Introducció
This manual provides instructions for the proper replacement of the Eureka AS-2000 Series Upright Vacuum Long Life Belts (Part No. 83797). These belts are designed for specific Eureka AS-2000 series upright vacuum cleaner models to ensure optimal brush roll performance and cleaning efficiency. Please read all instructions carefully before proceeding with installation.
Informació de seguretat
- Always unplug the vacuum cleaner from the electrical outlet before performing any maintenance or replacement procedures. Failure to do so can result in electric shock or injury.
- Allow the vacuum cleaner to cool down if it has been recently used, as some components may be warm.
- Wear appropriate personal protective equipment, such as gloves, to protect your hands from sharp edges or debris.
- Keep small children and pets away from the work area during maintenance.
- Use only genuine Eureka replacement parts to ensure compatibility and maintain product performance.
Belt Replacement (Setup & Installation)
Follow these steps to replace the drive belt on your Eureka AS-2000 Series upright vacuum cleaner.
- Prepara el buit: Unplug the vacuum cleaner from the power outlet. Lay the vacuum cleaner flat on its front side, exposing the underside of the brush roll housing.
- Remove the Bottom Plate: Locate the screws holding the bottom plate (also known as the sole plate or brush roll cover) in place. Use a screwdriver to remove these screws and carefully lift off the bottom plate. Set the screws and plate aside in a safe place.
- Remove the Brush Roll: Gently lift the brush roll out of its housing. The old belt will likely be wrapped around the brush roll or the motor shaft.
- Treure el cinturó vell: Carefully remove the old, broken, or stretched belt from both the brush roll and the motor shaft. Dispose of the old belt properly.
- Instal·leu el cinturó nou: Take one of the new Eureka AS-2000 Series Long Life Belts (Part No. 83797). First, loop the new belt around the motor shaft. Then, stretch the belt and loop it around the brush roll. Ensure the belt is centered on both the motor shaft and the brush roll.
- Reinstall the Brush Roll: Place the brush roll back into its housing, ensuring that the ends of the brush roll fit correctly into their designated slots. Rotate the brush roll manually a few times to confirm the belt is properly seated and moves freely.
- Reattach the Bottom Plate: Position the bottom plate back onto the vacuum cleaner, aligning it with the screw holes. Secure it with the screws removed in Step 2. Do not overtighten the screws.
- Test the Vacuum: Stand the vacuum upright, plug it into a power outlet, and turn it on briefly to ensure the brush roll spins correctly and the new belt is functioning as expected.

Image: Two black replacement belts for Eureka AS-2000 Series upright vacuum cleaners. These belts are essential for the brush roll to function.
Comprovació posterior a la instal·lació
After replacing the belt, perform the following checks:
- Brush Roll Spin: With the vacuum upright and plugged in, turn it on. Observe the brush roll. It should spin freely and consistently.
- Suction Test: Test the vacuum on a clean floor and then on a carpeted area to ensure proper suction and debris pickup.
- Sorolls inusuals: Listen for any unusual noises, grinding, or burning smells, which could indicate improper installation or a faulty component. If any are detected, immediately unplug the vacuum and re-check the installation.
Manteniment
Regular maintenance helps extend the life of your vacuum and its components, including the drive belt.
- Inspect Belts Regularly: Periodically check the belt for signs of wear, cracking, stretching, or fraying. Replace the belt if any damage is observed.
- Rotlle de raspall net: Frequently remove hair, threads, and other debris wrapped around the brush roll. Excessive build-up can strain the belt and motor, leading to premature belt failure.
- Eviteu les obstruccions: Be careful not to vacuum up large objects, socks, or other items that can jam the brush roll, causing the belt to break or stretch.
- Emmagatzema correctament: Store your vacuum in a clean, dry place to prevent material degradation of the belt.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El rotllo de pinzell no gira | Broken or stretched belt; brush roll jammed with debris. | Replace the belt (refer to "Belt Replacement" section); clean brush roll thoroughly. |
| Vacuum has poor suction | Worn or slipping belt; clogged filters or hose. | Replace the belt; check and clean/replace filters and clear any hose blockages. |
| Burning smell from vacuum | Belt slipping or brush roll jammed. | Immediately unplug the vacuum. Inspect and replace the belt if worn. Clear any brush roll obstructions. |
Especificacions
- Marca: Eureka
- Número de peça: 83797
- Dispositius compatibles: Eureka AS-2000 Series Upright Vacuum Cleaners
- Estil de cinturó: Cinturó Pla
- Item Dimensions (each belt): Approximately 3.8"L x 3.3"W x 0.6"H (when laid flat)
- Nombre de peces: 2 (per paquet)
- Fabricant: ELECTROLUX FLOOR CARE COMPANY
Informació de la garantia
For specific warranty details regarding your Eureka AS-2000 Series Upright Vacuum or its replacement parts, please refer to the original vacuum cleaner's user manual or visit the official Eureka website. Replacement belts are typically considered wear-and-tear items and may have limited or no warranty coverage.
Atenció al client
If you encounter any issues not covered in this manual or require further assistance, please contact Eureka customer support. You can usually find contact information on the official Eureka website or within your vacuum cleaner's original documentation.
Assistència en línia: Visit Eureka Support Weblloc