1. Producte acabatview
The Cisco Nexus 93180YC-EX is a high-performance, fixed-configuration switch designed for data center deployments. It offers advanced Layer 2 and Layer 3 capabilities, supporting high-density 10/25 Gigabit Ethernet SFP+ and 40/100 Gigabit Ethernet QSFP+ connectivity. This manual provides essential information for the installation, operation, and maintenance of your Cisco Nexus 93180YC-EX switch.

Figura 1: Frontal view of the Cisco Nexus 93180YC-EX Switch, showing 48 SFP+ ports and 6 QSFP+ ports.
Les característiques clau inclouen:
- High-Density Connectivity: 48 fixed 10/25-Gbps SFP+ ports and 6 fixed 40/100-Gbps QSFP+ ports.
- Latència baixa: Cut-through switching architecture with less than 1 microsecond latency.
- Network Virtualization: Support for Virtual Extensible LAN (VXLAN).
- Automation and Management: Integration with Cisco Application Centric Infrastructure (ACI).
- Alta disponibilitat: Hot-swappable power supplies and fans.
- Sistema operatiu: Runs on Cisco NX-OS.
2. Configuració i instal·lació
This section outlines the steps for physically installing and initially connecting your switch.
2.1. Desembalatge i inspecció
Carefully unpack the switch and all accessories. Inspect the components for any signs of damage. If any damage is found, contact your vendor immediately.
2.2. Muntatge en bastidor
The Cisco Nexus 93180YC-EX is designed for standard 19-inch rack mounting. Use the provided rack-mount kit to secure the switch in the rack. Ensure adequate clearance for airflow at the front and rear of the unit.
- Attach the mounting brackets to the sides of the switch.
- Align the switch with the rack posts and secure it using the appropriate screws.
2.3. Connexió d'alimentació
The switch supports redundant hot-swappable AC/DC power supplies. Connect the power cables to the power supply modules and then to a grounded power outlet. For redundancy, connect each power supply to an independent power source.
- Insert the power supply modules into their respective bays.
- Connect the power cords to the power supply modules.
- Plug the power cords into appropriate power sources.
2.4. Connexió de xarxa inicial
For initial configuration, connect a console cable to the RJ-45 console management port on the switch and to a terminal emulator on a computer.
- Connect a console cable to the console port.
- Configure your terminal emulator with the following settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.
- Enceneu l'interruptor.
- Seguiu les indicacions de la pantalla per a la configuració inicial.
Alternatively, you can use the 10/100/1000 Ethernet management port for out-of-band management after initial IP configuration.
3. Funcionament de l'interruptor
The Cisco Nexus 93180YC-EX operates on Cisco NX-OS, providing a robust and feature-rich environment for network management.
3.1. Cisco NX-OS Overview
Cisco NX-OS is a purpose-built operating system designed for data center environments. It offers modularity, high availability, and a comprehensive set of features for Layer 2 and Layer 3 networking, security, and storage networking.
Refer to the official Cisco NX-OS documentation for detailed command-line interface (CLI) instructions and configuration guides.
3.2. Port Configuration
The switch features 48 SFP+ ports (supporting 1/10/25 Gbps) and 6 QSFP+ ports (supporting 40/100 Gbps). These ports can be configured for various network roles, including access, trunk, and routed ports.
- Ports SFP+: Use appropriate SFP, SFP+, or SFP28 transceivers for 1, 10, or 25 Gigabit Ethernet connections.
- QSFP+ Ports: Use QSFP+ or QSFP28 transceivers for 40 or 100 Gigabit Ethernet connections. These ports can often be broken out into multiple lower-speed interfaces (e.g., 4x10G or 4x25G) depending on the transceiver and configuration.
Ensure that compatible transceivers and cables are used for optimal performance and connectivity.
3.3. Funcions avançades
The switch supports advanced features crucial for modern data centers:
- VXLAN: Virtual Extensible LAN provides network virtualization over Layer 3 infrastructure, enabling scalable multi-tenant environments.
- Cisco ACI: Cisco Application Centric Infrastructure offers a software-defined networking (SDN) solution for automated network provisioning and management based on application requirements.
4. Manteniment
Regular maintenance ensures the longevity and optimal performance of your Cisco Nexus 93180YC-EX switch.
4.1. Hot-Swappable Components
The switch is designed with hot-swappable components to minimize downtime:
- Fonts d'alimentació: Power supply modules can be replaced without powering down the switch, provided at least one other power supply is operational.
- Mòduls de ventilador: Fan modules can also be replaced while the switch is operational.
Always refer to the official Cisco documentation for specific procedures on replacing these components.
4.2. Actualitzacions de firmware i programari
Periodically check the Cisco support website for the latest NX-OS software releases and firmware updates. Keeping your software up-to-date ensures access to new features, performance enhancements, and security patches. Follow Cisco's recommended upgrade procedures carefully.
4.3. Consideracions ambientals
Maintain the operating environment within the specified ranges for temperature and humidity. Ensure proper airflow around the switch to prevent overheating. Regularly inspect and clean air filters if present, and ensure no obstructions block ventilation openings.
5. Solució De Problemes
Aquesta secció proporciona els passos bàsics per a la resolució de problemes comuns.
5.1. Problemes d'energia
- Sense energia: Verify that power cables are securely connected to both the switch and the power source. Check power supply LEDs for status.
- Power Supply Failure: If a power supply LED indicates a fault, replace the faulty module.
5.2. Problemes de connectivitat
- Port Link Down: Check the cable connection, transceiver type, and link status LEDs on the port. Verify configuration on both ends of the link.
- No Network Access: Verify IP configuration, VLAN assignments, and routing tables. Use CLI commands like
show interface,show ip route, ipingto diagnose.
5.3. Indicadors d'estat del sistema
The switch features various LEDs to indicate system status. Consult the official Cisco documentation for a detailed explanation of each LED's behavior (e.g., System LED, Fan LED, Power Supply LEDs, Port Status LEDs).
5.4. Contactant amb el suport
If you encounter issues that cannot be resolved using this manual or official Cisco documentation, contact Cisco Technical Assistance Center (TAC) for further assistance. Provide your product serial number and a detailed description of the problem.
6. Especificacions tècniques
| Característica | Especificació |
|---|---|
| Número de model | N9K-C93180YC-EX |
| Ports | 48 fixed 10/25-Gbps SFP+ ports, 6 fixed 40/100-Gbps QSFP28 ports |
| Capacitat de commutació | 3.6 Tbps |
| Taxa de reenviament | 2.67 bpps |
| Latència | Menys d'1 microsegon |
| Suport de marc jumbo | Fins a 9216 bytes |
| MTBF | 299,215 hores |
| Font d'alimentació | 2 hot-swappable redundant AC/DC power supplies (up to 1200W each) |
| Fans | 4 hot-swappable redundant fans |
| Sistema operatiu | Cisco NX-OS |
| Interfícies de gestió | 1 RJ-45 console, 1 USB, 1 10/100/1000 Ethernet management port |
| Dimensions (A x A x P) | 1.72 x 17.3 x 22.5 polzades |
| Pes | 24.7 lliures (11.2 kg) |
7. Garantia i Suport
Cisco products typically come with a limited hardware warranty. For specific warranty terms and conditions applicable to your Cisco Nexus 93180YC-EX switch, please refer to the warranty information provided with your purchase or visit the official Cisco weblloc.
For technical support, software downloads, and documentation, visit the Suport de Cisco Weblloc. You will need your product serial number to access certain support resources.





