The Keyence IV-M30 is an intelligent monitor designed for industrial applications, featuring a 3.5-inch TFT color LCD with QVGA resolution (320 x 240 dots). It includes a white LED backlight and supports USB memory for data transfer. The monitor operates on a 24V DC input voltage with a maximum current of 0.2 Amp and is housed in an Enclosure Type 1.

Figure 1: Keyence IV-M30 Intelligent Monitor in its original packaging, showing the product box with Keyence branding and model number IV-M30.
Informació de seguretat
Always read and understand all safety precautions before operating the IV-M30 monitor. Failure to follow these instructions may result in injury or damage to the equipment.
- Font d'alimentació: Ensure the power supply is 24V DC and does not exceed 0.2 Amp corrent màxima.
- Medi ambient: Operate the monitor within specified environmental conditions to prevent malfunction.
- Instal·lació: La instal·lació ha de ser realitzada per personal qualificat d'acord amb les normes elèctriques locals.
- Manteniment: Desconnecteu l'alimentació abans de realitzar qualsevol manteniment o neteja.
Contingut del paquet
Verify that all items listed below are present in the package upon unboxing.

Figure 2: Contents of the Keyence IV-M30 package, including the monitor unit, instruction manuals, and a connecting cable (OP-87444).
- Keyence IV-M30 Intelligent Monitor Unit
- Manual(s) d'instruccions
- Connecting Cable (e.g., OP-87444, as seen in image)
Configuració
1. Instal·lació física
Mount the IV-M30 monitor securely in the desired location. Ensure adequate ventilation around the unit.

Figura 3: Primer pla view of the Keyence IV-M30 Intelligent Monitor and its accompanying cable (OP-87444), ready for connection.
2. Connexions elèctriques
Connect the 4-pin connector to the monitor. Ensure the 24V DC power supply is connected correctly to the designated terminals. Refer to the wiring diagram in the included instruction manual for precise connections.
The monitor requires a 24V DC input voltage and draws a maximum of 0.2 Amp. Incorrect wiring can damage the unit.

Figura 4: posterior view of the Keyence IV-M30 Intelligent Monitor, highlighting the connection ports and product labels including model number and power requirements.
3. Engegada inicial
Once all connections are secure, apply power to the unit. The monitor should power on and display the initial boot screen.
Instruccions de funcionament
Pantalla i interfície
The IV-M30 features a 3.5-inch TFT color LCD with a touchscreen interface for intuitive operation. Navigation is primarily done through touch gestures.

Figure 5: Close-up of the Keyence IV-M30 Intelligent Monitor's screen and control buttons (PWR, SENSOR), showing the Keyence logo.
Navegació bàsica
- Pantalla tàctil: Use light touches to select options and navigate menus.
- Botó PWR: Located near the screen, typically used for power on/off or standby.
- Botó SENSOR: Used for specific sensor-related functions, as detailed in the full product manual.
USB Memory Functionality
The monitor supports USB memory for data logging, configuration backup, or firmware updates. Insert a compatible USB drive into the designated port (if available, not explicitly visible in images but mentioned in description).
Manteniment
Neteja
To clean the monitor's screen and casing, use a soft, dry cloth. For stubborn marks, a slightly damp cloth with a mild, non-abrasive cleaner can be used. Avoid excessive moisture and harsh chemicals.
Actualitzacions de firmware
Periodically check the Keyence official website for available firmware updates. Updates can improve performance, add features, or resolve issues. Follow the instructions provided with the firmware package for safe installation, typically involving a USB memory device.
Resolució de problemes
| Problema | Causa possible | Solució |
|---|---|---|
| El monitor no s'encén. | No power supply; Incorrect wiring; Faulty power supply. | Verify 24V DC power connection; Check wiring according to manual; Test power supply. |
| La pantalla està en blanc o parpelleja. | Loose cable connection; Software issue; Hardware malfunction. | Ensure all cables are securely connected; Restart the monitor; Contact Keyence support if problem persists. |
| La pantalla tàctil no respon. | Calibration needed; Software glitch; Physical damage. | Attempt touchscreen recalibration (refer to full manual); Restart the monitor; Inspect for physical damage. |
Especificacions
- Model: IV-M30
- Visualització: LCD color TFT de 3.5 polzades
- Resolució: 320 x 240 dots (QVGA)
- Il·luminació de fons: LED blanc
- Suport de memòria: Memòria USB
- Connector: 4 pins
- Entrada Voltage: 24V DC
- Corrent d'entrada: 0.2 Amp Màx
- Tipus de tancament: 1
- Dimensions del producte: 12 x 6 x 3 polzades
- Pes: 1.41 lliures
Garantia i Suport
Informació de la garantia
For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Keyence weblloc web. Conserveu el comprovant de compra per a reclamacions de garantia.
Suport tècnic
If you encounter issues not covered in this manual or require further assistance, please contact Keyence technical support. Contact information can typically be found on the Keyence official weblloc o a la documentació del producte.
Nota: Always provide your product model number (IV-M30) and a detailed description of the issue when contacting support.