Reznor 96307

Reznor 96307 1/2-inch Spark Gas Valve User Manual

1. Introducció

This user manual provides essential information for the safe and efficient installation, operation, and maintenance of the Reznor 96307 1/2-inch Spark Gas Valve. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent potential hazards. Retain this manual for future reference.

2. Informació de seguretat

Your safety and the safety of others are paramount. This gas valve must be installed and serviced by a qualified technician in accordance with all local codes and regulations. Failure to follow these instructions could result in property damage, personal injury, or death.

WARNING: EXPLOSION HAZARD. Severe Injury or Death Can Result.

  • Do not take valve apart.
  • Do not use tools to operate valve.
  • Do not use valve if it has been flooded.
  • Call a qualified serviceman if the valve does not work properly.

Part Number: 394606 Rev. U

Reznor 96307 1/2-inch Spark Gas Valve with warning label
Figure 1: Reznor 96307 1/2-inch Spark Gas Valve. The image shows the gas valve assembly, a metallic unit with various ports and an electrical connection. A prominent yellow warning label is visible on the top section, detailing explosion hazards and safety precautions.

3. Descripció del producte

The Reznor 96307 is a 1/2-inch spark gas valve designed for controlling gas flow in compatible heating systems. This component is crucial for the safe and regulated delivery of gas to the burner, ensuring reliable ignition and operation. It is manufactured by Reznor, a reputable brand known for HVAC components.

4. Especificacions

CaracterísticaDetall
FabricantReznor
Número de part96307
Pes de l'article2.08 unces
Quantitat de paquet d'articles1
Necessites piles?No
ASINB06XXC2SHN
Primera data disponible10 de desembre de 2017

5. Instal·lació (Configuració)

Important: Installation must be performed by a qualified and licensed professional. Incorrect installation can lead to gas leaks, fire, explosion, or carbon monoxide poisoning.

  1. La seguretat primer: Ensure the main gas supply to the appliance is turned off and verified before beginning any work. Disconnect electrical power to the appliance.
  2. Àrea de preparació: Clear the work area and ensure adequate ventilation.
  3. Remove Old Valve (if applicable): Carefully disconnect and remove the existing gas valve, noting all connections (gas lines, electrical wiring).
  4. Inspect New Valve: Visually inspect the Reznor 96307 valve for any signs of damage.
  5. Connect Gas Lines: Apply appropriate pipe sealant (suitable for gas) to threaded connections. Connect the gas inlet and outlet lines to the valve, ensuring a tight, leak-free seal. Do not overtighten.
  6. Connecteu el cablejat elèctric: Connect the electrical wiring to the valve terminals as per the appliance manufacturer's wiring diagram. Ensure all connections are secure.
  7. Prova de fuites: After all connections are made, slowly turn on the main gas supply. Perform a leak test using a soap solution on all gas connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately and tighten connections until no leaks are present.
  8. Restaura l'alimentació: Once leak testing is complete and no leaks are found, restore electrical power to the appliance.
  9. Prova de funcionament: Follow the appliance manufacturer's instructions to test the operation of the gas valve and the appliance.

6. Funcionament

The Reznor 96307 gas valve operates in conjunction with your heating appliance's control system. It is designed to open and close automatically to regulate gas flow to the burner based on demand.

  • Funcionament normal: When the appliance calls for heat, the control system sends a signal to the gas valve. The valve opens, allowing gas to flow to the burner, where it is ignited by the spark igniter.
  • Apagada de seguretat: In the event of an ignition failure or other safety condition detected by the appliance's control system, the gas valve will automatically close to prevent uncombusted gas from accumulating.
  • Anulació manual: This valve does not feature a user-serviceable manual override. Any operation or adjustment must be done through the appliance's control system or by a qualified technician. Refer to the appliance's user manual for specific operational instructions.

7. Manteniment

The Reznor 96307 gas valve is a sealed unit and generally requires no routine user maintenance. However, periodic inspection by a qualified technician is recommended as part of overall appliance maintenance.

  • Inspecció anual: Feu que un tècnic qualificat inspeccioni la vàlvula de gas i totes les connexions de gas anualment per detectar signes de desgast, corrosió o fuites.
  • Neteja: Ensure the area around the gas valve is kept clean and free from dust, debris, or obstructions that could impede its function or ventilation.
  • No lubricar: Do not attempt to lubricate or disassemble the gas valve. This can damage the unit and create a safety hazard.

8. Solució De Problemes

If you experience issues with your heating appliance that you suspect are related to the gas valve, consult the troubleshooting section of your appliance's user manual first. If the problem persists, contact a qualified service technician. Do not attempt to repair the gas valve yourself.

ProblemaCausa possibleAcció
No hi ha flux de gas al cremadorGas supply off, valve malfunction, control system issueCheck main gas supply. Verify appliance control settings. If problem persists, contact a qualified technician.
S'ha detectat una olor de gasFuita de gasImmediately turn off gas supply. Open windows. Do not operate electrical switches. Evacuate premises and call emergency services and a qualified gas technician.
Valve not opening/closing properlyElectrical issue, internal valve faultContact a qualified service technician for diagnosis and repair.

9. Informació de la garantia

Specific warranty details for the Reznor 96307 1/2-inch Spark Gas Valve are typically provided by the manufacturer or the seller at the time of purchase. Please refer to your purchase documentation or contact Reznor directly for comprehensive warranty terms and conditions. This manual does not constitute a warranty statement.

10. Suport i contacte

For technical assistance, service, or to inquire about replacement parts for your Reznor 96307 1/2-inch Spark Gas Valve, please contact Reznor customer support or your authorized Reznor dealer. Always provide the model number (96307) and any relevant appliance information when seeking support.

Fabricant: Reznor

(Contact information such as phone numbers or weblloc URLs are not provided in the product data and should be obtained from official Reznor sources.)

Documents relacionats - 96307

Preview Guia de peces de recanvi Reznor: sistemes d'encesa i vàlvules de gas
Guia completa per a propietaris i tècnics d'equips de calefacció Reznor sobre la selecció de controladors d'encesa de recanvi, vàlvules de gas i components Maxitrol mitjançant números de sèrie i de model. Inclou pautes de seguretat i identificació de peces.
Preview Guia d'instal·lació del kit de vàlvula de gas de recanvi Reznor per a escalfadors M8, U8, U9
Instruccions d'instal·lació pas a pas per al kit de vàlvula de gas de recanvi Reznor (PN 221634) per a escalfadors de les sèries M8, U8 i U9. Inclou avisos de seguretat i detalls dels components.
Preview Guia de peces de recanvi de Reznor: sistemes d'encesa, vàlvules de gas i components Maxitrol
Una guia completa de Reznor que detalla les peces de recanvi per a sistemes d'encesa, vàlvules de gas i components de modulació electrònica Maxitrol. Inclou la descodificació del número de sèrie, explicacions del número de model, avisos de seguretat i instruccions de selecció de peces.
Preview Reznor Unit Heater Replacement Parts Catalog
Comprehensive catalog of replacement parts for Reznor APD, UDAP, UDBP, UDAS, and UDBS unit heaters, detailing electrical, blower, cabinet, venter, and burner assembly components, as well as various accessories and options.
Preview Reznor Replacement Parts Manual: Ignition Systems & Gas Valves
Comprehensive guide for identifying and selecting replacement ignition controllers, gas valves, and Maxitrol system components for Reznor industrial heating equipment. Features serial number decoding, part cross-references, and safety guidelines.
Preview Catàleg de peces de recanvi Reznor: Sistemes d'encesa i vàlvules de gas
Guia completa de les peces de recanvi Reznor, incloent-hi sistemes d'encesa, vàlvules de gas i components Maxitrol. Inclou descodificació del número de sèrie i instruccions de selecció per a tècnics de servei.