AEM 30-0300

Manual d'usuari del controlador de sensor AFR UEGO de banda ampla de la sèrie X AEM 30-0300

1. Introducció

This manual provides comprehensive instructions for the installation, operation, and maintenance of the AEM 30-0300 X-Series Wideband UEGO Air/Fuel Ratio (AFR) Sensor Controller Gauge. The AEM X-Series Wideband UEGO gauge utilizes advanced X-Digital technology to deliver fast and accurate air/fuel ratio readings, crucial for optimal engine tuning and monitoring.

2. Informació de seguretat

WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov.

Always ensure proper ventilation when working on vehicles. Disconnect the vehicle's battery before performing any electrical work. Incorrect installation or use can lead to vehicle damage or personal injury. If you are unsure about any installation steps, consult a qualified automotive technician.

3. Què hi ha a la caixa

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge package includes the following components:

Contents of AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge kit

Image 3.1: All components included with the AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge. This includes the gauge, wideband sensor, various wiring harnesses, and mounting accessories.

4. Característiques clau

The AEM 30-0300 X-Series Wideband UEGO AFR Sensor Controller Gauge offers several advanced features:

5. Configuració i instal·lació

Proper installation is critical for the accurate and reliable operation of your AEM X-Series Wideband UEGO Gauge. It is recommended that installation be performed by a qualified professional.

5.1 Instal·lació del sensor

The wideband UEGO sensor must be installed in the exhaust system. For optimal performance, install the sensor at least 18 inches downstream from the exhaust port, before any catalytic converters. Ensure the sensor bung is welded securely and the sensor is oriented to prevent condensation buildup.

5.2 Gauge Mounting

Mount the gauge in a location that is easily visible to the driver and protected from direct moisture and extreme heat. The gauge fits into a standard 52mm (2-1/16 inch) opening.

lateral view of AEM 30-0300 gauge showing mounting studs

Imatge 5.1: Lateral view of the AEM 30-0300 gauge, illustrating its compact design and the rear mounting studs for secure installation into a dashboard or gauge pod.

5.3 Connexions de cablejat

The gauge requires power, ground, and connections to the wideband sensor. Additionally, there are output wires for data logging and feedback control. Refer to the official AEM user guide PDF for detailed wiring diagrams specific to your application.

AEM 30-0300 wideband sensor and wiring harnesses

Image 5.2: The wideband sensor and associated wiring harnesses. Proper connection of these components is essential for accurate AFR readings and data output.

For detailed wiring diagrams and installation steps, please refer to the official AEM User Guide PDF linked in Section 9.

6. Instruccions de funcionament

Once properly installed and powered, the AEM X-Series Wideband UEGO Gauge will display the current Air/Fuel Ratio (AFR) or Lambda value. The gauge automatically calibrates the sensor upon startup.

6.1 Lectura de la pantalla

The large seven-segment display shows the numerical AFR value. The outer LED sweep provides a quick visual reference of the AFR range. The gauge typically displays AFR values from 8:1 (rich) to 20:1 (lean).

Close-up of AEM 30-0300 gauge display showing AFR reading

Imatge 6.1: Primer pla view of the AEM 30-0300 gauge display, showing a typical AFR reading and the surrounding LED sweep for quick visual interpretation.

6.2 Mode and Select Buttons

The gauge features 'MODE' and 'SEL' (Select) buttons, typically located on the front or side of the unit. These buttons allow you to cycle through display modes (e.g., AFR, Lambda) or perform specific functions as outlined in the detailed user manual.

7. Manteniment

The AEM X-Series Wideband UEGO Gauge and sensor are designed for durability, but proper maintenance ensures longevity and accuracy.

8. Solució De Problemes

If you encounter issues with your AEM X-Series Wideband UEGO Gauge, consider the following common troubleshooting steps:

For more detailed troubleshooting guides and error codes, refer to the complete AEM User Guide PDF.

9. Especificacions

EspecificacióValor
Número de model30-0300
Tipus d'indicadorWideband UEGO AFR Sensor Controller Gauge
TecnologiaX-Digital
MostraDigital 7-segment with LED sweep
Senyals de sortida0-5v Analog, RS232 Serial Port, AEMnet (CANbus)
Calibre Diàmetre52mm (2-1/16 inch)
Pes de l'article0.01 ounces (Controller/Gauge only)
FabricantAEM

10. Garantia i Suport

For warranty information, please refer to the documentation provided with your product or visit the official AEM website. AEM provides technical support for its products. If you require assistance with installation, operation, or troubleshooting beyond the scope of this manual, please contact AEM customer service directly.

11. Recursos addicionals

For the most detailed and up-to-date installation instructions, wiring diagrams, and advanced features, please download the official AEM User Guide PDF:

Descarrega la Guia d'usuari oficial (PDF)

Documents relacionats - 30-0300

Preview Instruccions d'instal·lació d'AEM EMS 30-6300 per a Mitsubishi Eclipse, Talon, Laser, Galant VR4
Comprehensive installation guide for the AEM Engine Management System (EMS) P/N 30-6300, designed for 1990-1994 Mitsubishi Eclipse Turbo, Talon Tsi, Dodge/Eagle Talon Tsi, Mitsubishi Eclipse RS, and Mitsubishi Galant VR4. Covers software installation, ECU removal/installation, calibration, tuning, troubleshooting, sensor configuration, wiring, and pinout diagrams.
Preview Manual d'instal·lació de l'arnès de l'adaptador PnP AEM 30-3511 Infinity per a Mitsubishi EVO 8 2003-2005
Manual d'instal·lació complet per a l'arnès adaptador AEM 30-3511 Infinity Plug and Play per a models Mitsubishi EVO 8 2003-2005. Cobreix més deview, kit contents, options, important application notes, installation steps, setup wizard, and pinout information.
Preview Instruccions d'instal·lació d'AEM 21-8128DC per a Ford F150 EcoBoost del 2015
Guia d'instal·lació detallada per al sistema d'admissió d'aire de rendiment AEM 21-8128DC per als models Ford F150 EcoBoost 2.7L i 3.5L Turbo del 2015. Inclou una llista de peces i instruccions pas a pas.
Preview Instruccions d'instal·lació de la presa d'aire fred AEM 21-813C per a Chevrolet Malibu 1.5T
Guia d'instal·lació detallada per al sistema d'admissió d'aire fred Dryflow AEM 21-813C en models Chevrolet Malibu 2016-2018 amb motor 1.5T. Inclou una llista de peces, les eines necessàries i informació sobre la garantia.
Preview Suplement d'instal·lació i funcionament del tauler de control AEM G13116RNS
Aquest document proporciona detalls d'instal·lació i funcionament del panell de control d'una línia AEM G13116RNS, amb connectivitat Bluetooth. Cobreix la descripció del producte, les aprovacions reglamentàries, les notes d'instal·lació i la resolució de problemes per a sistemes d'àudio d'aviació.
Preview Instruccions d'instal·lació del sistema d'admissió de flux sec AEM 21-8017
Instruccions d'instal·lació detallades per al sistema d'admissió de flux sec AEM 21-8017 per a models Chevrolet Silverado i GMC Sierra 2004-2005 amb motor DSL V8-6.6L, incloent-hi una llista de peces i informació sobre la garantia.