1. Producte acabatview
The Myers HJ50D is a convertible deep water well jet pump designed for reliable water supply from deep well applications. This 1/2 HP pump operates on either 115V or 230V, providing versatility for various electrical setups. It is engineered for efficient performance in residential and light commercial water systems.
- Deep Water Well Jet Pump functionality.
- 1/2 Horsepower motor for effective water transfer.
- Vol dobletage operation: 115V or 230V.

An image showing the Myers HJ50D Convertible Deep Water Well Jet Pump, a green-colored unit with a motor on one end and the pump housing with inlet/outlet ports on the other. This pump is designed for deep well applications.
2. Informació de seguretat
Read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions can result in serious injury, death, or property damage.
- Risc elèctric: Always disconnect power before servicing the pump. Ensure proper grounding and wiring according to local electrical codes.
- Perill de pressió: Water systems operate under pressure. Relieve system pressure before servicing.
- Parts mòbils: Mantingueu les mans i la roba allunyades de les parts mòbils durant el funcionament.
- Superfícies calentes: The pump motor can become hot during operation. Allow it to cool before handling.
- Personal qualificat: Installation and electrical connections should only be performed by qualified personnel.
3. Configuració i instal·lació
3.1 Comprovacions prèvies a la instal·lació
- Verify the power supply matches the pump's voltage requirements (115V or 230V).
- Ensure the well casing is clean and free of debris.
- Confirm adequate space for pump installation and future maintenance.
3.2 Muntatge de la bomba
Mount the pump on a firm, level foundation to minimize vibration. Use appropriate bolts and washers to secure the pump base. Ensure the pump is as close to the well as practical to reduce suction lift.
3.3 Connexions de fontaneria
- Connect the suction line from the well to the pump's suction port. Ensure all connections are airtight to prevent air leaks.
- Connect the discharge line from the pump to the pressure tank and distribution system.
- Install a check valve in the suction line if not already present in the jet assembly.
- Install a pressure gauge and pressure switch on the discharge side.
3.4 Cablejat elèctric
Wire the pump according to the wiring diagram provided on the motor nameplate and local electrical codes. Ensure the correct voltage selection (115V or 230V) is made before connecting power. The pump must be properly grounded.
3.5 Cebament de la bomba
Before initial startup, the pump casing and suction line must be completely filled with water. Remove the priming plug, slowly fill the pump with water until it overflows, then replace the plug securely. This process removes air from the pump, allowing it to create suction.
4. Instruccions de funcionament
4.1 Inici inicial
- Ensure the pump is properly primed as described in Section 3.5.
- Open a faucet in the system to allow air to escape.
- Restore power to the pump. The pump should start and begin to draw water.
- Once a steady stream of water flows from the faucet, close the faucet. The pump will build pressure and shut off when the pressure switch setting is reached.
4.2 Funcionament normal
The pump will automatically cycle on and off based on the pressure switch settings, maintaining system pressure as water is used. Monitor the pressure gauge periodically to ensure proper operation.
4.3 Apagat de la bomba
To temporarily or permanently shut down the pump, disconnect the electrical power supply at the circuit breaker or fuse box. If shutting down for an extended period or for winterization, refer to the maintenance section.
5. Manteniment
Regular maintenance ensures the longevity and efficient operation of your Myers HJ50D pump. Always disconnect power before performing any maintenance.
5.1 Inspecció periòdica
- Check for leaks around plumbing connections.
- Inspect electrical wiring for signs of wear or damage.
- Presteu atenció a sorolls inusuals durant el funcionament, que podrien indicar un problema.
- Verify the pressure switch is operating correctly and maintaining desired pressure.
5.2 Hivernització
In areas subject to freezing temperatures, the pump and associated piping must be drained to prevent damage. Disconnect power, open drain plugs on the pump and any exposed piping, and allow all water to drain completely. Store the pump in a warm, dry place if possible, or ensure it is thoroughly drained and protected from freezing.
6. Solució De Problemes
This section provides solutions to common operational issues. For problems not listed or if solutions do not resolve the issue, contact a qualified service technician.
| Problema | Causa possible | Solució |
|---|---|---|
| La bomba no arrenca. | No power; tripped circuit breaker; faulty pressure switch; motor issue. | Comproveu el subministrament elèctric; reinicieu l'interruptor; inspeccioneu/substituïu el pressostat; consulteu un tècnic. |
| Pump runs but delivers no water. | Pump not primed; air leak in suction line; low water level in well; clogged foot valve. | Re-prime pump; check suction line connections; verify well water level; inspect/clean foot valve. |
| Baixa pressió d'aigua. | Partially clogged lines; worn pump components; pressure switch setting too low; air in system. | Inspect/clean lines; service pump; adjust pressure switch; bleed air from system. |
| La bomba funciona contínuament. | Leak in system; faulty pressure switch; pump unable to build pressure. | Check for leaks; inspect/replace pressure switch; troubleshoot for no water/low pressure issues. |
7. Especificacions
| Atribut | Detall |
|---|---|
| Marca | Myers |
| Número de model | HJ50D |
| Número de part | HR50D |
| Potència (HP) | 1 / 2 HP |
| Voltage | 115V/230V |
| Font d'alimentació | AC/DC |
| Pes de l'article | 44 lliures |
| Estil | Convertible Deep Water Well Jet Pump |
| UPC | 713356111732 |
8. Garantia i Suport
For detailed warranty information, please refer to the warranty card included with your product or visit the official Myers weblloc web. Conserveu el rebut de compra com a comprovant de compra per a reclamacions de garantia.
For technical support, replacement parts, or service inquiries, please contact Myers customer service. Contact details can typically be found on the manufacturer's weblloc o a l'embalatge del producte.