1. Introducció
This manual provides essential information for the safe and effective operation of your OWON SDS6062 Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. The SDS6062 is a 2-channel oscilloscope featuring a 60 MHz bandwidth, 500 MS/s sample rate, and a 10M record length, designed for precise electrical signal analysis.
2. Informació de seguretat
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or any connected products. Read these instructions carefully before operation.
- Font d'alimentació: Use only the power adapter supplied with the instrument. Ensure the voltage coincideix amb la vostra font d'alimentació local.
- Posada a terra: The oscilloscope must be properly grounded to prevent electric shock.
- Seguretat de la sonda: Do not connect the probe ground lead to a point where a voltage greater than 30V RMS or 42.4V peak is present.
- Medi ambient: Operate the device in a well-ventilated area, away from moisture, dust, and direct sunlight. Avoid operating in explosive atmospheres.
- Manteniment: Demaneu totes les tasques de manteniment a personal de servei qualificat. No intenteu reparar la unitat vosaltres mateixos.
3. Contingut del paquet
Verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier.
- OWON SDS6062 Digital Storage Oscilloscope Unit
- 2 x Oscilloscope Probes
- 1 x cable d'alimentació
- 1 x Probe Adjust Pen
- 1 x cable de dades USB
- 1 x CD de programari
- 1 x Manual d'usuari (aquest document)
4. Producte acabatview
The OWON SDS6062 is a compact and powerful digital storage oscilloscope. It features an 8-inch (800x600) color TFT-LCD screen for clear waveform display and an intuitive control panel for easy operation. Key features include its 60 MHz bandwidth, 500 MS/s real-time sample rate, and 10M record length, making it suitable for a wide range of applications.

Figura 4.1: Frontal view of the OWON SDS6062 Digital Storage Oscilloscope, showing the display, control knobs, and function buttons.
4.1 Controls del panell frontal
The front panel includes the main display, vertical controls (VOLTS/DIV, position), horizontal controls (SEC/DIV, position), trigger controls, and various function buttons for menu navigation, measurement, and utility settings.
4.2 Connexions del panell posterior
The rear panel provides connectivity options including the power input, USB host and device ports, LAN port for network connectivity, and a VGA port for external display output.
5. Configuració
Follow these steps to set up your OWON SDS6062 oscilloscope for initial use.
5.1 Connexió de potència
- Ensure the oscilloscope is turned off.
- Connect the supplied power cord to the power input on the rear panel of the oscilloscope.
- Connecteu l'altre extrem del cable d'alimentació a una presa de corrent de CA amb connexió a terra.
5.2 Connexió de sondes
- Align the BNC connector of the probe with the CH1 or CH2 input on the front panel.
- Push and twist the connector clockwise until it locks into place.
- Attach the probe ground clip to the ground terminal of the circuit under test.
- Set the probe attenuation switch (e.g., 1X or 10X) to match the setting on the oscilloscope's input channel menu.
5.3 Engegada inicial
- Premeu el botó d'encesa situat al tauler frontal.
- The oscilloscope will perform a self-test and display the startup screen.
- After startup, it is recommended to perform a probe compensation adjustment (refer to Section 7.3).
6. Funcionament de l'oscil·loscopi
This section covers basic operation and common functions of the SDS6062.
6.1 Mesures bàsiques
To display a signal:
- Connect a signal source to CH1 or CH2 using a probe.
- Premeu el botó AUTOSET button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings to display a stable waveform.
- Ajusteu el VOLTS/DIV knob to change the vertical scale (voltage per divisió).
- Ajusteu el SEC/DIV knob to change the horizontal scale (time per division).
- Use the vertical and horizontal POSICIÓ knobs to move the waveform on the screen.
6.2 Trigger System
The trigger system stabilizes repetitive waveforms and captures single-shot events.
- Nivell d'activació: Utilitza el TRIGGER LEVEL botó per ajustar el volumtage level at which the trigger occurs.
- Mode de commutació: Access the trigger menu to select modes like Edge, Pulse, Video, or Slope.
- Font del disparador: Select the input channel (CH1, CH2, EXT, AC Line) that will be used for triggering.
6.3 Funcions de mesura
The SDS6062 offers various automatic measurement functions.
- Premeu el botó MESURA button to display the measurement menu.
- Select desired measurements such as Vpp, Vmax, Vmin, Freq, Period, Rise Time, etc.
6.4 Connectivity (LAN and VGA)
- LAN: Connect an Ethernet cable to the LAN port on the rear panel to connect the oscilloscope to a network. This allows for remote control and data transfer using compatible software.
- VGA: Use the VGA port to connect an external monitor or projector for larger display of waveforms, useful for presentations or collaborative work.
7. Manteniment
Un manteniment adequat garanteix la longevitat i la precisió del vostre oscil·loscopi.
7.1 Neteja
Clean the instrument regularly with a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the casing o pantalla. Assegureu-vos que el dispositiu estigui apagat i desendollat abans de netejar-lo.
7.2 Emmagatzematge
When not in use, store the oscilloscope in a dry, dust-free environment, away from extreme temperatures and direct sunlight. Use the original packaging or a suitable carrying case for protection during transport.
7.3 Probe Compensation Adjustment
Probe compensation should be adjusted to match the oscilloscope's input characteristics. This ensures accurate measurements.
- Connect the probe to CH1 and attach the probe tip to the probe compensation output (usually a square wave test point on the front panel).
- Attach the probe ground clip to the ground terminal.
- Premeu AUTOSET.
- Use the supplied probe adjust pen to turn the trimmer screw on the probe until the square wave displayed on the screen has flat top and bottom edges (no overshoot or undershoot).
8. Solució De Problemes
Aquesta secció ofereix solucions a problemes comuns que podeu trobar.
- Sense pantalla: Check power connection, ensure the power button is pressed. Adjust screen brightness if necessary.
- No Waveform: Verify probe connection to the input channel and the circuit under test. Ensure the signal source is active. Press AUTOSET. Check vertical and horizontal scale settings.
- Forma d'ona inestable: Adjust the trigger level. Check trigger mode and source settings. Ensure the signal is within the oscilloscope's bandwidth.
- Mesures inexactes: Perform probe compensation adjustment (Section 7.3). Ensure probe attenuation settings match the oscilloscope.
- El dispositiu no respon: Try restarting the oscilloscope. If the issue persists, contact technical support.
9. Especificacions
Technical specifications for the OWON SDS6062 Digital Storage Oscilloscope.
| Paràmetre | Especificació |
|---|---|
| Número de model | SDS6062 |
| Ample de banda | 60 MHz |
| Canals | 2 + 1 (External Trigger) |
| Sample Rate (Real-time) | 500 MS/s |
| Durada del registre | 10M points |
| Mostra | 8-inch Color TFT-LCD (800x600) |
| Interfície | USB Host, USB Device, LAN, VGA |
| AutoScale Function | Sí |
| Fabricant | OWON |
10. Garantia i Suport
OWON products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official OWON website. For technical support, troubleshooting assistance, or service inquiries, please contact your local OWON distributor or the OWON customer service department. Keep your purchase receipt as proof of purchase for warranty claims.