1. Introducció

This manual provides essential information for the proper installation, operation, and maintenance of the AKO D-14323 230V Universal Digital Temperature Controller. Designed for industrial and commercial refrigeration applications, this controller offers precise temperature management and adjustable defrost cycles. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Informació de seguretat

Observeu sempre les següents precaucions de seguretat per evitar lesions personals o danys al dispositiu:

  • La instal·lació i el manteniment només els ha de dur a terme personal qualificat.
  • Disconnect power to the unit before performing any wiring or maintenance.
  • Assegureu-vos que la font d'alimentació voltage matches the controller's specifications (230V).
  • Protect the device from water, moisture, and extreme temperatures.
  • Do not open the controller housing unless specifically instructed.

3. Producte acabatview

The AKO D-14323 is a versatile digital temperature controller equipped with a clear digital display and intuitive controls. It is suitable for a wide range of refrigeration and freezer units.

Característiques principals:

  • Digital thermostat for industrial and commercial freezers.
  • Temperature range from -50.0 °C to +99.9 °C (-58°F to +210.2°F).
  • Three relays for compressor, fan, and auxiliary functions.
  • Two temperature sensors included.
  • Panel mounting design.
  • Programmable defrost cycles.
  • Fahrenheit and Celsius readings.
  • Programmable digital inputs for door switch, alarm, remote defrost, energy saving, or continuous cycle.

Controller Front Panel:

Davant view of AKO D-14323 Temperature Controller

Imatge 3.1: Davant view of the AKO D-14323 controller, showing the digital display and control buttons. The display shows temperature readings, and buttons include ESC, SET, Power, and up/down arrows (often used for defrost and parameter adjustment).

The front panel features a digital display for temperature readings and status indicators. Control buttons allow for setting parameters, initiating defrost cycles, and navigating menus.

4. Instal·lació i configuració

Proper installation is crucial for the controller's performance and longevity.

4.1 Muntatge en panell

The AKO D-14323 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals.

4.2 Connexions elèctriques

Refer to the wiring diagram on the back of the unit for correct electrical connections. All wiring must comply with local electrical codes.

Enrere view of AKO D-14323 Temperature Controller with wiring diagram

Imatge 4.1: Enrere view of the AKO D-14323 controller, displaying the wiring diagram and product specifications. This diagram illustrates connections for power (230V), sensors (S1, S2), compressor (COOL), fan, and auxiliary outputs, along with digital inputs (D1, D2).

Wiring Key Points:

  • Font d'alimentació: Connect 230V AC to the designated terminals.
  • Sensors: Connect the two temperature sensors (S1, S2) to their respective terminals.
  • Sortides de relé: Connect the compressor, fan, and auxiliary loads to their corresponding relay terminals. The diagram specifies maximum current ratings for each output (e.g., COOL: 12(9)A 250V~, FAN: 5(4)A 250V~, AUX: 8(4)A 250V~).
  • Entrades digitals: Utilize terminals for programmable digital inputs such as door switches or external alarms.

4.3 Engegada inicial

After wiring, apply power to the controller. The display should illuminate, showing the current temperature or an initial setup prompt.

5. Instruccions de funcionament

The AKO D-14323 offers various programmable parameters to suit different refrigeration needs.

5.1 Funcionament bàsic

  • Visualització de la temperatura: The main display shows the current temperature measured by the primary sensor.
  • Botó SET: Premeu per view or modify the setpoint temperature. Hold to enter parameter programming mode.
  • Botó ESC: Used to exit menus or cancel changes.
  • Fletxes amunt/avall: Used to adjust values in programming mode or manually initiate defrost (if configured).
  • Botó d'encesa: Turns the unit on/off or acts as a reset in some configurations.

5.2 Configuració del punt de consigna de temperatura

  1. Premeu el botó SET button briefly. The current setpoint will flash.
  2. Utilitza el Up or Avall botons de fletxa per ajustar la temperatura desitjada.
  3. Premeu SET again to confirm and save the new setpoint, or ESC per sortir sense desar.

5.3 Advanced Parameter Programming

To access advanced parameters (e.g., defrost cycles, differential, auxiliary relay functions), hold the SET button for several seconds until the first parameter code appears. Navigate using the arrow buttons and press SET to enter/confirm values. Refer to the detailed programming guide (usually provided separately or available from AKO) for a complete list of parameters and their functions.

5.4 Defrost Cycle Management

The controller supports various defrost methods, including controlling the compressor, resistance heaters, or fans. Defrost parameters can be adjusted to optimize performance based on the application. An optional probe allows defrosting by temperature.

6. Manteniment

Un manteniment regular garanteix un rendiment òptim i allarga la vida útil del controlador de temperatura.

  • Neteja: Periodically clean the front panel with a soft, damp tela. No utilitzeu netejadors abrasius ni dissolvents.
  • Inspeccions: Regularly check wiring connections for tightness and signs of wear or corrosion.
  • Comprovació del sensor: Ensure temperature sensors are securely in place and free from damage.

For any internal maintenance or repairs, contact a qualified technician.

7. Solució De Problemes

If you encounter issues with your AKO D-14323 controller, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
La pantalla està en blancSense subministrament d'alimentació; cablejat incorrecteCheck power connections and ensure 230V supply. Verify wiring according to the diagram.
Lectura de temperatura incorrectaFaulty sensor; sensor not properly connected or placedCheck sensor connections. Replace sensor if damaged. Ensure sensor is correctly positioned in the controlled environment.
Compressor/Fan not operatingSetpoint issue; relay fault; wiring error; parameter misconfigurationVerify setpoint and differential settings. Check wiring to the compressor/fan. Review advanced parameters for correct configuration.
Defrost not initiatingDefrost parameters incorrect; manual defrost not triggeredCheck defrost cycle settings (interval, duration, temperature). Attempt manual defrost if configured.

If the problem persists after attempting these solutions, contact AKO technical support or a qualified service technician.

8. Especificacions

Detailed technical specifications for the AKO D-14323 controller:

  • Model: AKO D-14323
  • Voltage: 230 Volts
  • Interval de temperatura: -50.0 °C to +99.9 °C (-58°F to +210.2°F)
  • Relleus: 3 (Compressor, Fan, Auxiliary)
  • Sensors: 2 temperature sensors included
  • Muntatge: Muntatge en panell
  • Material: Plàstic
  • Pes de l'article: 0.01 unces (aproximadament)
  • Estil de visualització: Digital
  • Característiques especials: Programable
  • Ús: Comercial/Residencial
  • Certificacions: ETL, CE, IP65, GAMA
  • Fabricant: AKOCONTROL

9. Garantia i Suport

For warranty information and technical support, please contact AKO directly or refer to their official weblloc. Conserveu el rebut de compra per a reclamacions de garantia.

Fabricant: AKOCONTROL
Weblloc: www.ako.com

Documents relacionats - D-14323

Preview Controlador de temperatura AKO amb fins a tres relés i dues sondes manual
This document provides detailed information on AKO temperature controllers, including versions, technical data, installation, front panel functions, adjustment, parameters, and maintenance. It covers models like AKO-14212, AKO-14220, AKO-14223, AKO-14312, AKO-14320, and AKO-14323.
Preview AKO PROCool Electronic Control Unit - User Manual
Comprehensive user manual for the AKO PROCool electronic control unit, detailing installation, operation, configuration, parameters, and technical specifications for refrigeration systems.
Preview AKO 1301H201: Termómetros, Termostatos y Controladores Electrónicos de Temperatura
Hoja tècnica detallada per als controladors de temperatura AKO serie 1301H201, incloent especificacions, instal·lació, configuració de paràmetres i manteniment. Ideal per a aplicacions de refrigeració i calefacció.
Preview AKO Multi-Sensor Electronic Thermostats: Technical Specification
Detailed technical specification for AKO multi-sensor electronic thermostats, covering features, installation, parameters, and operation for models AKO-1472x and AKO-1522x. Includes relay configurations, alarm settings, and digital input options.
Preview Manual d'usuari del controlador de temperatura i registre de dades AKO-15724/AKO-15725
Manual d'usuari complet per als controladors de temperatura i registradors de dades AKO-15724 i AKO-15725, que detalla la instal·lació, el funcionament, les especificacions tècniques i la programació.
Preview Controladors de temperatura de la sèrie AKO D14xxx / D101xx: manual tècnic i especificacions
Manual tècnic detallat i especificacions per als controladors de temperatura de les sèries AKO D14xxx, D101xx, D141xx i D140xx. Inclou avisos, funcionament, diagrames de cablejat, assistent d'engegada, accessoris i dades tècniques.