Model: MS-OPS2H-WH

1. Producte acabatview

The Lutron Maestro Occupancy Detection Switch (MS-OPS2H-WH) integrates a standard light switch with a passive infrared (PIR) occupancy sensor. This device is designed to automatically control lighting based on the presence or absence of occupants in a room. The sensor detects the heat signatures of moving individuals within its detection zone, activating or deactivating the connected load (e.g., lights) accordingly.

Lutron MS-OPS2H-WH Occupancy Sensor Switch, front view

Figura 1: Frontal view of the Lutron MS-OPS2H-WH Occupancy Sensor Switch.

2. Informació de seguretat

ADVERTIMENT: Risk of Electric Shock. Improper installation can result in serious injury or death. Always turn off power at the circuit breaker or fuse box before installing or servicing this device. This product must be installed by a qualified electrician in accordance with all local and national electrical codes.

  • No utilitzeu amb càrregues que superin les capacitats especificades.
  • Instal·leu només a l'interior.
  • Assegureu-vos que totes les connexions dels cables estiguin segures i correctament aïllades.
  • Grounding is required for safe operation.

3. Instal·lació (Configuració)

  1. Apagueu l'alimentació: Locate the circuit breaker or fuse that controls the power to the switch location. Turn it OFF. Verify power is off by attempting to turn on the light controlled by the switch.
  2. Elimina l'interruptor existent: Carefully remove the wall plate and unscrew the existing switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
  3. Connecteu el nou interruptor: Connect the wires from the wall box to the Lutron MS-OPS2H-WH switch according to the wiring diagram provided with the product packaging. Typically, this involves connecting the hot (line), load, neutral (if present), and ground wires. Ensure all connections are tight.
  4. Muntar l'interruptor: Introduïu suaument l'interruptor amb cable a la caixa de paret. Fixeu-lo amb els cargols proporcionats.
  5. Fixeu la placa de paret: Install the decorative wall plate over the switch.
  6. Restaura l'alimentació: Torneu a encendre l'alimentació a l'interruptor automàtic o a la caixa de fusibles.

Nota: If you are unsure about any wiring steps, consult a qualified electrician.

4. Funcionament

The MS-OPS2H-WH switch operates in two primary modes: Occupancy Sensing and Vacancy Sensing. The default mode is typically Occupancy Sensing (lights turn ON automatically when motion is detected and OFF when the room is vacant).

  • ON/OFF automàtic: In Occupancy mode, the sensor detects movement and automatically turns the connected lights ON. After a preset time delay with no detected motion, the lights will automatically turn OFF.
  • Manual ON/Automatic OFF: In Vacancy mode, the lights must be turned ON manually by pressing the switch button. They will then turn OFF automatically after a preset time delay with no detected motion.
  • Control manual: You can manually turn the lights ON or OFF at any time by pressing the large paddle switch.

Refer to the detailed instructions included in the product packaging for information on adjusting sensitivity and time-out settings, as these may vary by model revision.

5. Manteniment

The Lutron MS-OPS2H-WH switch requires minimal maintenance.

  • Neteja: To clean the surface of the switch and wall plate, use a soft, damp drap. No utilitzeu netejadors abrasius, dissolvents ni esprais químics, ja que poden danyar l'acabat o els components interns.
  • Obstrucció: Ensure the sensor lens is not obstructed by furniture, decorations, or other objects, as this can impair its ability to detect motion.

6. Solució De Problemes

Problema Causa possible Solució
Lights do not turn ON automatically.
  • L'alimentació està apagada.
  • Cablejat incorrecte.
  • Lent del sensor obstruïda.
  • Switch is in Vacancy mode.
  • Comproveu l'interruptor.
  • Verifiqueu les connexions del cablejat.
  • Clear obstructions from sensor.
  • Change operating mode to Occupancy.
Els llums s'apaguen massa ràpid o massa lentament.
  • Time-out setting is incorrect.
  • Sensor sensitivity is too low/high.
  • Adjust the time-out setting.
  • Adjust sensor sensitivity.
Lights turn ON/OFF unexpectedly.
  • Drafts or heat sources in detection zone.
  • Sensibilitat del sensor massa alta.
  • Relocate heat sources or adjust sensor placement.
  • Reduce sensor sensitivity.

If problems persist after attempting these solutions, contact Lutron Technical Support.

7. Especificacions

  • Número de model: MS-OPS2H-WH
  • Marca: Lutron
  • Color: Blanc
  • Font d'alimentació: Elèctric amb cable
  • Tipus de muntatge: Muntatge de paret
  • Dimensions del producte: 5.8 x 3.8 x 2 polzades
  • Pes de l'article: 1.28 unces
  • Temperatura de funcionament: 68 graus Fahrenheit (20 graus Celsius)
  • Dispositius compatibles: Lluminàries
  • UPC: 027557983136

8. Garantia i Suport

Lutron products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Lutron website. For technical assistance, troubleshooting, or product inquiries, please contact Lutron Customer Service.

Lutron Customer Service:

  • Visita www.lutron.com/support per als recursos en línia.
  • Contact information for phone support can be found on the Lutron weblloc.