1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the Watt Stopper UT-305-3 Ultrasonic Ceiling Occupancy Sensor. This device is designed to detect occupancy in a 360-degree field of view, covering up to 2000 square feet, and control lighting loads based on occupancy. It utilizes ultrasonic technology for reliable detection and operates on a 24 VDC power supply.

Please read this manual thoroughly before installation and operation to ensure proper functioning and safety.

2. Informació de seguretat

3. Producte acabatview i Característiques

The Watt Stopper UT-305-3 is an advanced ultrasonic occupancy sensor designed for ceiling mount applications. Its key features include:

Watt Stopper UT-305-3 Ultrasonic Ceiling Occupancy Sensor, front view

Figura 1: Davant view of the Watt Stopper UT-305-3 Ultrasonic Ceiling Occupancy Sensor. This image shows the white, circular housing with the ultrasonic transducer visible in the center, designed for discreet ceiling installation.

4. Configuració i instal·lació

The UT-305-3 sensor is designed for ceiling mounting. Follow these general steps for installation:

  1. Desconnexió d'alimentació: Ensure all power to the installation area is turned off at the circuit breaker.
  2. Lloc de muntatge: Select a central ceiling location within the desired coverage area (up to 2000 sq ft). Avoid placing the sensor directly above heat sources or in areas with significant air currents that could cause false detections.
  3. Cablejat: Connect the sensor to a Watt Stopper Class 2 power supply (24 VDC) according to the wiring diagram provided with the power supply. The sensor provides an isolated relay output for controlling the lighting load.
  4. Muntatge del sensor: Securely mount the sensor to the ceiling using appropriate hardware. The sensor has a compact design with dimensions of approximately 4.5 inches diameter and 1.02 inches height.
  5. Restauració i proves d'energia: Once wiring and mounting are complete, restore power and test the sensor's functionality.
Watt Stopper UT-305-3 product box showing model number and UPC

Figura 2: Packaging for the Watt Stopper UT-305-3 sensor. The label clearly displays the model number UT-305-3, 360-degree occupancy sensor, 40kHz, 2000ft² coverage, and the UPC 00754182915194, confirming product details.

5. Instruccions de funcionament

The UT-305-3 sensor operates automatically once installed and powered. It continuously monitors the area for occupancy using ultrasonic technology.

6. Manteniment

The Watt Stopper UT-305-3 sensor requires minimal maintenance to ensure optimal performance.

7. Solució De Problemes

Si el sensor no funciona com s'espera, tingueu en compte els problemes i solucions habituals següents:

ProblemaCausa possibleSolució
Lights do not turn ON with occupancy.No power to sensor; Incorrect wiring; Sensor malfunction.Check power supply and connections; Verify wiring against diagram; Contact support if issue persists.
Lights remain ON or turn OFF too quickly.Incorrect time delay setting; Obstructions blocking detection; Sensor sensitivity issue.Adjust time delay setting; Remove obstructions; Ensure sensor is properly positioned.
False detections (lights turn ON without occupancy).Air currents (HVAC vents); Vibrations; Sensor too sensitive.Relocate sensor away from air currents; Check for sources of vibration; Consult advanced settings if available.

If troubleshooting steps do not resolve the issue, contact Watt Stopper technical support.

8. Especificacions

CaracterísticaDetall
Número de modelUT-305-3
MarcaWatt Stopper
TecnologiaUltrasonic (40kHz)
Àrea de cobertura2000 sq ft (360-degree)
Font d'alimentació24 VDC (Corded Electric)
Tipus de muntatgeMuntatge al sostre
Retard de tempsFixed: 5, 10, 15, 20, 30 minutes
SortidaIsolated Relay for Lighting Load
Dimensions (D x H)4.5 polzades x 1.02 polzades
Pes6.6 unces
ColorBlanc
Dispositius compatiblesBAS, HVAC, Lighting Controls
UPC754182915194

9. Garantia i Suport

For warranty information, please refer to the documentation included with your purchase or visit the official Watt Stopper weblloc. Els termes i condicions de la garantia poden variar.

For technical support, product inquiries, or service, please contact Watt Stopper directly through their official customer support channels. Contact information can typically be found on their weblloc o embalatge del producte.

Documents relacionats - UT-305-3

Preview UW-100-24 Ultrasonic Low Voltage Wall Switch Occupancy Sensor Installation Instructions
Installation instructions and specifications for the Watt Stopper UW-100-24 Ultrasonic Low Voltage Wall Switch Occupancy Sensor. Covers unit description, operation, adjustments, troubleshooting, and ordering information.
Preview Watt Stopper LMDC-100 Occupancy Sensor Quick Start Guide & Installation
Quick start guide for the Watt Stopper LMDC-100 Digital Lighting Management Dual Technology Ceiling Mount Occupancy Sensor. Includes installation, specifications, coverage, and troubleshooting.
Preview Manual d'instal·lació i funcionament del sensor de presència de tecnologia dual Wattstopper DT-205
Guia completa per a la instal·lació, el cablejat, l'ajust i la resolució de problemes del Wattstopper DT-205 Dual Technology Low Voltage Sensor de presència. Compta amb detecció PIR i ultrasònica per a un control eficient de la il·luminació.
Preview Wattstopper DSW Series Dual Technology Wall Switch Occupancy Sensor Installation Guide
Comprehensive installation instructions, specifications, operating modes, and troubleshooting for the Wattstopper DSW Series Dual Technology Multi-Way Wall Switch Occupancy Sensors (DSW-301, DSW-302). Covers features like PIR and ultrasonic detection, manual/auto ON modes, time delays, and multi-way wiring.
Preview Wattstopper LMDC-100 Dual Technology Ceiling Mount Occupancy Sensor
Detailed specifications and features of the Wattstopper LMDC-100, a dual-technology ceiling mount occupancy sensor for energy-efficient lighting and plug load control. Includes operation, applications, mounting, wiring, and ordering information.
Preview Wattstopper WS-250 Passive Infrared Wall Switch Occupancy Sensor Installation and Operation Guide
Comprehensive guide for installing, operating, and troubleshooting the Wattstopper WS-250 Passive Infrared Wall Switch Occupancy Sensor. Covers specifications, wiring, adjustments, and coverage patterns for efficient lighting control.