1. Introducció
This user manual provides essential information for the safe and efficient operation, installation, and maintenance of the Danfoss EV220B 032U7520 Solenoid Valve. Please read this manual thoroughly before installation or operation to ensure proper use and to prevent damage or injury.
2. Informació de seguretat
Always observe general safety precautions during installation, operation, and maintenance. Failure to follow these instructions may result in serious injury or property damage.
- Ensure power is disconnected before any installation or maintenance work.
- Only qualified personnel should perform installation and service.
- Verify that the valve's specifications match the system requirements (pressure, temperature, medium).
- Protect the valve from physical damage and extreme environmental conditions.
3. Descripció del producte
The Danfoss EV220B 032U7520 is a robust 2/2-way servo-operated solenoid valve designed for use in various industrial applications. It features a 1/2 inch NPT connection and is suitable for neutral media. The valve is constructed from durable metal, ensuring long-term reliability.

Figura 3.1: Danfoss EV220B 032U7520 Solenoid Valve. This image shows the brass body of the valve with a threaded inlet/outlet and the cylindrical solenoid coil assembly extending upwards from the top.
Característiques principals:
- Model: 032U7520
- Mida de la connexió: 1/2 polzada NPT
- Tipus de vàlvula: 2/2-way, servo-operated
- Material: Metal (Brass body)
- Aplicació: Suitable for neutral media
4. Configuració i instal·lació
Proper installation is crucial for the valve's performance and longevity. Follow these steps carefully:
- Preparació:
- Ensure the system is depressurized and drained.
- Clean the pipe threads to remove any debris or sealant residue.
- Verify that the flow direction arrow on the valve body matches the system flow.
- Muntatge:
- Mount the valve in a position where it is easily accessible for maintenance.
- The valve can be mounted in any position, but mounting with the coil upwards is recommended for optimal performance and lifespan.
- Use appropriate thread sealant on the NPT connections.
- Tighten the valve securely into the piping system, avoiding overtightening which can damage the threads or valve body.
- Connexió elèctrica:
- Connect the solenoid coil to the appropriate power supply as specified on the coil label.
- Assegureu-vos que totes les connexions elèctriques estiguin ben segudes i aïllades per evitar curtcircuits.
- Compliu els codis elèctrics i les normatives locals.
- Comprovació del sistema:
- After installation, slowly pressurize the system and check for leaks.
- Test the valve's operation by applying and removing power to the coil.
5. Instruccions de funcionament
The Danfoss EV220B 032U7520 is a normally closed (NC) solenoid valve, meaning it is closed when de-energized and opens when energized.
- Energitzant la bobina: When electrical power is supplied to the solenoid coil, it creates a magnetic field that pulls the plunger, opening the valve and allowing fluid to flow.
- Desactivació de l'alimentació de la bobina: When power is removed from the coil, the magnetic field collapses, and a spring forces the plunger back to its original position, closing the valve and stopping fluid flow.
- Accionament manual (si escau): Some models may feature a manual override. Refer to specific product documentation if a manual override is present and how to use it safely. This model typically does not include a manual override.
Assegureu-vos que el vol operatiutage and frequency match the coil's specifications to prevent damage and ensure proper function.
6. Manteniment
Regular maintenance ensures optimal performance and extends the lifespan of your solenoid valve. Always disconnect power before performing any maintenance.
- Neteja: Periodically inspect the valve for dirt, debris, or corrosion. Clean the exterior with a soft, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
- Comprovació de fuites: Regularly check all connections for signs of leaks. Tighten connections if necessary, but do not overtighten.
- Inspecció de la bobina: Inspect the solenoid coil for any signs of damage, overheating, or discoloration. Replace the coil if any damage is observed.
- Internal Inspection (Advanced): For internal component inspection or replacement (e.g., diaphragm, plunger), it is recommended to consult a qualified technician or refer to detailed service manuals provided by Danfoss. Ensure the system is fully depressurized and drained before opening the valve.
7. Solució De Problemes
This section provides solutions to common issues. For problems not listed here, contact Danfoss technical support.
| Problema | Causa possible | Solució |
|---|---|---|
| Valve does not open when energized. |
|
|
| Valve does not close when de-energized. |
|
|
| Leakage from connections. |
|
|
8. Especificacions
Detailed technical specifications for the Danfoss EV220B 032U7520 Solenoid Valve:
- Número de model: 032U7520
- Número de peça: G032U7520
- Tipus de vàlvula: 2/2-way, Servo-operated, Normally Closed (NC)
- Mida de la connexió: 0.5 Inches NPT (National Pipe Tapered)
- Nombre de ports: 2
- Material: Metal (Brass body)
- Pes de l'article: Approximately 11 ounces (0.69 LBR)
- Dimensions del producte (L x A x A): 2.5 x 3.75 x 2.13 polzades
- UPC-EAN: 5702423044412
- Fabricant: Danfoss
- Primer disponible: 14 de desembre de 2016
9. Garantia i Suport
For specific warranty information regarding the Danfoss EV220B 032U7520 Solenoid Valve, please refer to the documentation provided with your purchase or visit the official Danfoss weblloc. Els termes de la garantia solen cobrir els defectes de fabricació durant un període especificat.
For technical support, service, or spare parts, please contact your authorized Danfoss distributor or visit the Danfoss global support portal. Provide the model number (032U7520) and serial number (if applicable) when seeking support.
Danfoss Oficial Weblloc: www.danfoss.com