1. Introducció
The Astralpool EvoLine 15-8.7 KW is an advanced air/water heat pump designed to efficiently heat residential swimming pools up to 80 m³. This unit extends your swimming season by economically extracting heat from the ambient air, providing up to five times the energy consumed. Featuring Wi-Fi control via the AstralPool EVOLine application, digital controls, and robust construction, this heat pump offers reliable and environmentally friendly pool heating. This manual provides essential information for the safe installation, operation, and maintenance of your EvoLine heat pump.
2. Informació de seguretat
Please read all safety instructions carefully before installing, operating, or performing maintenance on the heat pump. Failure to follow these instructions may result in property damage, serious injury, or death.
- Seguretat elèctrica: All electrical work must be performed by a qualified electrician in accordance with local and national electrical codes. Ensure the unit is properly grounded.
- Seguretat de l'aigua: Ensure all plumbing connections are secure to prevent leaks. Do not operate the unit without proper water flow.
- Refrigerant: The unit contains R410A refrigerant. Servicing involving the refrigerant circuit must only be performed by certified technicians.
- Col·locació: No bloquegeu les reixetes d'entrada o sortida d'aire. Mantingueu un espai lliure adequat al voltant de la unitat per a un flux d'aire adequat.
- Nens: Keep children away from the heat pump during operation and maintenance.
- General: Do not attempt to modify the unit. Use only genuine Astralpool replacement parts.
3. Producte acabatview
The Astralpool EvoLine heat pump is designed for optimal performance and durability. Key components include an oversized evaporator, a high-efficiency compressor, an A1 titanium double spiral exchanger, and a waterproof digital control panel.

Figura 1: Astralpool EvoLine 15-8.7 KW Pool Heat Pump. This image shows the exterior of the heat pump unit, typically featuring the air intake and exhaust grilles, the control panel, and the robust ABS casing.
The unit features an ABS/white casing for durability and aesthetic integration. An electric resistance on the lower tray prevents ice formation, ensuring reliable operation even at lower ambient temperatures.
4. Configuració i instal·lació
Proper installation is crucial for the performance and longevity of your heat pump. It is recommended that installation be performed by a qualified professional.
4.1 Col·locació
- Install the heat pump outdoors in a well-ventilated area, away from direct sunlight and heat sources.
- Ensure sufficient clearance (at least 50 cm) around the unit for unrestricted airflow to the evaporator and condenser.
- Place the unit on a solid, level surface capable of supporting its weight (approximately 100 kg).
- Avoid placing the unit near windows or areas where noise might be a concern.
4.2 Connexions de fontaneria
- Connect the heat pump to your pool's filtration system after the filter and before any chemical feeders.
- Use appropriate PVC piping and fittings. Ensure all connections are watertight.
- Install a bypass valve system to allow for isolation of the heat pump for maintenance without interrupting pool circulation.
4.3 Connexions elèctriques
- Electrical wiring must be carried out by a licensed electrician.
- Ensure the power supply matches the specifications of the heat pump (voltage, ampera).
- Install a dedicated circuit breaker and a suitable disconnect switch near the unit.
- La connexió a terra adequada és essencial per a la seguretat.
5. Instruccions de funcionament
Once installed and connected, operating your EvoLine heat pump is straightforward.
5.1 Posada en marxa inicial
- Assegureu-vos que la bomba de la piscina estigui en funcionament i que l'aigua flueixi a través de la bomba de calor.
- Turn on the electrical power to the heat pump at the disconnect switch.
- El tauler de control digital s'il·luminarà.
5.2 Configuració de la temperatura desitjada
- Use the up/down arrows on the digital control panel to set your desired pool water temperature.
- The unit will automatically begin heating or cooling to maintain the set temperature.
5.3 Wi-Fi Control (AstralPool EVOLine App)
- Download the free AstralPool EVOLine application from your device's app store.
- Segueix les instruccions de l'aplicació per connectar la bomba de calor a la xarxa Wi-Fi de casa teva.
- Once connected, you can monitor and control your heat pump remotely, adjust settings, and view estat operatiu.
5.4 Modes de calefacció i refrigeració
The EvoLine heat pump can both heat and cool your pool water, allowing for precise temperature regulation to maintain a constant, comfortable swimming temperature.
5.5 Funció de descongelació
The unit features automatic defrosting via cycle inversion. This function prevents ice buildup on the evaporator coils, ensuring efficient operation even in colder conditions (minimum operating air temperature 0 °C).
6. Manteniment
Un manteniment regular garanteix un rendiment òptim i allarga la vida útil de la bomba de calor.
6.1 Neteja regular
- Mantingueu la zona al voltant de la bomba de calor neta de deixalles, fulles i altres obstacles.
- Periodically clean the evaporator coils with a soft brush or garden hose to remove dirt and dust. Ensure the unit is powered off before cleaning.
- Netegeu l'exterior casing amb anunciamp tela.
6.2 Hivernització
Before the winter season or when temperatures consistently drop below 0 °C, it is recommended to winterize your heat pump:
- Turn off the heat pump and disconnect its electrical power.
- Drain all water from the heat pump's plumbing to prevent freezing damage.
- Cover the unit with a breathable, protective cover to shield it from harsh weather conditions.
6.3 Professional Service
For any issues related to the refrigerant circuit or complex electrical problems, contact a certified HVAC technician or Astralpool authorized service center.
7. Solució De Problemes
This section addresses common issues you might encounter with your heat pump.
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba de calor no s'encén | No power, tripped breaker, faulty wiring. | Check power supply and circuit breaker. Ensure disconnect switch is ON. Contact an electrician if problem persists. |
| Unit running but not heating | Low water flow, dirty evaporator coils, low refrigerant. | Ensure pool pump is running and filter is clean. Clean evaporator coils. Contact service for refrigerant check. |
| Es mostra el codi d'error | Error específic del sistema. | Refer to the AstralPool EVOLine app or contact customer support with the specific error code. |
| Soroll excessiu | Components solts, obstrucció del ventilador, problema del compressor. | Check for loose panels or obstructions. If noise persists or is unusual, contact service. |
For issues not listed or if solutions do not resolve the problem, please contact Astralpool customer support.
8. Especificacions
Technical specifications for the Astralpool EvoLine 15-8.7 KW heat pump:
- Model: EvoLine 15-8.7 KW
- Producte ASIN: B01BNV5R20
- Fabricant: AstralPool
- Pes: Aproximadament 100 quilograms
- Tipus de refrigerant: R410A
- Minimum Operating Air Temperature: 0 °C
- Volum de piscina recomanat: Up to 80 m³ (residential pools)
- CasinMaterial: ABS / Blanc
- Termocambiador: A1 Titanium Double Spiral
- Control: Digital, Wi-Fi enabled via AstralPool EVOLine app
- Defrosting Method: Cycle Inversion
- Característiques: Heat and cold function, waterproof electrical panel, high and low pressure switch, electric resistance on lower tray for ice prevention.
9. Garantia i Suport
Astralpool products are manufactured to high-quality standards and come with a manufacturer's warranty. Specific warranty terms and conditions may vary by region and purchase date. Please refer to your purchase documentation or contact your retailer for detailed warranty information.
For technical assistance, spare parts, or warranty claims, please contact Astralpool customer support or an authorized service center. Ensure you have your product model and ASIN (B01BNV5R20) available when contacting support.