Introducció
Welcome to the user manual for the Rigol DS1054Z Digital Oscilloscope. This document provides essential information for the safe and effective use of your new instrument. The DS1054Z is a versatile 4-channel, 50 MHz digital oscilloscope designed for precise waveform analysis and measurement in various electronic applications.
Informació de seguretat
Please read all safety instructions carefully before operating the device to prevent injury or damage to the instrument.
- Font d'alimentació: Assegureu-vos que l'oscil·loscopi estigui connectat a una font d'alimentació amb el volum correctetage and frequency as specified on the device.
- Posada a terra: Always use a properly grounded power cord to prevent electric shock.
- Ventilació: No bloquegeu les obertures de ventilació. Assegureu-vos que hi hagi un flux d'aire adequat al voltant de l'instrument per evitar el sobreescalfament.
- Medi ambient: Operate the oscilloscope in a dry, clean environment, away from direct sunlight, high temperatures, humidity, and strong electromagnetic fields.
- Exposició líquida: Avoid exposing the instrument to liquids. If liquid enters the device, disconnect power immediately and have it inspected by qualified service personnel.
- Manteniment: Demaneu totes les tasques de manteniment a personal de servei qualificat. No intenteu obrir ni reparar l'instrument vosaltres mateixos.
Contingut del paquet
Verifiqueu que tots els elements que s'enumeren a continuació s'inclouen al vostre paquet:
- Rigol DS1054Z Digital Oscilloscope
- 4 x Passive Probes (RP2200)
- Cable d'alimentació
- Cable USB
- Certificat de calibratge
- Quick Guide (Printed)

Image: Rigol DS1054Z Oscilloscope with its standard accessories, including four probes, power cord, and documentation.
Producte acabatview
Panell frontal

Imatge: Frontal view of the Rigol DS1054Z, showing the large display, channel inputs, and control buttons.
The front panel features a large 7-inch WVGA (800x480) TFT display for clear waveform visualization. Key controls include:
- Channel Inputs (CH1-CH4): BNC connectors for connecting probes.
- Controls verticals: Knobs and buttons for adjusting vertical scale (Volts/Div) and position for each channel.
- Controls horitzontals: Knobs for adjusting horizontal scale (Sec/Div) and position.
- Controls de disparador: Buttons and knobs for setting trigger level, mode, and source.
- Botons de funció: Dedicated buttons for Measure, Acquire, Storage, Cursor, Display, Utility, Help, and Menu navigation.
- Port d'amfitrió USB: Located on the front for connecting USB storage devices.
Panell posterior

Imatge: Part posterior view of the Rigol DS1054Z, showing power input, LAN, USB, and auxiliary ports. The serial number DS1ZA233608157 is visible.
The rear panel provides essential connectivity options:
- Entrada d'alimentació: Per connectar el cable d'alimentació de CA.
- Port LAN: Per a la connectivitat de xarxa i el control remot.
- USB Device Port: Per connectar-se a un ordinador.
- Aux (TrigOut / PassFail) Port: An auxiliary output for trigger signals or Pass/Fail testing.
Configuració
Connexió d'alimentació
- Ensure the oscilloscope is turned off.
- Connect the provided power cord to the power input on the rear panel of the oscilloscope.
- Connecteu l'altre extrem del cable d'alimentació a una presa de corrent de CA amb connexió a terra.
Probe Connection and Compensation
- Connect the probe to one of the BNC input channels (CH1-CH4) on the front panel.
- Attach the probe clip to the probe compensation test point (usually a square wave output) on the front panel.
- Turn on the oscilloscope.
- Adjust the probe compensation using a small screwdriver on the probe body until a flat-top square wave is displayed on the screen. This ensures accurate measurements.

Image: The Rigol DS1054Z in an operational setup, demonstrating probe connection and signal acquisition.
Instruccions de funcionament
Mides bàsiques
The DS1054Z offers a wide range of measurement capabilities:
- Selecció de canals: Use the CH1-CH4 buttons to enable or disable channels.
- Vertical Scale: Adjust the Volts/Div knob to change the vertical sensitivity.
- Horizontal Scale: Adjust the Sec/Div knob to change the time base.
- Configuració automàtica: Premeu el botó AUTO button for automatic setup of vertical, horizontal, and trigger systems.
- Measure Function: Premeu el botó Mesura button to display automatic measurements such as frequency, period, peak-to-peak voltage, i més.
- Funcions matemàtiques: Utilitzeu el MATEMÀTIQUES button for waveform operations like addition, subtraction, multiplication, division, FFT, and integration.

Multiple waveform display.

Single pulse waveform analysis.

Rising and falling edge signals.

Decoded serial data display.

Amplitude modulated waveform.

Complex multi-channel signal.

Lissajous figures for phase analysis.
Activació
Triggering is crucial for stable waveform display. Use the trigger controls to set the trigger type (Edge, Pulse, Slope, Video, etc.), source (CH1-CH4, AC Line, External), and level. The DS1054Z supports advanced triggering options to capture specific events.
Waveform Display and Analysis
The UltraVision technology provides a deeper memory (12 Mpts, upgradable to 24 Mpts) and a high waveform capture rate (up to 30,000 wfms/s), allowing for the capture of transient events and detailed signal analysis. The multi-level intensity grading display helps visualize signal variations over time.
Manteniment
- Neteja: Use a soft, dry cloth to clean the exterior of the oscilloscope. For stubborn dirt, a slightly damp cloth with mild detergent can be used. Do not use abrasive cleaners or solvents.
- Emmagatzematge: Store the oscilloscope in a cool, dry place, away from direct sunlight and extreme temperatures. When not in use for extended periods, disconnect the power cord.
- Calibració: For optimal performance, periodic calibration by qualified service personnel is recommended.
Resolució de problemes
If you encounter issues with your Rigol DS1054Z, refer to the table below for common problems and solutions.
| Problema | Causa possible | Solució |
|---|---|---|
| Sense pantalla després de l’encesa | Power cord not connected; Power switch off; Fuse blown. | Check power cord connection; Ensure power switch is on; Contact service for fuse replacement. |
| No es mostra cap forma d'ona | Probe not connected; Channel disabled; Vertical scale too high/low; Trigger not set correctly. | Connect probe; Enable channel; Adjust Volts/Div; Adjust trigger level/mode. |
| Unstable waveform | Incorrect trigger settings; Probe compensation incorrect. | Adjust trigger level/mode/source; Perform probe compensation. |
| Soroll excessiu del ventilador | Normal operation; Dust accumulation. | Ensure proper ventilation; Clean dust from vents (if accessible and safe). If persistent or unusual, contact support. |
Especificacions
Key technical specifications for the Rigol DS1054Z Digital Oscilloscope:
| Característica | Especificació |
|---|---|
| Ample de banda | 50 MHz |
| Canals | 4 |
| S en temps realampli Rate | 1 GSa/s (single channel) |
| Profunditat de memòria | 12 Mpts (upgradable to 24 Mpts) |
| Waveform Capture Rate | Up to 30,000 wfms/s |
| Mostra | 7-inch WVGA (800x480) TFT |
| Connectivitat | USB Host, USB Device, LAN, Aux (TrigOut / PassFail) |
| Dimensions (L x A x A) | 13 x 7 x 5 polzades |
| Pes | 6.6 lliures |
| Número de model | DS1054Z |
Informació de la garantia
The Rigol DS1054Z Digital Oscilloscope comes with a 3 ANYS warranty. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the documentation provided with your product or visit the official Rigol weblloc.
Suport
For technical support, product inquiries, or service requests, please contact Rigol customer support through their official channels. You can find more information and resources on the Rigol Official Store on Amazon o la seva empresa weblloc.