LUX P711-010

Manual d'usuari del termòstat domèstic Lux Pro P711

Model: P711-010 | 7-Day Programmable: 1 Heat & 1 Cool Stage

1. Producte acabatview

The Lux Pro Home Thermostat Model P711-010 is a versatile 7-day programmable thermostat designed for 1 heat and 1 cool stage HVAC systems. It offers flexible temperature control options, including 7-day, 5/2-day programming, or non-programmable settings. Key features include an easy-view backlight, keypad lock for security, and customizable display options for Fahrenheit or Celsius.

This thermostat is dual-powered, operating on 2 AA alkaline batteries (included) or a 24-volt system, ensuring reliable performance. It is designed for easy installation and intuitive operation, making it a convenient solution for managing your home's heating and cooling.

Lux Pro P711 Thermostat Front View

Figura 1: Frontal view of the Lux Pro P711 Thermostat, showing the display, fan and system mode switches, and control buttons.

Lux Pro P711 Thermostat Control Panel Diagram

Figure 2: Labeled diagram of the P711 control panel, indicating the LCD Display Screen, Fan Mode Switch, System Mode Switch, SET, NEXT, HOLD buttons, and UP and DOWN buttons.

2. Informació de seguretat

Before installation or operation, please read all instructions carefully. Failure to follow these instructions could result in property damage or personal injury.

  • Desconnecteu sempre l'alimentació del sistema de calefacció/refrigeració al fusible principal o al quadre elèctric abans d'instal·lar o fer el manteniment del termòstat.
  • Assegureu-vos que totes les connexions de cablejat siguin segures i que compleixin els codis elèctrics locals.
  • Do not short (jumper) across the electrical terminals on the thermostat base.
  • This thermostat is designed for low voltage (24V) systems. Do not use with line voltagSistemes electrònics (120V/240V).
  • Mantingueu les piles fora de l'abast dels nens. Desfeu-vos de les piles usades correctament.

3. Instal·lació

3.1. Compatibilitat

The P711 thermostat is compatible with a variety of 24V heating and cooling systems. Refer to the compatibility chart below to ensure your system is supported.

Lux Pro P711 Thermostat System Compatibility Chart

Figure 3: System Compatibility Chart for the P711 Thermostat, detailing compatible and non-compatible HVAC systems.

3.2. Eines i materials necessaris

  • Tornavís de cap Phillips
  • Drill with 3/16” (4.8mm) drill bit (if new holes are needed)
  • Pelafils (si cal)
  • Llapis
  • Nivell (opcional)

3.3. Passos d'instal·lació

  1. Apagueu l'alimentació: Locate the circuit breaker or fuse box that controls your heating and cooling system and turn off the power. Verify the power is off by attempting to turn on your system.
  2. Elimina el termòstat antic: Carefully remove the cover of your old thermostat. Take a picture of the wiring connections before disconnecting any wires. Label each wire with the terminal designation (e.g., R, G, Y, W, C) using the provided wire labels.
  3. Treure la placa de muntatge: Desenrosqueu i traieu la placa de muntatge del termòstat antic de la paret.
  4. Muntar la nova base del termòstat: Separate the front cover of the P711 thermostat from its base. Position the new thermostat base on the wall, feeding the wires through the opening. Mark the mounting holes with a pencil. If drilling new holes, use a 3/16” drill bit and insert the wall anchors. Secure the thermostat base to the wall using the provided screws.
  5. Connecteu el termòstat: Connect the labeled wires to the corresponding terminals on the P711 thermostat base. Refer to the wiring diagrams below for common configurations. Ensure connections are tight.
Wiring Diagram for 3/4 Wires Conventional, Non Heat Pump, 1-Stage Només fresc

Figure 4: Wiring diagram for 3/4 wire conventional, non-heat pump, 1-stage cool only systems. Shows connections for C, G, RH, RC, W, Y, O/B terminals.

Wiring Diagram for 4/5 Wires Conventional, Non Heat Pump, 1-Stage Calor i 1-Stage Cool

Figure 5: Wiring diagram for 4/5 wire conventional, non-heat pump, 1-stage calor i 1-stage cool systems. Shows connections for C, G, RH, RC, W, Y, O/B terminals.

Wiring Diagram for 5/6 Wires Conventional, Non Heat Pump, 1-Heat / 1-Cool, with Two-Transformers

Figure 6: Wiring diagram for 5/6 wire conventional, non-heat pump, 1-heat / 1-cool systems with two transformers. Shows connections for C, G, RH, RC, W, Y, O/B terminals, and the removal of the factory RH-RC jumper wire.

  1. Insereix les piles: If using battery power, insert the 2 AA alkaline batteries into the battery compartment.
  2. Fixeu la coberta del termòstat: Carefully align the thermostat cover with the base and snap it into place.
  3. Restaura l'alimentació: Return to the circuit breaker or fuse box and restore power to your heating and cooling system.

4. Configuració i configuració inicials

4.1. Configuració de l'hora i el dia

Upon initial power-up or after a battery change, the display will show a flashing time and day. Use the SET button to navigate through the time and day settings, and the UP i ABAIX buttons to adjust the values. Press SEGÜENT per confirmar cada configuració.

4.2. Modes de programació

The P711 offers three programming options: 7-day, 5/2-day, or non-programmable. You can select your preferred mode during the initial setup or by accessing the system settings. Refer to the detailed programming instructions in the full manual for specific steps on setting schedules for each day or period.

4.3. Display Options (Fahrenheit/Celsius)

You can switch between Fahrenheit (°F) and Celsius (°C) display modes. This setting is typically found within the advanced setup menu. Consult the full manual for instructions on accessing and changing this option.

4.4. Bloqueig del teclat

The keypad lock feature prevents unauthorized access or accidental changes to your thermostat settings. To activate or deactivate the keypad lock, follow the instructions provided in the comprehensive manual.

5. Funcionament

5.1. Ajust de la temperatura

En el mode de funcionament normal, utilitzeu el UP or ABAIX buttons to adjust the desired temperature setpoint. The new setpoint will be displayed, and the thermostat will adjust the system to reach it.

5.2. Configuració del ventilador

The fan mode switch allows you to select between two settings:

  • AUTOMÀTIC: El ventilador només funciona quan el sistema de calefacció o refrigeració està en funcionament. Aquesta és la configuració més eficient energèticament.
  • ACTIVITAT: El ventilador funciona contínuament, independentment de si el sistema de calefacció o de refrigeració està actiu.

5.3. Mode del sistema

The system mode switch allows you to select the operating mode for your HVAC system:

  • CALOR: The thermostat will control your heating system to maintain the set temperature.
  • DESACTIVAT: Tant els sistemes de calefacció com els de refrigeració estan apagats.
  • GUAI: The thermostat will control your cooling system to maintain the set temperature.

5.4. Funció Hold

El MANTENIM button allows you to temporarily or permanently override the programmed schedule. When activated, the thermostat will maintain the current temperature setpoint until the HOLD function is canceled or a new schedule period begins (for temporary hold).

5.5. Temporary Override

Ajust de la temperatura mitjançant el UP or ABAIX buttons during a programmed period will initiate a temporary override. The thermostat will maintain this new temperature until the next scheduled program period begins.

6. Manteniment

6.1. Substitució de la bateria

The thermostat uses 2 AA alkaline batteries. When the battery indicator appears on the display, replace the batteries promptly to ensure continuous operation. Open the battery compartment, remove old batteries, and insert new ones, observing polarity (+/-). The thermostat has battery-free memory, so programming should not be lost during battery replacement.

6.2. Neteja

Netegeu l'exterior del termòstat amb un drap suau iamp drap. No utilitzeu productes de neteja abrasius ni dissolvents, ja que poden danyar l'acabat o els components interns.

7. Solució De Problemes

If you experience issues with your Lux Pro P711 thermostat, refer to the common troubleshooting steps below. For more complex problems, contact customer support.

ProblemaCausa possibleSolució
La pantalla està en blanc o tènueLow or dead batteries; No 24V power (if wired); Loose connections.Replace batteries. Check circuit breaker for HVAC system. Verify wiring connections are secure.
System (Heat/Cool) does not turn onSystem switch in OFF position; Incorrect wiring; Blown fuse in HVAC system; Temperature setpoint not calling for heat/cool.Ensure system switch is set to HEAT or COOL. Recheck wiring against diagrams. Check HVAC system fuse. Adjust setpoint to be above (for heat) or below (for cool) current room temperature.
El ventilador no funcionaFan switch in AUTO; Incorrect wiring.Set fan switch to ON to test continuous operation. Verify fan wiring (G terminal).
Lectura de temperatura inexactaThermostat exposed to direct sunlight or drafts; Needs calibration.Relocate thermostat if possible. Access user temperature calibration setting (refer to full manual).
Problemes de programacióIncorrect programming steps; Keypad locked.Review programming instructions carefully. Unlock keypad if activated.

8. Especificacions

CaracterísticaEspecificació
MarcaLUX
Nom del modelP711-010
Tipus de controladorPulsador
Característica especialVolum baixtage
ColorBlanc
Tipus de control de temperaturaManual, programable
Tecnologia de connectivitatN/A (Note: Product specifications list Wi-Fi, but this model is typically non-Wi-Fi. Refer to specific product packaging for confirmation.)
Components inclososP711-010 Programmable 7 Day Thermostat, 2 AA LR6 batteries, 2 ST screws, 2 wall anchors, wire labels, instruction manual
Font d'alimentacióBattery Powered (2 AA included), 24 Volts (system power)
Pes de l'article1.6 unces
Voltage24 Volts
MaterialPlàstic
FormaRectangular
Tipus de visualitzacióLCD amb llum de fons
Tipus de controlControl de botons
Tipus de muntatgeMuntatge de paret
EstilProgrammable: 1 heat & 1 cool Stage
Llum de fons
CertificacióUL (Underwriters Laboratories) Low Voltage Certification
Dimensions del producte1.25 x 3.38 x 5.38 polzades
UPC021079147113

9. Garantia i Suport

9.1. Informació de la garantia

The Lux Pro P711 Thermostat typically comes with a 5-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims.

9.2. Atenció al client

For technical assistance, troubleshooting not covered in this manual, or warranty inquiries, please contact LUX customer support. Refer to the contact information provided on the product packaging or the official LUX weblloc (www.luxproducts.com) for the most up-to-date support options.

Documents relacionats - P711-010

Preview Termòstat universal LUX TX700U: Guia d'instal·lació i característiques
Manual i guia d'instal·lació complets per al termòstat universal LUX TX700U, que cobreix la configuració, la programació, el cablejat i el funcionament de diversos sistemes de climatització. Apreneu sobre la compatibilitat del sistema, les precaucions, els passos d'instal·lació, els controls del panell frontal, les opcions de configuració, la programació de la temperatura i les funcions de calefacció d'emergència.
Preview LUX TX9100Ua Smart Temp Universal 7-Day Programmable Thermostat Installation and Operation Manual
Comprehensive installation and operation manual for the LUX TX9100Ua Smart Temp Universal 7-Day Programmable Thermostat. Covers system compatibility, features, installation steps, wiring diagrams, operation, programming, advanced functions, battery replacement, technical assistance, and warranty.
Preview LUX TX100E Programmable Thermostat: Installation and Operating Instructions
Comprehensive installation and operating instructions for the LUX TX100E programmable thermostat, covering system compatibility, features, wiring diagrams, setup, operation, advanced features, and warranty information.
Preview LUX TX9100Ub Smart Temp Universal 7-Day Programmable Thermostat Installation and Operation Manual
Comprehensive guide for installing and operating the LUX TX9100Ub Smart Temp Universal 7-Day Programmable Thermostat. Covers system compatibility, features, wiring diagrams, front panel elements, system configuration, operating instructions, temperature programming, advanced functions, monitors, resets, battery replacement, technical assistance, and warranty information.
Preview Termòstat tàctil universal programable de 7 dies LUX TX9600TSa Smart Temp: instruccions d'instal·lació i funcionament
Aquest manual detalla la instal·lació, el funcionament, les característiques i la resolució de problemes del termòstat tàctil universal programable de 7 dies LUX TX9600TSa Smart Temp, compatible amb sistemes convencionals i de bomba de calor.
Preview LUX TX9600TSa Programmable 7-Day Smart Temp Thermostat Installation & User Manual
Comprehensive installation and user manual for the LUX TX9600TSa programmable 7-day smart temperature thermostat. Covers setup, wiring, features, operation, and troubleshooting for both heat pump and traditional systems.