices. It typically operates in a "JBOD" (Just a Bunch Of Disks) mode, allowing the operating system to manage individual drives or implement software RAID.

1. Drive Detection

Upon successful driver installation and system boot, connected SAS/SATA drives should be detected by the operating system. You can verify this through the operating system's disk management utilities.

A dalt view of IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller

Imatge: Superior view of the IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller, showing the various integrated circuits, capacitors, and connectors. The SAS/SATA ports are visible for connecting storage devices.

2. Storage Configuration

For advanced storage configurations, such as software RAID (e.g., RAID 0, RAID 1, RAID 5, RAID 10), use the tools provided by your operating system (e.g., Windows Storage Spaces, Linux mdadm) or third-party software solutions. The H1110 provides the physical interface; the operating system handles the logical volume management.

3. Seguiment

Monitor the health and status of your connected drives using the operating system's built-in tools or specialized monitoring software. Some operating systems may provide basic information about the HBA itself.

A baix view of IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller

Imatge: Part inferior view of the IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller, displaying the solder points and traces on the printed circuit board. This side typically faces away from the user during installation.

Manteniment

Regular maintenance helps ensure the reliability and performance of your controller.

  • Actualitzacions de firmware: Periodically check the IBM support website for firmware updates for the H1110 controller. Firmware updates can provide performance improvements, bug fixes, and compatibility enhancements. Follow the provided instructions carefully when performing firmware updates.
  • Inspecció física: During server maintenance, visually inspect the controller for any signs of damage, loose connections, or excessive dust accumulation.
  • Neteja: If necessary, gently clean the controller with compressed air to remove dust. Ensure the server is powered off and disconnected from power before cleaning.

Resolució de problemes

If you encounter issues with your IBM 81Y4494 ServerRAID H1110 controller, refer to the following troubleshooting steps.

ProblemaCausa possibleSolució
Controller not detected by OS
  • Not properly seated in PCIe slot.
  • Controladors incorrectes o que falten.
  • Faulty PCIe slot.
  • Torneu a col·locar el controlador fermament.
  • Install the latest drivers from IBM.
  • Try a different PCIe slot.
Drives not detected
  • Loose or faulty SAS/SATA cables.
  • Unitats sense alimentació.
  • Unitats defectuoses.
  • Check and reseat all data and power cables.
  • Assegureu-vos que les unitats reben alimentació.
  • Feu proves de conducció individualment si és possible.
Mal rendiment
  • Outdated drivers/firmware.
  • Sobreescalfament.
  • Incorrect PCIe slot (e.g., x1 slot).
  • Actualitzar els controladors i el firmware.
  • Ensure adequate server cooling.
  • Install in a PCIe x8 or x16 slot.

For more complex issues, consult the IBM support weblloc o contacteu amb l'assistència tècnica.

Especificacions

Key technical specifications for the IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller:

  • Fabricant: IBM
  • Número de model: 81Y4494
  • Interfície de maquinari: SAS (SCSI connectat en sèrie)
  • Factor de forma: PCIe (PCI Express)
  • Unitats compatibles: SAS and SATA hard drives and solid-state drives
  • Funcionalitat: Host Bus Adapter (HBA) for direct drive connectivity
  • Data de primera disponibilitat: 6 de desembre de 2014

Garantia i Suport

For information regarding the warranty coverage for your IBM 81Y4494 ServerRAID H1110 SAS/SATA Controller, please refer to the original purchase documentation or visit the official IBM support website. Warranty terms and conditions may vary based on region and purchase date.

For technical assistance, driver downloads, firmware updates, and additional documentation, please visit the official IBM support portal:

Suport d’IBM Weblloc

Documents relacionats - 81Y4494

Preview Sistema de visualització d'informació IBM 3270: Descripció de la unitat de control 3274 i guia del programador
Un manual tècnic complet que detalla el sistema de visualització d'informació IBM 3270, amb un enfocament específic en la unitat de control IBM 3274. Cobreix aspectes funcionals i de programació, fluxos de dades, operacions i integració dins d'entorns IBM.
Preview Sistema de monitorització de disc IBM 1130, versió 2: Guia del programador i de l'operador
Un manual tècnic complet que detalla el sistema de monitorització de disc IBM 1130, versió 2. Aquesta guia cobreix la configuració del sistema, les tècniques de programació, els procediments operatius i els programes d'utilitat per al sistema informàtic IBM 1130, dirigit a programadors i operadors.
Preview Sistema de monitorització de disc IBM 1130, versió 2: Guia de programació i de l'operador
Aquesta guia completa proporciona els procediments essencials d'operació i manteniment per al sistema IBM 1130 Disk Monitor, versió 2. Inclou una secció introductòria per a nous usuaris, consells de programació i informació detallada sobre els registres de control del sistema de monitorització i els missatges d'error.
Preview Guia d'instal·lació i proves de l'IBM 7094 Model 2 per a enginyers de clients
Manual oficial d'instal·lació i proves per al sistema de processament de dades IBM 7094 Model 2. Cobreix els procediments CE, el cablejat, la configuració del sistema, la seguretat i els diagnòstics per a aquest vin.tagl'ordinador.
Preview Guia d'inici ràpid de l'IBM Spectrum Control 5.2.13: instal·lació i posteriorview
Una guia d'inici ràpid per instal·lar i configurar IBM Spectrum Control versió 5.2.13, que cobreix les característiques del producte, les llicències i els procediments d'instal·lació pas a pas per al programari de gestió d'emmagatzematge.
Preview Guia de productes del grup de programari d'IBM: informació completaview de Solucions de Middleware
Exploreu la Guia de productes d'IBM Software Group (SWG), un recurs complet que detalla els productes, les capacitats i les relacions de middleware d'IBM. Ideal per a venedors i socis comercials que busquen entendre i vendre solucions de programari d'IBM.